Search
Find a vulnerability
Search criteria
58 vulnerabilities found for PowerScale InsightIQ by Dell
CVE-2026-116433 (GCVE-0-2026-116433)
Vulnerability from nvd – Published: 2026-11-13 09:16 – Updated: 2026-11-17 13:12
VLAI
EPSS
VEX
Summary
Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains a Missing Authorization vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Unauthorized access.
Severity
4.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-17 13:12 UTC
CWE
- CWE-862 - Missing Authorization
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-gb/00052893… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale InsightIQ |
Affected:
0 , < 6.4.1 or later
(semver)
|
Date Public
2026-11-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-116433",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-17T13:12:30.156022Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-17T13:12:46.010Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-11-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains a Missing Authorization vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Unauthorized access."
}
],
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains a Missing Authorization vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Unauthorized access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-862",
"description": "CWE-862: Missing Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T09:16:36.792Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-gb/000528934/dsa-2026-480-security-update-for-dell-powerscale-insightiq-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-116433",
"datePublished": "2026-11-13T09:16:36.792Z",
"dateReserved": "2026-10-26T10:04:27.244Z",
"dateUpdated": "2026-11-17T13:12:46.010Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-116418 (GCVE-0-2026-116418)
Vulnerability from nvd – Published: 2026-11-13 09:20 – Updated: 2026-11-13 16:02
VLAI
EPSS
VEX
Summary
Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains an Incorrect Authorization vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-13 15:34 UTC
CWE
- CWE-863 - Incorrect Authorization
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-gb/00052893… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale InsightIQ |
Affected:
0 , < 6.4.1 or later
(semver)
|
Date Public
2026-11-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-116418",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-13T15:34:56.742807Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T16:02:31.981Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-11-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains an Incorrect Authorization vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains an Incorrect Authorization vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-863",
"description": "CWE-863: Incorrect Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T09:20:16.351Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-gb/000528934/dsa-2026-480-security-update-for-dell-powerscale-insightiq-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-116418",
"datePublished": "2026-11-13T09:20:16.351Z",
"dateReserved": "2026-10-26T10:04:27.243Z",
"dateUpdated": "2026-11-13T16:02:31.981Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-116453 (GCVE-0-2026-116453)
Vulnerability from nvd – Published: 2026-11-13 08:45 – Updated: 2026-11-13 17:47
VLAI
EPSS
VEX
Summary
Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains a Missing Authorization vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information tampering and Unauthorized access.
Severity
5.4 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-13 17:47 UTC
CWE
- CWE-862 - Missing Authorization
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-gb/00052893… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale InsightIQ |
Affected:
0 , < 6.4.1 or later
(semver)
|
Date Public
2026-11-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-116453",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-13T17:47:06.281521Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T17:47:26.001Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-11-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains a Missing Authorization vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information tampering and Unauthorized access."
}
],
"value": "Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains a Missing Authorization vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information tampering and Unauthorized access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-862",
"description": "CWE-862: Missing Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T08:45:39.033Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-gb/000528934/dsa-2026-480-security-update-for-dell-powerscale-insightiq-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-116453",
"datePublished": "2026-11-13T08:45:39.033Z",
"dateReserved": "2026-10-26T10:04:27.247Z",
"dateUpdated": "2026-11-13T17:47:26.001Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-116438 (GCVE-0-2026-116438)
Vulnerability from nvd – Published: 2026-11-13 08:32 – Updated: 2026-11-17 17:16
VLAI
EPSS
VEX
Summary
Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0 , contains a Missing Authorization vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Denial of service.
Severity
5.4 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-17 17:11 UTC
CWE
- CWE-862 - Missing Authorization
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-gb/00052893… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale InsightIQ |
Affected:
0 , < 6.4.1 or later
(semver)
|
Date Public
2026-11-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-116438",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-17T17:11:19.723874Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-17T17:16:55.745Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-11-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0 , contains a Missing Authorization vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Denial of service."
}
],
"value": "Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0 , contains a Missing Authorization vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Denial of service."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-862",
"description": "CWE-862: Missing Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T08:32:58.575Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-gb/000528934/dsa-2026-480-security-update-for-dell-powerscale-insightiq-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-116438",
"datePublished": "2026-11-13T08:32:58.575Z",
"dateReserved": "2026-10-26T10:04:27.245Z",
"dateUpdated": "2026-11-17T17:16:55.745Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-116436 (GCVE-0-2026-116436)
Vulnerability from nvd – Published: 2026-11-13 08:12 – Updated: 2026-11-17 13:10
VLAI
EPSS
VEX
Summary
Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Unauthorized access.
Severity
4.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-17 13:10 UTC
CWE
- CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-gb/00052893… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale InsightIQ |
Affected:
0 , < 6.4.1 or later
(semver)
|
Date Public
2026-11-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-116436",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-17T13:10:07.551179Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-17T13:10:27.634Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-11-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Unauthorized access."
}
],
"value": "Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Unauthorized access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532: Insertion of Sensitive Information into Log File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T08:12:16.483Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-gb/000528934/dsa-2026-480-security-update-for-dell-powerscale-insightiq-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-116436",
"datePublished": "2026-11-13T08:12:16.483Z",
"dateReserved": "2026-10-26T10:04:27.245Z",
"dateUpdated": "2026-11-17T13:10:27.634Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-116431 (GCVE-0-2026-116431)
Vulnerability from nvd – Published: 2026-11-13 09:05 – Updated: 2026-11-13 15:56
VLAI
EPSS
VEX
Summary
Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains a Cleartext Storage of Sensitive Information vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure.
Severity
4.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-13 15:56 UTC
CWE
- CWE-312 - Cleartext Storage of Sensitive Information
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-gb/00052893… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale InsightIQ |
Affected:
0 , < 6.4.1 or later
(semver)
|
Date Public
2026-11-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-116431",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-13T15:56:07.662146Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T15:56:19.297Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-11-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains a Cleartext Storage of Sensitive Information vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"value": "Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains a Cleartext Storage of Sensitive Information vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312: Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T09:05:36.362Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-gb/000528934/dsa-2026-480-security-update-for-dell-powerscale-insightiq-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-116431",
"datePublished": "2026-11-13T09:05:36.362Z",
"dateReserved": "2026-10-26T10:04:27.244Z",
"dateUpdated": "2026-11-13T15:56:19.297Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-116430 (GCVE-0-2026-116430)
Vulnerability from nvd – Published: 2026-11-13 09:02 – Updated: 2026-11-17 17:16
VLAI
EPSS
VEX
Summary
Dell PowerScale InsightIQ, Version 6.4.0, contain an Insufficient Verification of Data Authenticity vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information tampering.
Severity
4.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-17 17:10 UTC
CWE
- CWE-345 - Insufficient Verification of Data Authenticity
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-gb/00052893… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale InsightIQ |
Affected:
0 , < 6.4.1 or later
(semver)
|
Date Public
2026-11-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-116430",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-17T17:10:51.082917Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-17T17:16:24.890Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-11-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale InsightIQ, Version 6.4.0, contain an Insufficient Verification of Data Authenticity vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information tampering."
}
],
"value": "Dell PowerScale InsightIQ, Version 6.4.0, contain an Insufficient Verification of Data Authenticity vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information tampering."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-345",
"description": "CWE-345: Insufficient Verification of Data Authenticity",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T09:02:22.496Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-gb/000528934/dsa-2026-480-security-update-for-dell-powerscale-insightiq-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-116430",
"datePublished": "2026-11-13T09:02:22.496Z",
"dateReserved": "2026-10-26T10:04:27.244Z",
"dateUpdated": "2026-11-17T17:16:24.890Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-116427 (GCVE-0-2026-116427)
Vulnerability from nvd – Published: 2026-11-13 08:15 – Updated: 2026-11-13 16:02
VLAI
EPSS
VEX
Summary
Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains a Missing Authorization vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges.
Severity
5.4 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-13 15:29 UTC
CWE
- CWE-862 - Missing Authorization
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-gb/00052893… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale InsightIQ |
Affected:
0 , < 6.4.1 or later
(semver)
|
Date Public
2026-11-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-116427",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-13T15:29:00.741438Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T16:02:58.381Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-11-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains a Missing Authorization vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"value": "Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains a Missing Authorization vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-862",
"description": "CWE-862: Missing Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T08:15:39.193Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-gb/000528934/dsa-2026-480-security-update-for-dell-powerscale-insightiq-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-116427",
"datePublished": "2026-11-13T08:15:39.193Z",
"dateReserved": "2026-10-26T10:04:27.244Z",
"dateUpdated": "2026-11-13T16:02:58.381Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-116426 (GCVE-0-2026-116426)
Vulnerability from nvd – Published: 2026-11-13 08:36 – Updated: 2026-11-13 16:02
VLAI
EPSS
VEX
Summary
Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information exposure.
Severity
4.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-13 15:29 UTC
CWE
- CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-gb/00052893… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale InsightIQ |
Affected:
0 , < 6.4.1 or later
(semver)
|
Date Public
2026-11-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-116426",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-13T15:29:04.716200Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T16:02:49.020Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-11-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information exposure."
}
],
"value": "Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information exposure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532: Insertion of Sensitive Information into Log File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T08:36:05.678Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-gb/000528934/dsa-2026-480-security-update-for-dell-powerscale-insightiq-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-116426",
"datePublished": "2026-11-13T08:36:05.678Z",
"dateReserved": "2026-10-26T10:04:27.244Z",
"dateUpdated": "2026-11-13T16:02:49.020Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-116425 (GCVE-0-2026-116425)
Vulnerability from nvd – Published: 2026-11-13 09:12 – Updated: 2026-11-13 17:48
VLAI
EPSS
VEX
Summary
Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains unauthorized access vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information tampering and Unauthorized access.
Severity
5.4 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-13 17:47 UTC
CWE
- CWE-862 - CWE : CWE-862
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-gb/00052893… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale InsightIQ |
Affected:
0 , < 6.4.1 or later
(semver)
|
Date Public
2026-11-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-116425",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-13T17:47:50.490929Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T17:48:17.421Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-11-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains unauthorized access vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information tampering and Unauthorized access."
}
],
"value": "Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains unauthorized access vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information tampering and Unauthorized access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-862",
"description": "CWE : CWE-862",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T09:12:08.116Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-gb/000528934/dsa-2026-480-security-update-for-dell-powerscale-insightiq-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-116425",
"datePublished": "2026-11-13T09:12:08.116Z",
"dateReserved": "2026-10-26T10:04:27.243Z",
"dateUpdated": "2026-11-13T17:48:17.421Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-116424 (GCVE-0-2026-116424)
Vulnerability from nvd – Published: 2026-11-13 08:58 – Updated: 2026-11-13 16:02
VLAI
EPSS
VEX
Summary
Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains Unauthorized access vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information tampering and Unauthorized access.
Severity
5.4 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-13 15:29 UTC
CWE
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-gb/00052893… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale InsightIQ |
Affected:
0 , < 6.4.1 or later
(semver)
|
Date Public
2026-11-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-116424",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-13T15:29:07.477284Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T16:02:41.451Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-11-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains Unauthorized access vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information tampering and Unauthorized access."
}
],
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains Unauthorized access vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information tampering and Unauthorized access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-862",
"description": "CWE-862",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T08:58:42.690Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-gb/000528934/dsa-2026-480-security-update-for-dell-powerscale-insightiq-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-116424",
"datePublished": "2026-11-13T08:58:42.690Z",
"dateReserved": "2026-10-26T10:04:27.243Z",
"dateUpdated": "2026-11-13T16:02:41.451Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-116423 (GCVE-0-2026-116423)
Vulnerability from nvd – Published: 2026-11-13 08:39 – Updated: 2026-11-13 15:55
VLAI
EPSS
VEX
Summary
Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains an Improper Verification of Cryptographic Signature vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges and Information tampering.
Severity
5.4 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-13 15:55 UTC
CWE
- CWE-347 - Improper Verification of Cryptographic Signature
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-gb/00052893… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale InsightIQ |
Affected:
0 , < 6.4.1 or later
(semver)
|
Date Public
2026-11-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-116423",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-13T15:55:07.617587Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T15:55:17.658Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-11-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains an Improper Verification of Cryptographic Signature vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges and Information tampering."
}
],
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains an Improper Verification of Cryptographic Signature vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges and Information tampering."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-347",
"description": "CWE-347: Improper Verification of Cryptographic Signature",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T08:39:13.728Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-gb/000528934/dsa-2026-480-security-update-for-dell-powerscale-insightiq-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-116423",
"datePublished": "2026-11-13T08:39:13.728Z",
"dateReserved": "2026-10-26T10:04:27.243Z",
"dateUpdated": "2026-11-13T15:55:17.658Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-116422 (GCVE-0-2026-116422)
Vulnerability from nvd – Published: 2026-11-13 08:48 – Updated: 2026-11-13 15:52
VLAI
EPSS
VEX
Summary
Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure and Information exposure.
Severity
6.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-13 15:52 UTC
CWE
- CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-gb/00052893… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale InsightIQ |
Affected:
0 , < 6.4.1 or later
(semver)
|
Date Public
2026-11-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-116422",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-13T15:52:16.242187Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T15:52:24.895Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-11-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure and Information exposure."
}
],
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure and Information exposure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532: Insertion of Sensitive Information into Log File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T08:48:51.501Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-gb/000528934/dsa-2026-480-security-update-for-dell-powerscale-insightiq-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-116422",
"datePublished": "2026-11-13T08:48:51.501Z",
"dateReserved": "2026-10-26T10:04:27.243Z",
"dateUpdated": "2026-11-13T15:52:24.895Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-116421 (GCVE-0-2026-116421)
Vulnerability from nvd – Published: 2026-11-13 08:29 – Updated: 2026-11-13 17:46
VLAI
EPSS
VEX
Summary
Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure.
Severity
6.4 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-13 17:46 UTC
CWE
- CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-gb/00052893… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale InsightIQ |
Affected:
0 , < 6.4.1 or later
(semver)
|
Date Public
2026-11-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-116421",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-13T17:46:19.221744Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T17:46:30.646Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-11-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"value": "Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532: Insertion of Sensitive Information into Log File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T08:29:36.626Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-gb/000528934/dsa-2026-480-security-update-for-dell-powerscale-insightiq-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-116421",
"datePublished": "2026-11-13T08:29:36.626Z",
"dateReserved": "2026-10-26T10:04:27.243Z",
"dateUpdated": "2026-11-13T17:46:30.646Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-116420 (GCVE-0-2026-116420)
Vulnerability from nvd – Published: 2026-11-13 09:08 – Updated: 2026-11-17 18:06
VLAI
EPSS
VEX
Summary
Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, containsan Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure.
Severity
6.4 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-17 17:41 UTC
CWE
- CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-gb/00052893… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale InsightIQ |
Affected:
0 , < 6.4.1 or later
(semver)
|
Date Public
2026-11-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-116420",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-17T17:41:05.662949Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-17T18:06:18.394Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-11-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, containsan Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, containsan Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532: Insertion of Sensitive Information into Log File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T09:08:33.704Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-gb/000528934/dsa-2026-480-security-update-for-dell-powerscale-insightiq-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-116420",
"datePublished": "2026-11-13T09:08:33.704Z",
"dateReserved": "2026-10-26T10:04:27.243Z",
"dateUpdated": "2026-11-17T18:06:18.394Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-116419 (GCVE-0-2026-116419)
Vulnerability from nvd – Published: 2026-11-13 08:42 – Updated: 2026-11-17 13:12
VLAI
EPSS
VEX
Summary
Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, containsan Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure.
Severity
6.4 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-17 13:11 UTC
CWE
- CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-gb/00052893… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale InsightIQ |
Affected:
0 , < 6.4.1 or later
(semver)
|
Date Public
2026-11-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-116419",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-17T13:11:52.380085Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-17T13:12:10.620Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-11-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, containsan Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, containsan Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532: Insertion of Sensitive Information into Log File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T08:42:10.650Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-gb/000528934/dsa-2026-480-security-update-for-dell-powerscale-insightiq-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-116419",
"datePublished": "2026-11-13T08:42:10.650Z",
"dateReserved": "2026-10-26T10:04:27.243Z",
"dateUpdated": "2026-11-17T13:12:10.620Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-116417 (GCVE-0-2026-116417)
Vulnerability from nvd – Published: 2026-11-13 08:52 – Updated: 2026-11-17 19:27
VLAI
EPSS
VEX
Summary
Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains a Weak Password Requirements vulnerability. An unauthenticated attacker with adjacent network access could potentially exploit this vulnerability, leading to Information disclosure and Unauthorized access.
Severity
8.1 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-17 19:27 UTC
CWE
- CWE-521 - Weak Password Requirements
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-gb/00052893… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale InsightIQ |
Affected:
0 , < 6.4.1 or later
(semver)
|
Date Public
2026-11-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-116417",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-17T19:27:14.142430Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-17T19:27:31.035Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-11-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains a Weak Password Requirements vulnerability. An unauthenticated attacker with adjacent network access could potentially exploit this vulnerability, leading to Information disclosure and Unauthorized access."
}
],
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains a Weak Password Requirements vulnerability. An unauthenticated attacker with adjacent network access could potentially exploit this vulnerability, leading to Information disclosure and Unauthorized access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-521",
"description": "CWE-521: Weak Password Requirements",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T08:52:08.142Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-gb/000528934/dsa-2026-480-security-update-for-dell-powerscale-insightiq-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-116417",
"datePublished": "2026-11-13T08:52:08.142Z",
"dateReserved": "2026-10-26T10:04:27.243Z",
"dateUpdated": "2026-11-17T19:27:31.035Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-116418 (GCVE-0-2026-116418)
Vulnerability from cvelistv5 – Published: 2026-11-13 09:20 – Updated: 2026-11-13 16:02
VLAI
EPSS
VEX
Summary
Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains an Incorrect Authorization vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-13 15:34 UTC
CWE
- CWE-863 - Incorrect Authorization
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-gb/00052893… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale InsightIQ |
Affected:
0 , < 6.4.1 or later
(semver)
|
Date Public
2026-11-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-116418",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-13T15:34:56.742807Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T16:02:31.981Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-11-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains an Incorrect Authorization vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains an Incorrect Authorization vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-863",
"description": "CWE-863: Incorrect Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T09:20:16.351Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-gb/000528934/dsa-2026-480-security-update-for-dell-powerscale-insightiq-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-116418",
"datePublished": "2026-11-13T09:20:16.351Z",
"dateReserved": "2026-10-26T10:04:27.243Z",
"dateUpdated": "2026-11-13T16:02:31.981Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-116433 (GCVE-0-2026-116433)
Vulnerability from cvelistv5 – Published: 2026-11-13 09:16 – Updated: 2026-11-17 13:12
VLAI
EPSS
VEX
Summary
Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains a Missing Authorization vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Unauthorized access.
Severity
4.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-17 13:12 UTC
CWE
- CWE-862 - Missing Authorization
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-gb/00052893… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale InsightIQ |
Affected:
0 , < 6.4.1 or later
(semver)
|
Date Public
2026-11-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-116433",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-17T13:12:30.156022Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-17T13:12:46.010Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-11-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains a Missing Authorization vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Unauthorized access."
}
],
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains a Missing Authorization vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Unauthorized access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-862",
"description": "CWE-862: Missing Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T09:16:36.792Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-gb/000528934/dsa-2026-480-security-update-for-dell-powerscale-insightiq-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-116433",
"datePublished": "2026-11-13T09:16:36.792Z",
"dateReserved": "2026-10-26T10:04:27.244Z",
"dateUpdated": "2026-11-17T13:12:46.010Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-116425 (GCVE-0-2026-116425)
Vulnerability from cvelistv5 – Published: 2026-11-13 09:12 – Updated: 2026-11-13 17:48
VLAI
EPSS
VEX
Summary
Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains unauthorized access vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information tampering and Unauthorized access.
Severity
5.4 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-13 17:47 UTC
CWE
- CWE-862 - CWE : CWE-862
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-gb/00052893… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale InsightIQ |
Affected:
0 , < 6.4.1 or later
(semver)
|
Date Public
2026-11-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-116425",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-13T17:47:50.490929Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T17:48:17.421Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-11-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains unauthorized access vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information tampering and Unauthorized access."
}
],
"value": "Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains unauthorized access vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information tampering and Unauthorized access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-862",
"description": "CWE : CWE-862",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T09:12:08.116Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-gb/000528934/dsa-2026-480-security-update-for-dell-powerscale-insightiq-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-116425",
"datePublished": "2026-11-13T09:12:08.116Z",
"dateReserved": "2026-10-26T10:04:27.243Z",
"dateUpdated": "2026-11-13T17:48:17.421Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-116420 (GCVE-0-2026-116420)
Vulnerability from cvelistv5 – Published: 2026-11-13 09:08 – Updated: 2026-11-17 18:06
VLAI
EPSS
VEX
Summary
Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, containsan Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure.
Severity
6.4 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-17 17:41 UTC
CWE
- CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-gb/00052893… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale InsightIQ |
Affected:
0 , < 6.4.1 or later
(semver)
|
Date Public
2026-11-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-116420",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-17T17:41:05.662949Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-17T18:06:18.394Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-11-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, containsan Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, containsan Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532: Insertion of Sensitive Information into Log File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T09:08:33.704Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-gb/000528934/dsa-2026-480-security-update-for-dell-powerscale-insightiq-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-116420",
"datePublished": "2026-11-13T09:08:33.704Z",
"dateReserved": "2026-10-26T10:04:27.243Z",
"dateUpdated": "2026-11-17T18:06:18.394Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-116431 (GCVE-0-2026-116431)
Vulnerability from cvelistv5 – Published: 2026-11-13 09:05 – Updated: 2026-11-13 15:56
VLAI
EPSS
VEX
Summary
Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains a Cleartext Storage of Sensitive Information vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure.
Severity
4.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-13 15:56 UTC
CWE
- CWE-312 - Cleartext Storage of Sensitive Information
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-gb/00052893… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale InsightIQ |
Affected:
0 , < 6.4.1 or later
(semver)
|
Date Public
2026-11-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-116431",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-13T15:56:07.662146Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T15:56:19.297Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-11-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains a Cleartext Storage of Sensitive Information vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"value": "Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains a Cleartext Storage of Sensitive Information vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312: Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T09:05:36.362Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-gb/000528934/dsa-2026-480-security-update-for-dell-powerscale-insightiq-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-116431",
"datePublished": "2026-11-13T09:05:36.362Z",
"dateReserved": "2026-10-26T10:04:27.244Z",
"dateUpdated": "2026-11-13T15:56:19.297Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-116430 (GCVE-0-2026-116430)
Vulnerability from cvelistv5 – Published: 2026-11-13 09:02 – Updated: 2026-11-17 17:16
VLAI
EPSS
VEX
Summary
Dell PowerScale InsightIQ, Version 6.4.0, contain an Insufficient Verification of Data Authenticity vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information tampering.
Severity
4.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-17 17:10 UTC
CWE
- CWE-345 - Insufficient Verification of Data Authenticity
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-gb/00052893… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale InsightIQ |
Affected:
0 , < 6.4.1 or later
(semver)
|
Date Public
2026-11-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-116430",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-17T17:10:51.082917Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-17T17:16:24.890Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-11-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale InsightIQ, Version 6.4.0, contain an Insufficient Verification of Data Authenticity vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information tampering."
}
],
"value": "Dell PowerScale InsightIQ, Version 6.4.0, contain an Insufficient Verification of Data Authenticity vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information tampering."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-345",
"description": "CWE-345: Insufficient Verification of Data Authenticity",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T09:02:22.496Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-gb/000528934/dsa-2026-480-security-update-for-dell-powerscale-insightiq-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-116430",
"datePublished": "2026-11-13T09:02:22.496Z",
"dateReserved": "2026-10-26T10:04:27.244Z",
"dateUpdated": "2026-11-17T17:16:24.890Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-116424 (GCVE-0-2026-116424)
Vulnerability from cvelistv5 – Published: 2026-11-13 08:58 – Updated: 2026-11-13 16:02
VLAI
EPSS
VEX
Summary
Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains Unauthorized access vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information tampering and Unauthorized access.
Severity
5.4 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-13 15:29 UTC
CWE
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-gb/00052893… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale InsightIQ |
Affected:
0 , < 6.4.1 or later
(semver)
|
Date Public
2026-11-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-116424",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-13T15:29:07.477284Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T16:02:41.451Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-11-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains Unauthorized access vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information tampering and Unauthorized access."
}
],
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains Unauthorized access vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information tampering and Unauthorized access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-862",
"description": "CWE-862",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T08:58:42.690Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-gb/000528934/dsa-2026-480-security-update-for-dell-powerscale-insightiq-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-116424",
"datePublished": "2026-11-13T08:58:42.690Z",
"dateReserved": "2026-10-26T10:04:27.243Z",
"dateUpdated": "2026-11-13T16:02:41.451Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-116417 (GCVE-0-2026-116417)
Vulnerability from cvelistv5 – Published: 2026-11-13 08:52 – Updated: 2026-11-17 19:27
VLAI
EPSS
VEX
Summary
Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains a Weak Password Requirements vulnerability. An unauthenticated attacker with adjacent network access could potentially exploit this vulnerability, leading to Information disclosure and Unauthorized access.
Severity
8.1 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-17 19:27 UTC
CWE
- CWE-521 - Weak Password Requirements
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-gb/00052893… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale InsightIQ |
Affected:
0 , < 6.4.1 or later
(semver)
|
Date Public
2026-11-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-116417",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-17T19:27:14.142430Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-17T19:27:31.035Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-11-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains a Weak Password Requirements vulnerability. An unauthenticated attacker with adjacent network access could potentially exploit this vulnerability, leading to Information disclosure and Unauthorized access."
}
],
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains a Weak Password Requirements vulnerability. An unauthenticated attacker with adjacent network access could potentially exploit this vulnerability, leading to Information disclosure and Unauthorized access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-521",
"description": "CWE-521: Weak Password Requirements",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T08:52:08.142Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-gb/000528934/dsa-2026-480-security-update-for-dell-powerscale-insightiq-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-116417",
"datePublished": "2026-11-13T08:52:08.142Z",
"dateReserved": "2026-10-26T10:04:27.243Z",
"dateUpdated": "2026-11-17T19:27:31.035Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-116422 (GCVE-0-2026-116422)
Vulnerability from cvelistv5 – Published: 2026-11-13 08:48 – Updated: 2026-11-13 15:52
VLAI
EPSS
VEX
Summary
Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure and Information exposure.
Severity
6.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-13 15:52 UTC
CWE
- CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-gb/00052893… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale InsightIQ |
Affected:
0 , < 6.4.1 or later
(semver)
|
Date Public
2026-11-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-116422",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-13T15:52:16.242187Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T15:52:24.895Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-11-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure and Information exposure."
}
],
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure and Information exposure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532: Insertion of Sensitive Information into Log File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T08:48:51.501Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-gb/000528934/dsa-2026-480-security-update-for-dell-powerscale-insightiq-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-116422",
"datePublished": "2026-11-13T08:48:51.501Z",
"dateReserved": "2026-10-26T10:04:27.243Z",
"dateUpdated": "2026-11-13T15:52:24.895Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-116453 (GCVE-0-2026-116453)
Vulnerability from cvelistv5 – Published: 2026-11-13 08:45 – Updated: 2026-11-13 17:47
VLAI
EPSS
VEX
Summary
Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains a Missing Authorization vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information tampering and Unauthorized access.
Severity
5.4 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-13 17:47 UTC
CWE
- CWE-862 - Missing Authorization
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-gb/00052893… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale InsightIQ |
Affected:
0 , < 6.4.1 or later
(semver)
|
Date Public
2026-11-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-116453",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-13T17:47:06.281521Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T17:47:26.001Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-11-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains a Missing Authorization vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information tampering and Unauthorized access."
}
],
"value": "Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains a Missing Authorization vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information tampering and Unauthorized access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-862",
"description": "CWE-862: Missing Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T08:45:39.033Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-gb/000528934/dsa-2026-480-security-update-for-dell-powerscale-insightiq-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-116453",
"datePublished": "2026-11-13T08:45:39.033Z",
"dateReserved": "2026-10-26T10:04:27.247Z",
"dateUpdated": "2026-11-13T17:47:26.001Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-116419 (GCVE-0-2026-116419)
Vulnerability from cvelistv5 – Published: 2026-11-13 08:42 – Updated: 2026-11-17 13:12
VLAI
EPSS
VEX
Summary
Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, containsan Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure.
Severity
6.4 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-17 13:11 UTC
CWE
- CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-gb/00052893… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale InsightIQ |
Affected:
0 , < 6.4.1 or later
(semver)
|
Date Public
2026-11-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-116419",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-17T13:11:52.380085Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-17T13:12:10.620Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-11-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, containsan Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, containsan Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532: Insertion of Sensitive Information into Log File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T08:42:10.650Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-gb/000528934/dsa-2026-480-security-update-for-dell-powerscale-insightiq-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-116419",
"datePublished": "2026-11-13T08:42:10.650Z",
"dateReserved": "2026-10-26T10:04:27.243Z",
"dateUpdated": "2026-11-17T13:12:10.620Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-116423 (GCVE-0-2026-116423)
Vulnerability from cvelistv5 – Published: 2026-11-13 08:39 – Updated: 2026-11-13 15:55
VLAI
EPSS
VEX
Summary
Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains an Improper Verification of Cryptographic Signature vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges and Information tampering.
Severity
5.4 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-13 15:55 UTC
CWE
- CWE-347 - Improper Verification of Cryptographic Signature
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-gb/00052893… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale InsightIQ |
Affected:
0 , < 6.4.1 or later
(semver)
|
Date Public
2026-11-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-116423",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-13T15:55:07.617587Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T15:55:17.658Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-11-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains an Improper Verification of Cryptographic Signature vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges and Information tampering."
}
],
"value": "Dell PowerScale InsightIQ, versions 6.3.0 through 6.4.0, contains an Improper Verification of Cryptographic Signature vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges and Information tampering."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-347",
"description": "CWE-347: Improper Verification of Cryptographic Signature",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T08:39:13.728Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-gb/000528934/dsa-2026-480-security-update-for-dell-powerscale-insightiq-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-116423",
"datePublished": "2026-11-13T08:39:13.728Z",
"dateReserved": "2026-10-26T10:04:27.243Z",
"dateUpdated": "2026-11-13T15:55:17.658Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-116426 (GCVE-0-2026-116426)
Vulnerability from cvelistv5 – Published: 2026-11-13 08:36 – Updated: 2026-11-13 16:02
VLAI
EPSS
VEX
Summary
Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information exposure.
Severity
4.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-13 15:29 UTC
CWE
- CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-gb/00052893… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale InsightIQ |
Affected:
0 , < 6.4.1 or later
(semver)
|
Date Public
2026-11-03 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-116426",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-13T15:29:04.716200Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T16:02:49.020Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-11-03T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information exposure."
}
],
"value": "Dell PowerScale InsightIQ, Versions 6.3.0 through 6.4.0, contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information exposure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532: Insertion of Sensitive Information into Log File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-13T08:36:05.678Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-gb/000528934/dsa-2026-480-security-update-for-dell-powerscale-insightiq-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-116426",
"datePublished": "2026-11-13T08:36:05.678Z",
"dateReserved": "2026-10-26T10:04:27.244Z",
"dateUpdated": "2026-11-13T16:02:49.020Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",