Search
Find a vulnerability
Search criteria
340 vulnerabilities found for JT2Go by Siemens
CVE-2024-41902 (GCVE-0-2024-41902)
Vulnerability from nvd – Published: 2024-10-08 08:40 – Updated: 2024-10-08 18:03
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in JT2Go (All versions < V2406.0003). The affected application contains a stack-based buffer overflow vulnerability that could be triggered while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-08 18:02 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
1 reference
Impacted products
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "jt2go",
"vendor": "siemens",
"versions": [
{
"lessThan": "2406.0003",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-41902",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-08T18:02:30.732549Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-08T18:03:27.584Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0003",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2406.0003). The affected application contains a stack-based buffer overflow vulnerability that could be triggered while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-08T08:40:18.170Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-626178.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-41902",
"datePublished": "2024-10-08T08:40:18.170Z",
"dateReserved": "2024-07-23T10:56:51.267Z",
"dateUpdated": "2024-10-08T18:03:27.584Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-7066 (GCVE-0-2023-7066)
Vulnerability from nvd – Published: 2024-08-12 21:46 – Updated: 2025-08-27 20:42
VLAI
EPSS
VEX
Title
Siemens Teamcenter Visualization and JT2Go Out-of-bounds Read
Summary
The affected applications contain an out of bounds read past the end of
an allocated structure while parsing specially crafted PDF files. This
could allow an attacker to execute code in the context of the current
process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-14 13:56 UTC
CWE
Assigner
References
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < V14.3.0.8
(custom)
|
|
| Siemens | Teamcenter Visualization |
Affected:
0 , < V14.1.0.14
(custom)
Affected: 0 , < V14.2.0.10 (custom) Affected: 0 , < V14.3.0.8 (custom) Affected: 0 , < V2312.0002 (custom) |
|
| siemens | jt2go |
Affected:
0 , < 14.3.0.8
(custom)
cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:* |
|
| siemens | teamcenter_visualization |
Affected:
0 , < 14.1.0.14
(custom)
Affected: 0 , < 14.2.0.10 (custom) Affected: 0 , < 14.3.0.8 (custom) Affected: 0 , < 2312.0002 (custom) cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "jt2go",
"vendor": "siemens",
"versions": [
{
"lessThan": "14.3.0.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "14.1.0.14",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "14.2.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "14.3.0.8",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "2312.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "14.1.0.14",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "14.2.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "14.3.0.8",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "2312.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "14.1.0.14",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "14.2.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "14.3.0.8",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "2312.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "14.1.0.14",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "14.2.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "14.3.0.8",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "2312.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-7066",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-14T13:56:38.749766Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T20:42:53.230Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Teamcenter Visualization",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.1.0.14",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "V14.2.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "V14.3.0.8",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "V2312.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "MoyunSec reported this vulnerability to Siemens."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The affected applications contain an out of bounds read past the end of \nan allocated structure while parsing specially crafted PDF files. This \ncould allow an attacker to execute code in the context of the current \nprocess."
}
],
"value": "The affected applications contain an out of bounds read past the end of \nan allocated structure while parsing specially crafted PDF files. This \ncould allow an attacker to execute code in the context of the current \nprocess."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-12T21:46:38.910Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-722010.html"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-193-03"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003e\nSiemens has released new versions for the affected products and recommends to update to the latest versions.\n\n:\u003c/p\u003e\u003cul\u003e\u003cli\u003eTeamcenter Visualization V14.1: Update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eV14.1.0.14 or later version\u003c/a\u003e\u003c/li\u003e\u003cli\u003eTeamcenter Visualization V14.2: Update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eV14.2.0.10 or later version\u003c/a\u003e\u003c/li\u003e\u003cli\u003eJT2Go: Update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://plm.sw.siemens.com/en-US/plmcomponents/jt/jt2go/\"\u003eV14.3.0.8 or later version\u003c/a\u003e\u003c/li\u003e\u003cli\u003eTeamcenter Visualization V14.3: Update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eV14.3.0.8 or later version\u003c/a\u003e\u003c/li\u003e\u003cli\u003eTeamcenter Visualization V2312: Update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eV2312.0002 or later version\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e\nFor more information see the associated Siemens security advisory SSA-722010\n\n\n\n\u003cbr\u003e"
}
],
"value": "Siemens has released new versions for the affected products and recommends to update to the latest versions.\n\n:\n\n * Teamcenter Visualization V14.1: Update to V14.1.0.14 or later version https://support.sw.siemens.com/ \n * Teamcenter Visualization V14.2: Update to V14.2.0.10 or later version https://support.sw.siemens.com/ \n * JT2Go: Update to V14.3.0.8 or later version https://plm.sw.siemens.com/en-US/plmcomponents/jt/jt2go/ \n * Teamcenter Visualization V14.3: Update to V14.3.0.8 or later version https://support.sw.siemens.com/ \n * Teamcenter Visualization V2312: Update to V2312.0002 or later version https://support.sw.siemens.com/ \n\n\n\nFor more information see the associated Siemens security advisory SSA-722010"
}
],
"source": {
"advisory": "ICSA-24-193-03",
"discovery": "EXTERNAL"
},
"title": "Siemens Teamcenter Visualization and JT2Go Out-of-bounds Read",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eTo reduce risk, Siemens \nrecommends users not open untrusted PDF files in affected applications.\u003cbr\u003e\u003c/p\u003e\u003cul\u003e\n\u003c/ul\u003e\n\u003cp\u003eAs a general security measure, Siemens recommends protecting network \naccess to devices with appropriate mechanisms. To operate the devices in\n a protected IT environment, Siemens recommends configuring the \nenvironment according to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/operational-guidelines-industrial-security\"\u003eSiemens\u0027 operational guidelines for industrial security\u003c/a\u003e and following recommendations in the product manuals.\u003c/p\u003e\n\u003cp\u003eAdditional information on industrial security by Siemens can be found on the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/industrialsecurity\"\u003eSiemens industrial security webpage\u003c/a\u003e\u003c/p\u003eFor more information see the associated Siemens security advisory SSA-722010\n\n\u003cbr\u003e"
}
],
"value": "To reduce risk, Siemens \nrecommends users not open untrusted PDF files in affected applications.\n\n\n\n\n\n\nAs a general security measure, Siemens recommends protecting network \naccess to devices with appropriate mechanisms. To operate the devices in\n a protected IT environment, Siemens recommends configuring the \nenvironment according to Siemens\u0027 operational guidelines for industrial security https://www.siemens.com/cert/operational-guidelines-industrial-security and following recommendations in the product manuals.\n\n\nAdditional information on industrial security by Siemens can be found on the Siemens industrial security webpage https://www.siemens.com/industrialsecurity \n\nFor more information see the associated Siemens security advisory SSA-722010"
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2023-7066",
"datePublished": "2024-08-12T21:46:38.910Z",
"dateReserved": "2023-12-21T19:40:53.933Z",
"dateUpdated": "2025-08-27T20:42:53.230Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-37997 (GCVE-0-2024-37997)
Vulnerability from nvd – Published: 2024-07-09 12:05 – Updated: 2025-08-27 20:42
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in JT Open (All versions < V11.5), JT2Go (All versions < V2406.0003), PLM XML SDK (All versions < V7.1.0.014), Teamcenter Visualization V14.2 (All versions < V14.2.0.13), Teamcenter Visualization V14.3 (All versions < V14.3.0.11), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0003). The affected applications contain a stack based overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-09 13:19 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
9 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT Open |
Affected:
0 , < V11.5
(custom)
|
|
| Siemens | JT2Go |
Affected:
0 , < V2406.0003
(custom)
|
|
| Siemens | PLM XML SDK |
Affected:
0 , < V7.1.0.014
(custom)
|
|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
0 , < V14.2.0.13
(custom)
|
|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.11
(custom)
|
|
| Siemens | Teamcenter Visualization V2312 |
Affected:
0 , < V2312.0008
(custom)
|
|
| Siemens | Teamcenter Visualization V2406 |
Affected:
0 , < V2406.0003
(custom)
|
|
| siemens | jt_open |
Affected:
0 , < V11.5
(custom)
cpe:2.3:a:siemens:jt_open:*:*:*:*:*:*:*:* |
|
| siemens | plm_xml_sdk |
Affected:
V7.1.0.014
cpe:2.3:a:siemens:plm_xml_sdk:v7.1.0.0014:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:jt_open:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "jt_open",
"vendor": "siemens",
"versions": [
{
"lessThan": "V11.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:plm_xml_sdk:v7.1.0.0014:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "plm_xml_sdk",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "V7.1.0.014"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-37997",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T13:19:33.793225Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T20:42:54.635Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T04:04:24.591Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-824889.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT Open",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0003",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PLM XML SDK",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.1.0.014",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0008",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0003",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT Open (All versions \u003c V11.5), JT2Go (All versions \u003c V2406.0003), PLM XML SDK (All versions \u003c V7.1.0.014), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.13), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.11), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Teamcenter Visualization V2406 (All versions \u003c V2406.0003). The affected applications contain a stack based overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-08T08:40:15.076Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-824889.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-959281.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-37997",
"datePublished": "2024-07-09T12:05:06.114Z",
"dateReserved": "2024-06-11T08:32:52.184Z",
"dateUpdated": "2025-08-27T20:42:54.635Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-37996 (GCVE-0-2024-37996)
Vulnerability from nvd – Published: 2024-07-09 12:05 – Updated: 2025-08-27 20:42
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in JT Open (All versions < V11.5), JT2Go (All versions < V2406.0003), PLM XML SDK (All versions < V7.1.0.014), Teamcenter Visualization V14.2 (All versions < V14.2.0.13), Teamcenter Visualization V14.3 (All versions < V14.3.0.11), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0003). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted XML files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-15 18:31 UTC
CWE
- CWE-476 - NULL Pointer Dereference
Assigner
References
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT Open |
Affected:
0 , < V11.5
(custom)
|
|
| Siemens | JT2Go |
Affected:
0 , < V2406.0003
(custom)
|
|
| Siemens | PLM XML SDK |
Affected:
0 , < V7.1.0.014
(custom)
|
|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
0 , < V14.2.0.13
(custom)
|
|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.11
(custom)
|
|
| Siemens | Teamcenter Visualization V2312 |
Affected:
0 , < V2312.0008
(custom)
|
|
| Siemens | Teamcenter Visualization V2406 |
Affected:
0 , < V2406.0003
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-37996",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-15T18:31:15.685735Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T20:42:54.503Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T04:04:24.762Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-824889.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT Open",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0003",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PLM XML SDK",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.1.0.014",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0008",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0003",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT Open (All versions \u003c V11.5), JT2Go (All versions \u003c V2406.0003), PLM XML SDK (All versions \u003c V7.1.0.014), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.13), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.11), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Teamcenter Visualization V2406 (All versions \u003c V2406.0003). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted XML files. An attacker could leverage this vulnerability to crash the application causing denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476: NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-08T08:40:13.781Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-824889.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-959281.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-37996",
"datePublished": "2024-07-09T12:05:04.781Z",
"dateReserved": "2024-06-11T08:32:52.184Z",
"dateUpdated": "2025-08-27T20:42:54.503Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-34086 (GCVE-0-2024-34086)
Vulnerability from nvd – Published: 2024-05-14 10:03 – Updated: 2024-08-02 02:42
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0001), Teamcenter Visualization V14.1 (All versions < V14.1.0.13), Teamcenter Visualization V14.2 (All versions < V14.2.0.10), Teamcenter Visualization V14.3 (All versions < V14.3.0.7), Teamcenter Visualization V2312 (All versions < V2312.0001). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted CGM file.
This could allow an attacker to execute code in the context of the current process.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-14 15:19 UTC
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
1 reference
Impacted products
10 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < V2312.0001
(custom)
|
|
| Siemens | Teamcenter Visualization V14.1 |
Affected:
0 , < V14.1.0.13
(custom)
|
|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
0 , < V14.2.0.10
(custom)
|
|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.7
(custom)
|
|
| Siemens | Teamcenter Visualization V2312 |
Affected:
0 , < V2312.0001
(custom)
|
|
| siemens | jt2go |
Affected:
0 , < V2312.0001
(custom)
cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:* |
|
| siemens | teamcenter_visualization |
Affected:
0 , < V14.1.0.13
(custom)
cpe:2.3:a:siemens:teamcenter_visualization:14.1:*:*:*:*:*:*:* |
|
| siemens | teamcenter_visualization |
Affected:
0 , < 14.2.0.10
(custom)
cpe:2.3:a:siemens:teamcenter_visualization:14.2:*:*:*:*:*:*:* |
|
| siemens | teamcenter_visualization |
Affected:
0 , < V2312.0001
(custom)
cpe:2.3:a:siemens:teamcenter_visualization:2312:*:*:*:*:*:*:* |
|
| siemens | teamcenter_visualization |
Affected:
0 , < 14.3.0.7
(custom)
cpe:2.3:a:siemens:teamcenter_visualization:14.3:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "jt2go",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2312.0001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:14.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "V14.1.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:14.2:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "14.2.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:2312:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2312.0001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:14.3:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "14.3.0.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-34086",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T15:19:05.198442Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T18:22:25.821Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:42:59.863Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-661579.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.1.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0001), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.13), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.10), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.7), Teamcenter Visualization V2312 (All versions \u003c V2312.0001). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted CGM file.\r\nThis could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-15T07:24:55.854Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-661579.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-34086",
"datePublished": "2024-05-14T10:03:10.774Z",
"dateReserved": "2024-04-30T09:05:07.900Z",
"dateUpdated": "2024-08-02T02:42:59.863Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-34085 (GCVE-0-2024-34085)
Vulnerability from nvd – Published: 2024-05-14 10:03 – Updated: 2024-08-02 02:42
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0001), Teamcenter Visualization V14.1 (All versions < V14.1.0.13), Teamcenter Visualization V14.2 (All versions < V14.2.0.10), Teamcenter Visualization V14.3 (All versions < V14.3.0.7), Teamcenter Visualization V2312 (All versions < V2312.0001). The affected applications contain a stack overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-14 14:07 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
1 reference
Impacted products
9 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < V2312.0001
(custom)
|
|
| Siemens | Teamcenter Visualization V14.1 |
Affected:
0 , < V14.1.0.13
(custom)
|
|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
0 , < V14.2.0.10
(custom)
|
|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.7
(custom)
|
|
| Siemens | Teamcenter Visualization V2312 |
Affected:
0 , < V2312.0001
(custom)
|
|
| siemens | teamcenter_visualization |
Affected:
14.1 , < 14.1.0.13
(custom)
cpe:2.3:a:siemens:teamcenter_visualization:14.1:*:*:*:*:*:*:* |
|
| siemens | teamcenter_visualization |
Affected:
14.2 , < 14.2.0.10
(custom)
cpe:2.3:a:siemens:teamcenter_visualization:14.2:*:*:*:*:*:*:* |
|
| siemens | jt2go |
Affected:
0 , < 2312.0001
(custom)
cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:* |
|
| siemens | teamcenter_visualization |
Affected:
2312 , < 2312.0001
(custom)
cpe:2.3:a:siemens:teamcenter_visualization:2312:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:14.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "14.1.0.13",
"status": "affected",
"version": "14.1",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:14.2:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "14.2.0.10",
"status": "affected",
"version": "14.2",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "jt2go",
"vendor": "siemens",
"versions": [
{
"lessThan": "2312.0001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:2312:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "2312.0001",
"status": "affected",
"version": "2312",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-34085",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T14:07:42.511828Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T18:03:43.492Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:42:59.891Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-661579.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.1.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0001), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.13), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.10), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.7), Teamcenter Visualization V2312 (All versions \u003c V2312.0001). The affected applications contain a stack overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-15T07:24:54.668Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-661579.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-34085",
"datePublished": "2024-05-14T10:03:09.574Z",
"dateReserved": "2024-04-30T09:05:07.900Z",
"dateUpdated": "2024-08-02T02:42:59.891Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-32637 (GCVE-0-2024-32637)
Vulnerability from nvd – Published: 2024-05-14 10:02 – Updated: 2024-08-13 07:54
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0005), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.10), Teamcenter Visualization V2312 (All versions < V2312.0005). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-14 13:37 UTC
CWE
- CWE-476 - NULL Pointer Dereference
Assigner
References
Impacted products
5 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < V2312.0005
(custom)
|
|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
0 , < V14.2.0.12
(custom)
|
|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.10
(custom)
|
|
| Siemens | Teamcenter Visualization V2312 |
Affected:
0 , < V2312.0005
(custom)
|
|
| siemens | ps_iges_parasolid_translator_component |
Affected:
0 , < v27.1.215
(custom)
cpe:2.3:a:siemens:ps_iges_parasolid_translator_component:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:ps_iges_parasolid_translator_component:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ps_iges_parasolid_translator_component",
"vendor": "siemens",
"versions": [
{
"lessThan": "v27.1.215 ",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-32637",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T13:37:33.414539Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-18T18:07:35.849Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:13:40.086Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0005), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.10), Teamcenter Visualization V2312 (All versions \u003c V2312.0005). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476: NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-13T07:54:07.678Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-856475.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-32637",
"datePublished": "2024-05-14T10:02:44.682Z",
"dateReserved": "2024-04-16T10:52:15.707Z",
"dateUpdated": "2024-08-13T07:54:07.678Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-32636 (GCVE-0-2024-32636)
Vulnerability from nvd – Published: 2024-05-14 10:02 – Updated: 2024-08-13 07:54
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0005), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.10), Teamcenter Visualization V2312 (All versions < V2312.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-14 13:37 UTC
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < V2312.0005
(custom)
|
|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
0 , < V14.2.0.12
(custom)
|
|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.10
(custom)
|
|
| Siemens | Teamcenter Visualization V2312 |
Affected:
0 , < V2312.0005
(custom)
|
|
| siemens | parasolid |
Affected:
35.1 , < 35.1.256
(custom)
cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:* |
|
| siemens | parasolid |
Affected:
36.0 , < 36.0.208
(custom)
cpe:2.3:a:siemens:parasolid:36.0:*:*:*:*:*:*:* |
|
| siemens | parasolid |
Affected:
36.1 , < 36.1.173
(custom)
cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "35.1.256",
"status": "affected",
"version": "35.1",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.0.208",
"status": "affected",
"version": "36.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.1.173",
"status": "affected",
"version": "36.1",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-32636",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T13:37:41.622204Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:29:19.950Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:13:40.376Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0005), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.10), Teamcenter Visualization V2312 (All versions \u003c V2312.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-13T07:54:06.352Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-856475.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-32636",
"datePublished": "2024-05-14T10:02:43.480Z",
"dateReserved": "2024-04-16T10:52:15.707Z",
"dateUpdated": "2024-08-13T07:54:06.352Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-32635 (GCVE-0-2024-32635)
Vulnerability from nvd – Published: 2024-05-14 10:02 – Updated: 2024-08-13 07:54
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0005), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.10), Teamcenter Visualization V2312 (All versions < V2312.0005). The affected applications contain an out of bounds read past the unmapped memory region while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-14 13:37 UTC
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < V2312.0005
(custom)
|
|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
0 , < V14.2.0.12
(custom)
|
|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.10
(custom)
|
|
| Siemens | Teamcenter Visualization V2312 |
Affected:
0 , < V2312.0005
(custom)
|
|
| siemens | parasolid |
Affected:
35.1 , < 35.1.256
(custom)
cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:* |
|
| siemens | parasolid |
Affected:
36.0 , < 36.0.208
(custom)
cpe:2.3:a:siemens:parasolid:36.0:*:*:*:*:*:*:* |
|
| siemens | parasolid |
Affected:
36.1 , < 36.1.173
(custom)
cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "35.1.256",
"status": "affected",
"version": "35.1",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.0.208",
"status": "affected",
"version": "36.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.1.173",
"status": "affected",
"version": "36.1",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-32635",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T13:37:49.970409Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:27:51.096Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:13:40.417Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0005), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.10), Teamcenter Visualization V2312 (All versions \u003c V2312.0005). The affected applications contain an out of bounds read past the unmapped memory region while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-13T07:54:05.071Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-856475.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-32635",
"datePublished": "2024-05-14T10:02:42.291Z",
"dateReserved": "2024-04-16T10:52:15.707Z",
"dateUpdated": "2024-08-13T07:54:05.071Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-26277 (GCVE-0-2024-26277)
Vulnerability from nvd – Published: 2024-04-09 08:34 – Updated: 2024-08-13 07:54
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0004), Parasolid V35.1 (All versions < V35.1.254), Parasolid V36.0 (All versions < V36.0.207), Parasolid V36.1 (All versions < V36.1.147), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-04-09 19:51 UTC
CWE
- CWE-476 - NULL Pointer Dereference
Assigner
References
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < V2312.0004
(custom)
|
|
| Siemens | Parasolid V35.1 |
Affected:
0 , < V35.1.254
(custom)
|
|
| Siemens | Parasolid V36.0 |
Affected:
0 , < V36.0.207
(custom)
|
|
| Siemens | Parasolid V36.1 |
Affected:
0 , < V36.1.147
(custom)
|
|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
0 , < V14.2.0.12
(custom)
|
|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.9
(custom)
|
|
| Siemens | Teamcenter Visualization V2312 |
Affected:
0 , < V2312.0004
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-26277",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-09T19:51:56.120704Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:49:18.998Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T00:07:18.954Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V35.1.254",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.0.207",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.1.147",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0004), Parasolid V35.1 (All versions \u003c V35.1.254), Parasolid V36.0 (All versions \u003c V36.0.207), Parasolid V36.1 (All versions \u003c V36.1.147), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.9), Teamcenter Visualization V2312 (All versions \u003c V2312.0004). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476: NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-13T07:54:03.735Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-26277",
"datePublished": "2024-04-09T08:34:38.896Z",
"dateReserved": "2024-02-15T10:54:03.168Z",
"dateUpdated": "2024-08-13T07:54:03.735Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-26276 (GCVE-0-2024-26276)
Vulnerability from nvd – Published: 2024-04-09 08:34 – Updated: 2024-08-13 07:54
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0004), Parasolid V35.1 (All versions < V35.1.254), Parasolid V36.0 (All versions < V36.0.207), Parasolid V36.1 (All versions < V36.1.147), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected application contains a stack exhaustion vulnerability while parsing a specially crafted X_T file. This could allow an attacker to cause denial of service condition.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-14 13:40 UTC
CWE
- CWE-770 - Allocation of Resources Without Limits or Throttling
Assigner
References
Impacted products
10 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < V2312.0004
(custom)
|
|
| Siemens | Parasolid V35.1 |
Affected:
0 , < V35.1.254
(custom)
|
|
| Siemens | Parasolid V36.0 |
Affected:
0 , < V36.0.207
(custom)
|
|
| Siemens | Parasolid V36.1 |
Affected:
0 , < V36.1.147
(custom)
|
|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
0 , < V14.2.0.12
(custom)
|
|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.9
(custom)
|
|
| Siemens | Teamcenter Visualization V2312 |
Affected:
0 , < V2312.0004
(custom)
|
|
| siemens | parasolid |
Affected:
35.1 , < 35.1.254
(custom)
cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:* |
|
| siemens | parasolid |
Affected:
36.0 , < 36.0.207
(custom)
cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:* |
|
| siemens | parasolid |
Affected:
36.1 , < 36.1.147
(custom)
cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "35.1.254",
"status": "affected",
"version": "35.1",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.0.207",
"status": "affected",
"version": "36.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.1.147",
"status": "affected",
"version": "36.1",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-26276",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T13:40:25.505191Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T14:53:58.636Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T00:07:18.871Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V35.1.254",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.0.207",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.1.147",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0004), Parasolid V35.1 (All versions \u003c V35.1.254), Parasolid V36.0 (All versions \u003c V36.0.207), Parasolid V36.1 (All versions \u003c V36.1.147), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.9), Teamcenter Visualization V2312 (All versions \u003c V2312.0004). The affected application contains a stack exhaustion vulnerability while parsing a specially crafted X_T file. This could allow an attacker to cause denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-770",
"description": "CWE-770: Allocation of Resources Without Limits or Throttling",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-13T07:54:02.376Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-26276",
"datePublished": "2024-04-09T08:34:37.744Z",
"dateReserved": "2024-02-15T10:54:03.168Z",
"dateUpdated": "2024-08-13T07:54:02.376Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-26275 (GCVE-0-2024-26275)
Vulnerability from nvd – Published: 2024-04-09 08:34 – Updated: 2024-08-13 07:54
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0004), Parasolid V35.1 (All versions < V35.1.254), Parasolid V36.0 (All versions < V36.0.207), Parasolid V36.1 (All versions < V36.1.147), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-04-09 15:24 UTC
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
10 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < V2312.0004
(custom)
|
|
| Siemens | Parasolid V35.1 |
Affected:
0 , < V35.1.254
(custom)
|
|
| Siemens | Parasolid V36.0 |
Affected:
0 , < V36.0.207
(custom)
|
|
| Siemens | Parasolid V36.1 |
Affected:
0 , < V36.1.147
(custom)
|
|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
0 , < V14.2.0.12
(custom)
|
|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.9
(custom)
|
|
| Siemens | Teamcenter Visualization V2312 |
Affected:
0 , < V2312.0004
(custom)
|
|
| siemens | jt2go |
Affected:
0 , < 2312.0004
(custom)
cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:* |
|
| siemens | parasolid |
Affected:
0 , < 35.1.254
(custom)
Affected: 0 , < 36.0.207 (custom) Affected: 0 , < 36.1.147 (custom) cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:* |
|
| siemens | teamcenter_visualization |
Affected:
14.2 , < *
(custom)
Affected: 14.3 , < 14.3.0.9 (custom) Affected: 2312 , < 2312.0004 (custom) cpe:2.3:a:siemens:teamcenter_visualization:14.2:*:*:*:*:*:*:* cpe:2.3:a:siemens:teamcenter_visualization:14.3:*:*:*:*:*:*:* cpe:2.3:a:siemens:teamcenter_visualization:2312:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "jt2go",
"vendor": "siemens",
"versions": [
{
"lessThan": "2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "35.1.254",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "36.0.207",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "36.1.147",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:14.2:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:teamcenter_visualization:14.3:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:teamcenter_visualization:2312:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "14.2",
"versionType": "custom"
},
{
"lessThan": "14.3.0.9",
"status": "affected",
"version": "14.3",
"versionType": "custom"
},
{
"lessThan": "2312.0004",
"status": "affected",
"version": "2312",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-26275",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-09T15:24:40.222186Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-31T18:33:02.344Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T00:07:19.343Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V35.1.254",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.0.207",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.1.147",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0004), Parasolid V35.1 (All versions \u003c V35.1.254), Parasolid V36.0 (All versions \u003c V36.0.207), Parasolid V36.1 (All versions \u003c V36.1.147), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.9), Teamcenter Visualization V2312 (All versions \u003c V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-13T07:54:00.911Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-26275",
"datePublished": "2024-04-09T08:34:36.604Z",
"dateReserved": "2024-02-15T10:54:03.168Z",
"dateUpdated": "2024-08-13T07:54:00.911Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-51746 (GCVE-0-2023-51746)
Vulnerability from nvd – Published: 2024-01-09 10:00 – Updated: 2024-09-04 15:14
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.6), Teamcenter Visualization V13.3 (All versions < V13.3.0.13), Teamcenter Visualization V14.1 (All versions < V14.1.0.12), Teamcenter Visualization V14.2 (All versions < V14.2.0.9), Teamcenter Visualization V14.3 (All versions < V14.3.0.6). The affected applications contain a stack overflow vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-04 15:13 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
1 reference
Impacted products
5 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V14.3.0.6
|
|
| Siemens | Teamcenter Visualization V13.3 |
Affected:
All versions < V13.3.0.13
|
|
| Siemens | Teamcenter Visualization V14.1 |
Affected:
All versions < V14.1.0.12
|
|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
All versions < V14.2.0.9
|
|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
All versions < V14.3.0.6
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T22:48:11.101Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-794653.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-51746",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-04T15:13:57.367529Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-04T15:14:05.889Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.13"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.9"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.6), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.13), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.12), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.9), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.6). The affected applications contain a stack overflow vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-09T10:00:18.333Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-794653.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-51746",
"datePublished": "2024-01-09T10:00:18.333Z",
"dateReserved": "2023-12-22T11:30:22.672Z",
"dateUpdated": "2024-09-04T15:14:05.889Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-51745 (GCVE-0-2023-51745)
Vulnerability from nvd – Published: 2024-01-09 10:00 – Updated: 2025-06-03 14:31
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.6), Teamcenter Visualization V13.3 (All versions < V13.3.0.13), Teamcenter Visualization V14.1 (All versions < V14.1.0.12), Teamcenter Visualization V14.2 (All versions < V14.2.0.9), Teamcenter Visualization V14.3 (All versions < V14.3.0.6). The affected applications contain a stack overflow vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-05-08 18:45 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
1 reference
Impacted products
5 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V14.3.0.6
|
|
| Siemens | Teamcenter Visualization V13.3 |
Affected:
All versions < V13.3.0.13
|
|
| Siemens | Teamcenter Visualization V14.1 |
Affected:
All versions < V14.1.0.12
|
|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
All versions < V14.2.0.9
|
|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
All versions < V14.3.0.6
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T22:40:34.255Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-794653.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-51745",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-08T18:45:55.954048Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-03T14:31:19.908Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.13"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.9"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.6), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.13), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.12), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.9), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.6). The affected applications contain a stack overflow vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-09T10:00:17.032Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-794653.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-51745",
"datePublished": "2024-01-09T10:00:17.032Z",
"dateReserved": "2023-12-22T11:30:22.671Z",
"dateUpdated": "2025-06-03T14:31:19.908Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-51744 (GCVE-0-2023-51744)
Vulnerability from nvd – Published: 2024-01-09 10:00 – Updated: 2025-06-09 20:32
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.6), Teamcenter Visualization V13.3 (All versions < V13.3.0.13), Teamcenter Visualization V14.1 (All versions < V14.1.0.12), Teamcenter Visualization V14.2 (All versions < V14.2.0.9), Teamcenter Visualization V14.3 (All versions < V14.3.0.6). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-06-09 20:30 UTC
CWE
- CWE-476 - NULL Pointer Dereference
Assigner
References
1 reference
Impacted products
5 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V14.3.0.6
|
|
| Siemens | Teamcenter Visualization V13.3 |
Affected:
All versions < V13.3.0.13
|
|
| Siemens | Teamcenter Visualization V14.1 |
Affected:
All versions < V14.1.0.12
|
|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
All versions < V14.2.0.9
|
|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
All versions < V14.3.0.6
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T22:40:34.169Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-794653.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-51744",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-09T20:30:16.453695Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-09T20:32:57.525Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.13"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.9"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.6), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.13), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.12), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.9), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.6). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476: NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-09T10:00:15.708Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-794653.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-51744",
"datePublished": "2024-01-09T10:00:15.708Z",
"dateReserved": "2023-12-22T11:30:22.671Z",
"dateUpdated": "2025-06-09T20:32:57.525Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-51439 (GCVE-0-2023-51439)
Vulnerability from nvd – Published: 2024-01-09 10:00 – Updated: 2025-04-17 17:54
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.6), Teamcenter Visualization V13.3 (All versions < V13.3.0.13), Teamcenter Visualization V14.1 (All versions < V14.1.0.12), Teamcenter Visualization V14.2 (All versions < V14.2.0.9), Teamcenter Visualization V14.3 (All versions < V14.3.0.6). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-01-10 18:29 UTC
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
1 reference
Impacted products
5 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V14.3.0.6
|
|
| Siemens | Teamcenter Visualization V13.3 |
Affected:
All versions < V13.3.0.13
|
|
| Siemens | Teamcenter Visualization V14.1 |
Affected:
All versions < V14.1.0.12
|
|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
All versions < V14.2.0.9
|
|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
All versions < V14.3.0.6
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T22:32:10.018Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-794653.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-51439",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-01-10T18:29:28.656739Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-17T17:54:26.450Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.13"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.9"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.6), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.13), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.12), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.9), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.6). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-09T10:00:14.394Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-794653.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-51439",
"datePublished": "2024-01-09T10:00:14.394Z",
"dateReserved": "2023-12-19T11:47:14.991Z",
"dateUpdated": "2025-04-17T17:54:26.450Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-41902 (GCVE-0-2024-41902)
Vulnerability from cvelistv5 – Published: 2024-10-08 08:40 – Updated: 2024-10-08 18:03
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in JT2Go (All versions < V2406.0003). The affected application contains a stack-based buffer overflow vulnerability that could be triggered while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-08 18:02 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
1 reference
Impacted products
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "jt2go",
"vendor": "siemens",
"versions": [
{
"lessThan": "2406.0003",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-41902",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-08T18:02:30.732549Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-08T18:03:27.584Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0003",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2406.0003). The affected application contains a stack-based buffer overflow vulnerability that could be triggered while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-08T08:40:18.170Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-626178.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-41902",
"datePublished": "2024-10-08T08:40:18.170Z",
"dateReserved": "2024-07-23T10:56:51.267Z",
"dateUpdated": "2024-10-08T18:03:27.584Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-7066 (GCVE-0-2023-7066)
Vulnerability from cvelistv5 – Published: 2024-08-12 21:46 – Updated: 2025-08-27 20:42
VLAI
EPSS
VEX
Title
Siemens Teamcenter Visualization and JT2Go Out-of-bounds Read
Summary
The affected applications contain an out of bounds read past the end of
an allocated structure while parsing specially crafted PDF files. This
could allow an attacker to execute code in the context of the current
process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-14 13:56 UTC
CWE
Assigner
References
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < V14.3.0.8
(custom)
|
|
| Siemens | Teamcenter Visualization |
Affected:
0 , < V14.1.0.14
(custom)
Affected: 0 , < V14.2.0.10 (custom) Affected: 0 , < V14.3.0.8 (custom) Affected: 0 , < V2312.0002 (custom) |
|
| siemens | jt2go |
Affected:
0 , < 14.3.0.8
(custom)
cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:* |
|
| siemens | teamcenter_visualization |
Affected:
0 , < 14.1.0.14
(custom)
Affected: 0 , < 14.2.0.10 (custom) Affected: 0 , < 14.3.0.8 (custom) Affected: 0 , < 2312.0002 (custom) cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "jt2go",
"vendor": "siemens",
"versions": [
{
"lessThan": "14.3.0.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "14.1.0.14",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "14.2.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "14.3.0.8",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "2312.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "14.1.0.14",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "14.2.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "14.3.0.8",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "2312.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "14.1.0.14",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "14.2.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "14.3.0.8",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "2312.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "14.1.0.14",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "14.2.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "14.3.0.8",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "2312.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-7066",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-14T13:56:38.749766Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T20:42:53.230Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Teamcenter Visualization",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.1.0.14",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "V14.2.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "V14.3.0.8",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "V2312.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "MoyunSec reported this vulnerability to Siemens."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The affected applications contain an out of bounds read past the end of \nan allocated structure while parsing specially crafted PDF files. This \ncould allow an attacker to execute code in the context of the current \nprocess."
}
],
"value": "The affected applications contain an out of bounds read past the end of \nan allocated structure while parsing specially crafted PDF files. This \ncould allow an attacker to execute code in the context of the current \nprocess."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-12T21:46:38.910Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-722010.html"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-193-03"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003e\nSiemens has released new versions for the affected products and recommends to update to the latest versions.\n\n:\u003c/p\u003e\u003cul\u003e\u003cli\u003eTeamcenter Visualization V14.1: Update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eV14.1.0.14 or later version\u003c/a\u003e\u003c/li\u003e\u003cli\u003eTeamcenter Visualization V14.2: Update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eV14.2.0.10 or later version\u003c/a\u003e\u003c/li\u003e\u003cli\u003eJT2Go: Update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://plm.sw.siemens.com/en-US/plmcomponents/jt/jt2go/\"\u003eV14.3.0.8 or later version\u003c/a\u003e\u003c/li\u003e\u003cli\u003eTeamcenter Visualization V14.3: Update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eV14.3.0.8 or later version\u003c/a\u003e\u003c/li\u003e\u003cli\u003eTeamcenter Visualization V2312: Update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eV2312.0002 or later version\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e\nFor more information see the associated Siemens security advisory SSA-722010\n\n\n\n\u003cbr\u003e"
}
],
"value": "Siemens has released new versions for the affected products and recommends to update to the latest versions.\n\n:\n\n * Teamcenter Visualization V14.1: Update to V14.1.0.14 or later version https://support.sw.siemens.com/ \n * Teamcenter Visualization V14.2: Update to V14.2.0.10 or later version https://support.sw.siemens.com/ \n * JT2Go: Update to V14.3.0.8 or later version https://plm.sw.siemens.com/en-US/plmcomponents/jt/jt2go/ \n * Teamcenter Visualization V14.3: Update to V14.3.0.8 or later version https://support.sw.siemens.com/ \n * Teamcenter Visualization V2312: Update to V2312.0002 or later version https://support.sw.siemens.com/ \n\n\n\nFor more information see the associated Siemens security advisory SSA-722010"
}
],
"source": {
"advisory": "ICSA-24-193-03",
"discovery": "EXTERNAL"
},
"title": "Siemens Teamcenter Visualization and JT2Go Out-of-bounds Read",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eTo reduce risk, Siemens \nrecommends users not open untrusted PDF files in affected applications.\u003cbr\u003e\u003c/p\u003e\u003cul\u003e\n\u003c/ul\u003e\n\u003cp\u003eAs a general security measure, Siemens recommends protecting network \naccess to devices with appropriate mechanisms. To operate the devices in\n a protected IT environment, Siemens recommends configuring the \nenvironment according to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/operational-guidelines-industrial-security\"\u003eSiemens\u0027 operational guidelines for industrial security\u003c/a\u003e and following recommendations in the product manuals.\u003c/p\u003e\n\u003cp\u003eAdditional information on industrial security by Siemens can be found on the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/industrialsecurity\"\u003eSiemens industrial security webpage\u003c/a\u003e\u003c/p\u003eFor more information see the associated Siemens security advisory SSA-722010\n\n\u003cbr\u003e"
}
],
"value": "To reduce risk, Siemens \nrecommends users not open untrusted PDF files in affected applications.\n\n\n\n\n\n\nAs a general security measure, Siemens recommends protecting network \naccess to devices with appropriate mechanisms. To operate the devices in\n a protected IT environment, Siemens recommends configuring the \nenvironment according to Siemens\u0027 operational guidelines for industrial security https://www.siemens.com/cert/operational-guidelines-industrial-security and following recommendations in the product manuals.\n\n\nAdditional information on industrial security by Siemens can be found on the Siemens industrial security webpage https://www.siemens.com/industrialsecurity \n\nFor more information see the associated Siemens security advisory SSA-722010"
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2023-7066",
"datePublished": "2024-08-12T21:46:38.910Z",
"dateReserved": "2023-12-21T19:40:53.933Z",
"dateUpdated": "2025-08-27T20:42:53.230Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-37997 (GCVE-0-2024-37997)
Vulnerability from cvelistv5 – Published: 2024-07-09 12:05 – Updated: 2025-08-27 20:42
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in JT Open (All versions < V11.5), JT2Go (All versions < V2406.0003), PLM XML SDK (All versions < V7.1.0.014), Teamcenter Visualization V14.2 (All versions < V14.2.0.13), Teamcenter Visualization V14.3 (All versions < V14.3.0.11), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0003). The affected applications contain a stack based overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-09 13:19 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
9 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT Open |
Affected:
0 , < V11.5
(custom)
|
|
| Siemens | JT2Go |
Affected:
0 , < V2406.0003
(custom)
|
|
| Siemens | PLM XML SDK |
Affected:
0 , < V7.1.0.014
(custom)
|
|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
0 , < V14.2.0.13
(custom)
|
|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.11
(custom)
|
|
| Siemens | Teamcenter Visualization V2312 |
Affected:
0 , < V2312.0008
(custom)
|
|
| Siemens | Teamcenter Visualization V2406 |
Affected:
0 , < V2406.0003
(custom)
|
|
| siemens | jt_open |
Affected:
0 , < V11.5
(custom)
cpe:2.3:a:siemens:jt_open:*:*:*:*:*:*:*:* |
|
| siemens | plm_xml_sdk |
Affected:
V7.1.0.014
cpe:2.3:a:siemens:plm_xml_sdk:v7.1.0.0014:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:jt_open:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "jt_open",
"vendor": "siemens",
"versions": [
{
"lessThan": "V11.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:plm_xml_sdk:v7.1.0.0014:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "plm_xml_sdk",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "V7.1.0.014"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-37997",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T13:19:33.793225Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T20:42:54.635Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T04:04:24.591Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-824889.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT Open",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0003",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PLM XML SDK",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.1.0.014",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0008",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0003",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT Open (All versions \u003c V11.5), JT2Go (All versions \u003c V2406.0003), PLM XML SDK (All versions \u003c V7.1.0.014), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.13), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.11), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Teamcenter Visualization V2406 (All versions \u003c V2406.0003). The affected applications contain a stack based overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-08T08:40:15.076Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-824889.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-959281.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-37997",
"datePublished": "2024-07-09T12:05:06.114Z",
"dateReserved": "2024-06-11T08:32:52.184Z",
"dateUpdated": "2025-08-27T20:42:54.635Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-37996 (GCVE-0-2024-37996)
Vulnerability from cvelistv5 – Published: 2024-07-09 12:05 – Updated: 2025-08-27 20:42
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in JT Open (All versions < V11.5), JT2Go (All versions < V2406.0003), PLM XML SDK (All versions < V7.1.0.014), Teamcenter Visualization V14.2 (All versions < V14.2.0.13), Teamcenter Visualization V14.3 (All versions < V14.3.0.11), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0003). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted XML files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-15 18:31 UTC
CWE
- CWE-476 - NULL Pointer Dereference
Assigner
References
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT Open |
Affected:
0 , < V11.5
(custom)
|
|
| Siemens | JT2Go |
Affected:
0 , < V2406.0003
(custom)
|
|
| Siemens | PLM XML SDK |
Affected:
0 , < V7.1.0.014
(custom)
|
|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
0 , < V14.2.0.13
(custom)
|
|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.11
(custom)
|
|
| Siemens | Teamcenter Visualization V2312 |
Affected:
0 , < V2312.0008
(custom)
|
|
| Siemens | Teamcenter Visualization V2406 |
Affected:
0 , < V2406.0003
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-37996",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-15T18:31:15.685735Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T20:42:54.503Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T04:04:24.762Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-824889.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT Open",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0003",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PLM XML SDK",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.1.0.014",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0008",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0003",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT Open (All versions \u003c V11.5), JT2Go (All versions \u003c V2406.0003), PLM XML SDK (All versions \u003c V7.1.0.014), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.13), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.11), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Teamcenter Visualization V2406 (All versions \u003c V2406.0003). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted XML files. An attacker could leverage this vulnerability to crash the application causing denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476: NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-08T08:40:13.781Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-824889.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-959281.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-37996",
"datePublished": "2024-07-09T12:05:04.781Z",
"dateReserved": "2024-06-11T08:32:52.184Z",
"dateUpdated": "2025-08-27T20:42:54.503Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-34086 (GCVE-0-2024-34086)
Vulnerability from cvelistv5 – Published: 2024-05-14 10:03 – Updated: 2024-08-02 02:42
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0001), Teamcenter Visualization V14.1 (All versions < V14.1.0.13), Teamcenter Visualization V14.2 (All versions < V14.2.0.10), Teamcenter Visualization V14.3 (All versions < V14.3.0.7), Teamcenter Visualization V2312 (All versions < V2312.0001). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted CGM file.
This could allow an attacker to execute code in the context of the current process.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-14 15:19 UTC
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
1 reference
Impacted products
10 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < V2312.0001
(custom)
|
|
| Siemens | Teamcenter Visualization V14.1 |
Affected:
0 , < V14.1.0.13
(custom)
|
|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
0 , < V14.2.0.10
(custom)
|
|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.7
(custom)
|
|
| Siemens | Teamcenter Visualization V2312 |
Affected:
0 , < V2312.0001
(custom)
|
|
| siemens | jt2go |
Affected:
0 , < V2312.0001
(custom)
cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:* |
|
| siemens | teamcenter_visualization |
Affected:
0 , < V14.1.0.13
(custom)
cpe:2.3:a:siemens:teamcenter_visualization:14.1:*:*:*:*:*:*:* |
|
| siemens | teamcenter_visualization |
Affected:
0 , < 14.2.0.10
(custom)
cpe:2.3:a:siemens:teamcenter_visualization:14.2:*:*:*:*:*:*:* |
|
| siemens | teamcenter_visualization |
Affected:
0 , < V2312.0001
(custom)
cpe:2.3:a:siemens:teamcenter_visualization:2312:*:*:*:*:*:*:* |
|
| siemens | teamcenter_visualization |
Affected:
0 , < 14.3.0.7
(custom)
cpe:2.3:a:siemens:teamcenter_visualization:14.3:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "jt2go",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2312.0001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:14.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "V14.1.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:14.2:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "14.2.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:2312:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2312.0001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:14.3:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "14.3.0.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-34086",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T15:19:05.198442Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T18:22:25.821Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:42:59.863Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-661579.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.1.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0001), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.13), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.10), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.7), Teamcenter Visualization V2312 (All versions \u003c V2312.0001). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted CGM file.\r\nThis could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-15T07:24:55.854Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-661579.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-34086",
"datePublished": "2024-05-14T10:03:10.774Z",
"dateReserved": "2024-04-30T09:05:07.900Z",
"dateUpdated": "2024-08-02T02:42:59.863Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-34085 (GCVE-0-2024-34085)
Vulnerability from cvelistv5 – Published: 2024-05-14 10:03 – Updated: 2024-08-02 02:42
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0001), Teamcenter Visualization V14.1 (All versions < V14.1.0.13), Teamcenter Visualization V14.2 (All versions < V14.2.0.10), Teamcenter Visualization V14.3 (All versions < V14.3.0.7), Teamcenter Visualization V2312 (All versions < V2312.0001). The affected applications contain a stack overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-14 14:07 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
1 reference
Impacted products
9 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < V2312.0001
(custom)
|
|
| Siemens | Teamcenter Visualization V14.1 |
Affected:
0 , < V14.1.0.13
(custom)
|
|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
0 , < V14.2.0.10
(custom)
|
|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.7
(custom)
|
|
| Siemens | Teamcenter Visualization V2312 |
Affected:
0 , < V2312.0001
(custom)
|
|
| siemens | teamcenter_visualization |
Affected:
14.1 , < 14.1.0.13
(custom)
cpe:2.3:a:siemens:teamcenter_visualization:14.1:*:*:*:*:*:*:* |
|
| siemens | teamcenter_visualization |
Affected:
14.2 , < 14.2.0.10
(custom)
cpe:2.3:a:siemens:teamcenter_visualization:14.2:*:*:*:*:*:*:* |
|
| siemens | jt2go |
Affected:
0 , < 2312.0001
(custom)
cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:* |
|
| siemens | teamcenter_visualization |
Affected:
2312 , < 2312.0001
(custom)
cpe:2.3:a:siemens:teamcenter_visualization:2312:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:14.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "14.1.0.13",
"status": "affected",
"version": "14.1",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:14.2:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "14.2.0.10",
"status": "affected",
"version": "14.2",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "jt2go",
"vendor": "siemens",
"versions": [
{
"lessThan": "2312.0001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:2312:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "2312.0001",
"status": "affected",
"version": "2312",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-34085",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T14:07:42.511828Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T18:03:43.492Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:42:59.891Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-661579.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.1.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0001), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.13), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.10), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.7), Teamcenter Visualization V2312 (All versions \u003c V2312.0001). The affected applications contain a stack overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-15T07:24:54.668Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-661579.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-34085",
"datePublished": "2024-05-14T10:03:09.574Z",
"dateReserved": "2024-04-30T09:05:07.900Z",
"dateUpdated": "2024-08-02T02:42:59.891Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-32637 (GCVE-0-2024-32637)
Vulnerability from cvelistv5 – Published: 2024-05-14 10:02 – Updated: 2024-08-13 07:54
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0005), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.10), Teamcenter Visualization V2312 (All versions < V2312.0005). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-14 13:37 UTC
CWE
- CWE-476 - NULL Pointer Dereference
Assigner
References
Impacted products
5 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < V2312.0005
(custom)
|
|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
0 , < V14.2.0.12
(custom)
|
|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.10
(custom)
|
|
| Siemens | Teamcenter Visualization V2312 |
Affected:
0 , < V2312.0005
(custom)
|
|
| siemens | ps_iges_parasolid_translator_component |
Affected:
0 , < v27.1.215
(custom)
cpe:2.3:a:siemens:ps_iges_parasolid_translator_component:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:ps_iges_parasolid_translator_component:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ps_iges_parasolid_translator_component",
"vendor": "siemens",
"versions": [
{
"lessThan": "v27.1.215 ",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-32637",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T13:37:33.414539Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-18T18:07:35.849Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:13:40.086Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0005), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.10), Teamcenter Visualization V2312 (All versions \u003c V2312.0005). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476: NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-13T07:54:07.678Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-856475.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-32637",
"datePublished": "2024-05-14T10:02:44.682Z",
"dateReserved": "2024-04-16T10:52:15.707Z",
"dateUpdated": "2024-08-13T07:54:07.678Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-32636 (GCVE-0-2024-32636)
Vulnerability from cvelistv5 – Published: 2024-05-14 10:02 – Updated: 2024-08-13 07:54
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0005), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.10), Teamcenter Visualization V2312 (All versions < V2312.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-14 13:37 UTC
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < V2312.0005
(custom)
|
|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
0 , < V14.2.0.12
(custom)
|
|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.10
(custom)
|
|
| Siemens | Teamcenter Visualization V2312 |
Affected:
0 , < V2312.0005
(custom)
|
|
| siemens | parasolid |
Affected:
35.1 , < 35.1.256
(custom)
cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:* |
|
| siemens | parasolid |
Affected:
36.0 , < 36.0.208
(custom)
cpe:2.3:a:siemens:parasolid:36.0:*:*:*:*:*:*:* |
|
| siemens | parasolid |
Affected:
36.1 , < 36.1.173
(custom)
cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "35.1.256",
"status": "affected",
"version": "35.1",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.0.208",
"status": "affected",
"version": "36.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.1.173",
"status": "affected",
"version": "36.1",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-32636",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T13:37:41.622204Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:29:19.950Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:13:40.376Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0005), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.10), Teamcenter Visualization V2312 (All versions \u003c V2312.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-13T07:54:06.352Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-856475.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-32636",
"datePublished": "2024-05-14T10:02:43.480Z",
"dateReserved": "2024-04-16T10:52:15.707Z",
"dateUpdated": "2024-08-13T07:54:06.352Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-32635 (GCVE-0-2024-32635)
Vulnerability from cvelistv5 – Published: 2024-05-14 10:02 – Updated: 2024-08-13 07:54
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0005), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.10), Teamcenter Visualization V2312 (All versions < V2312.0005). The affected applications contain an out of bounds read past the unmapped memory region while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-14 13:37 UTC
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < V2312.0005
(custom)
|
|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
0 , < V14.2.0.12
(custom)
|
|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.10
(custom)
|
|
| Siemens | Teamcenter Visualization V2312 |
Affected:
0 , < V2312.0005
(custom)
|
|
| siemens | parasolid |
Affected:
35.1 , < 35.1.256
(custom)
cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:* |
|
| siemens | parasolid |
Affected:
36.0 , < 36.0.208
(custom)
cpe:2.3:a:siemens:parasolid:36.0:*:*:*:*:*:*:* |
|
| siemens | parasolid |
Affected:
36.1 , < 36.1.173
(custom)
cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "35.1.256",
"status": "affected",
"version": "35.1",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.0.208",
"status": "affected",
"version": "36.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.1.173",
"status": "affected",
"version": "36.1",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-32635",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T13:37:49.970409Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:27:51.096Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:13:40.417Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0005), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.10), Teamcenter Visualization V2312 (All versions \u003c V2312.0005). The affected applications contain an out of bounds read past the unmapped memory region while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-13T07:54:05.071Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-856475.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-32635",
"datePublished": "2024-05-14T10:02:42.291Z",
"dateReserved": "2024-04-16T10:52:15.707Z",
"dateUpdated": "2024-08-13T07:54:05.071Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-26277 (GCVE-0-2024-26277)
Vulnerability from cvelistv5 – Published: 2024-04-09 08:34 – Updated: 2024-08-13 07:54
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0004), Parasolid V35.1 (All versions < V35.1.254), Parasolid V36.0 (All versions < V36.0.207), Parasolid V36.1 (All versions < V36.1.147), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-04-09 19:51 UTC
CWE
- CWE-476 - NULL Pointer Dereference
Assigner
References
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < V2312.0004
(custom)
|
|
| Siemens | Parasolid V35.1 |
Affected:
0 , < V35.1.254
(custom)
|
|
| Siemens | Parasolid V36.0 |
Affected:
0 , < V36.0.207
(custom)
|
|
| Siemens | Parasolid V36.1 |
Affected:
0 , < V36.1.147
(custom)
|
|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
0 , < V14.2.0.12
(custom)
|
|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.9
(custom)
|
|
| Siemens | Teamcenter Visualization V2312 |
Affected:
0 , < V2312.0004
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-26277",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-09T19:51:56.120704Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:49:18.998Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T00:07:18.954Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V35.1.254",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.0.207",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.1.147",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0004), Parasolid V35.1 (All versions \u003c V35.1.254), Parasolid V36.0 (All versions \u003c V36.0.207), Parasolid V36.1 (All versions \u003c V36.1.147), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.9), Teamcenter Visualization V2312 (All versions \u003c V2312.0004). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476: NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-13T07:54:03.735Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-26277",
"datePublished": "2024-04-09T08:34:38.896Z",
"dateReserved": "2024-02-15T10:54:03.168Z",
"dateUpdated": "2024-08-13T07:54:03.735Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-26276 (GCVE-0-2024-26276)
Vulnerability from cvelistv5 – Published: 2024-04-09 08:34 – Updated: 2024-08-13 07:54
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0004), Parasolid V35.1 (All versions < V35.1.254), Parasolid V36.0 (All versions < V36.0.207), Parasolid V36.1 (All versions < V36.1.147), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected application contains a stack exhaustion vulnerability while parsing a specially crafted X_T file. This could allow an attacker to cause denial of service condition.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-14 13:40 UTC
CWE
- CWE-770 - Allocation of Resources Without Limits or Throttling
Assigner
References
Impacted products
10 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < V2312.0004
(custom)
|
|
| Siemens | Parasolid V35.1 |
Affected:
0 , < V35.1.254
(custom)
|
|
| Siemens | Parasolid V36.0 |
Affected:
0 , < V36.0.207
(custom)
|
|
| Siemens | Parasolid V36.1 |
Affected:
0 , < V36.1.147
(custom)
|
|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
0 , < V14.2.0.12
(custom)
|
|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.9
(custom)
|
|
| Siemens | Teamcenter Visualization V2312 |
Affected:
0 , < V2312.0004
(custom)
|
|
| siemens | parasolid |
Affected:
35.1 , < 35.1.254
(custom)
cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:* |
|
| siemens | parasolid |
Affected:
36.0 , < 36.0.207
(custom)
cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:* |
|
| siemens | parasolid |
Affected:
36.1 , < 36.1.147
(custom)
cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "35.1.254",
"status": "affected",
"version": "35.1",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.0.207",
"status": "affected",
"version": "36.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.1.147",
"status": "affected",
"version": "36.1",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-26276",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T13:40:25.505191Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T14:53:58.636Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T00:07:18.871Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V35.1.254",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.0.207",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.1.147",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0004), Parasolid V35.1 (All versions \u003c V35.1.254), Parasolid V36.0 (All versions \u003c V36.0.207), Parasolid V36.1 (All versions \u003c V36.1.147), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.9), Teamcenter Visualization V2312 (All versions \u003c V2312.0004). The affected application contains a stack exhaustion vulnerability while parsing a specially crafted X_T file. This could allow an attacker to cause denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-770",
"description": "CWE-770: Allocation of Resources Without Limits or Throttling",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-13T07:54:02.376Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-26276",
"datePublished": "2024-04-09T08:34:37.744Z",
"dateReserved": "2024-02-15T10:54:03.168Z",
"dateUpdated": "2024-08-13T07:54:02.376Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-26275 (GCVE-0-2024-26275)
Vulnerability from cvelistv5 – Published: 2024-04-09 08:34 – Updated: 2024-08-13 07:54
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0004), Parasolid V35.1 (All versions < V35.1.254), Parasolid V36.0 (All versions < V36.0.207), Parasolid V36.1 (All versions < V36.1.147), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-04-09 15:24 UTC
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
10 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < V2312.0004
(custom)
|
|
| Siemens | Parasolid V35.1 |
Affected:
0 , < V35.1.254
(custom)
|
|
| Siemens | Parasolid V36.0 |
Affected:
0 , < V36.0.207
(custom)
|
|
| Siemens | Parasolid V36.1 |
Affected:
0 , < V36.1.147
(custom)
|
|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
0 , < V14.2.0.12
(custom)
|
|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.9
(custom)
|
|
| Siemens | Teamcenter Visualization V2312 |
Affected:
0 , < V2312.0004
(custom)
|
|
| siemens | jt2go |
Affected:
0 , < 2312.0004
(custom)
cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:* |
|
| siemens | parasolid |
Affected:
0 , < 35.1.254
(custom)
Affected: 0 , < 36.0.207 (custom) Affected: 0 , < 36.1.147 (custom) cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:* |
|
| siemens | teamcenter_visualization |
Affected:
14.2 , < *
(custom)
Affected: 14.3 , < 14.3.0.9 (custom) Affected: 2312 , < 2312.0004 (custom) cpe:2.3:a:siemens:teamcenter_visualization:14.2:*:*:*:*:*:*:* cpe:2.3:a:siemens:teamcenter_visualization:14.3:*:*:*:*:*:*:* cpe:2.3:a:siemens:teamcenter_visualization:2312:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "jt2go",
"vendor": "siemens",
"versions": [
{
"lessThan": "2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "35.1.254",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "36.0.207",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "36.1.147",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:14.2:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:teamcenter_visualization:14.3:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:teamcenter_visualization:2312:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "14.2",
"versionType": "custom"
},
{
"lessThan": "14.3.0.9",
"status": "affected",
"version": "14.3",
"versionType": "custom"
},
{
"lessThan": "2312.0004",
"status": "affected",
"version": "2312",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-26275",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-09T15:24:40.222186Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-31T18:33:02.344Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T00:07:19.343Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V35.1.254",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.0.207",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.1.147",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0004), Parasolid V35.1 (All versions \u003c V35.1.254), Parasolid V36.0 (All versions \u003c V36.0.207), Parasolid V36.1 (All versions \u003c V36.1.147), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.9), Teamcenter Visualization V2312 (All versions \u003c V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-13T07:54:00.911Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-26275",
"datePublished": "2024-04-09T08:34:36.604Z",
"dateReserved": "2024-02-15T10:54:03.168Z",
"dateUpdated": "2024-08-13T07:54:00.911Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-51746 (GCVE-0-2023-51746)
Vulnerability from cvelistv5 – Published: 2024-01-09 10:00 – Updated: 2024-09-04 15:14
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.6), Teamcenter Visualization V13.3 (All versions < V13.3.0.13), Teamcenter Visualization V14.1 (All versions < V14.1.0.12), Teamcenter Visualization V14.2 (All versions < V14.2.0.9), Teamcenter Visualization V14.3 (All versions < V14.3.0.6). The affected applications contain a stack overflow vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-04 15:13 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
1 reference
Impacted products
5 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V14.3.0.6
|
|
| Siemens | Teamcenter Visualization V13.3 |
Affected:
All versions < V13.3.0.13
|
|
| Siemens | Teamcenter Visualization V14.1 |
Affected:
All versions < V14.1.0.12
|
|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
All versions < V14.2.0.9
|
|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
All versions < V14.3.0.6
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T22:48:11.101Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-794653.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-51746",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-04T15:13:57.367529Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-04T15:14:05.889Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.13"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.9"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.6), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.13), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.12), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.9), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.6). The affected applications contain a stack overflow vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-09T10:00:18.333Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-794653.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-51746",
"datePublished": "2024-01-09T10:00:18.333Z",
"dateReserved": "2023-12-22T11:30:22.672Z",
"dateUpdated": "2024-09-04T15:14:05.889Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-51745 (GCVE-0-2023-51745)
Vulnerability from cvelistv5 – Published: 2024-01-09 10:00 – Updated: 2025-06-03 14:31
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.6), Teamcenter Visualization V13.3 (All versions < V13.3.0.13), Teamcenter Visualization V14.1 (All versions < V14.1.0.12), Teamcenter Visualization V14.2 (All versions < V14.2.0.9), Teamcenter Visualization V14.3 (All versions < V14.3.0.6). The affected applications contain a stack overflow vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-05-08 18:45 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
1 reference
Impacted products
5 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V14.3.0.6
|
|
| Siemens | Teamcenter Visualization V13.3 |
Affected:
All versions < V13.3.0.13
|
|
| Siemens | Teamcenter Visualization V14.1 |
Affected:
All versions < V14.1.0.12
|
|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
All versions < V14.2.0.9
|
|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
All versions < V14.3.0.6
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T22:40:34.255Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-794653.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-51745",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-08T18:45:55.954048Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-03T14:31:19.908Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.13"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.9"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.6), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.13), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.12), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.9), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.6). The affected applications contain a stack overflow vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-09T10:00:17.032Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-794653.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-51745",
"datePublished": "2024-01-09T10:00:17.032Z",
"dateReserved": "2023-12-22T11:30:22.671Z",
"dateUpdated": "2025-06-03T14:31:19.908Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}