Search
Find a vulnerability
Search criteria
8 vulnerabilities found for F1202 by Tenda
CVE-2026-9431 (GCVE-0-2026-9431)
Vulnerability from nvd – Published: 2026-05-25 05:45 – Updated: 2026-05-26 13:12
VLAI
EPSS
VEX
Title
Tenda F1202 PptpUserAdd fromPptpUserAdd stack-based overflow
Summary
A vulnerability was identified in Tenda F1202 1.2.0.20(408). This affects the function fromPptpUserAdd of the file /goform/PptpUserAdd. The manipulation of the argument opttype leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit is publicly available and might be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-05-26 13:12 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/365412 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/365412/cti | signaturepermissions-required |
| https://vuldb.com/submit/813916 | third-party-advisory |
| https://github.com/Litengzheng/vuldb_new2/blob/ma… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-9431",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-26T13:12:02.867879Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-26T13:12:09.259Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*"
],
"product": "F1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.20(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHuster2 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was identified in Tenda F1202 1.2.0.20(408). This affects the function fromPptpUserAdd of the file /goform/PptpUserAdd. The manipulation of the argument opttype leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit is publicly available and might be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-25T05:45:10.169Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-365412 | Tenda F1202 PptpUserAdd fromPptpUserAdd stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/365412"
},
{
"name": "VDB-365412 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/365412/cti"
},
{
"name": "Submit #813916 | Tenda F1202 V1.2.0.20(408) Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/813916"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vuldb_new2/blob/main/F1202/vul_35/README.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-05-24T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-05-24T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-05-24T09:08:50.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda F1202 PptpUserAdd fromPptpUserAdd stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-9431",
"datePublished": "2026-05-25T05:45:10.169Z",
"dateReserved": "2026-05-24T07:03:29.836Z",
"dateUpdated": "2026-05-26T13:12:09.259Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-9430 (GCVE-0-2026-9430)
Vulnerability from nvd – Published: 2026-05-25 05:30 – Updated: 2026-05-28 12:38
VLAI
EPSS
VEX
Title
Tenda F1202 GstDhcpSetSerof formGstDhcpSetSer stack-based overflow
Summary
A vulnerability was determined in Tenda F1202 1.2.0.20(408). Affected by this issue is the function formGstDhcpSetSer of the file /goform/GstDhcpSetSerof. Executing a manipulation of the argument dips can lead to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been publicly disclosed and may be utilized.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-05-28 12:37 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/365411 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/365411/cti | signaturepermissions-required |
| https://vuldb.com/submit/813915 | third-party-advisory |
| https://github.com/Litengzheng/vuldb_new2/blob/ma… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-9430",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-28T12:37:19.410093Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-28T12:38:04.357Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*"
],
"product": "F1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.20(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHuster2 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was determined in Tenda F1202 1.2.0.20(408). Affected by this issue is the function formGstDhcpSetSer of the file /goform/GstDhcpSetSerof. Executing a manipulation of the argument dips can lead to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been publicly disclosed and may be utilized."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-25T05:30:12.026Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-365411 | Tenda F1202 GstDhcpSetSerof formGstDhcpSetSer stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/365411"
},
{
"name": "VDB-365411 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/365411/cti"
},
{
"name": "Submit #813915 | Tenda F1202 V1.2.0.20(408) Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/813915"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vuldb_new2/blob/main/F1202/vul_32/README.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-05-24T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-05-24T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-05-24T09:08:48.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda F1202 GstDhcpSetSerof formGstDhcpSetSer stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-9430",
"datePublished": "2026-05-25T05:30:12.026Z",
"dateReserved": "2026-05-24T07:03:24.648Z",
"dateUpdated": "2026-05-28T12:38:04.357Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-9429 (GCVE-0-2026-9429)
Vulnerability from nvd – Published: 2026-05-25 05:15 – Updated: 2026-05-26 16:05
VLAI
EPSS
VEX
Title
Tenda F1202 WrlExtraSet formWrlExtraSet stack-based overflow
Summary
A vulnerability was found in Tenda F1202 1.2.0.20(408). Affected by this vulnerability is the function formWrlExtraSet of the file /goform/WrlExtraSet. Performing a manipulation of the argument delno results in stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been made public and could be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-05-26 16:05 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/365410 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/365410/cti | signaturepermissions-required |
| https://vuldb.com/submit/813912 | third-party-advisory |
| https://github.com/Litengzheng/vuldb_new2/blob/ma… | exploit |
| https://www.tenda.com.cn/ | broken-linkproduct |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-9429",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-26T16:05:34.410649Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-26T16:05:41.704Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*"
],
"product": "F1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.20(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHuster2 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda F1202 1.2.0.20(408). Affected by this vulnerability is the function formWrlExtraSet of the file /goform/WrlExtraSet. Performing a manipulation of the argument delno results in stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been made public and could be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-25T05:15:09.759Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-365410 | Tenda F1202 WrlExtraSet formWrlExtraSet stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/365410"
},
{
"name": "VDB-365410 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/365410/cti"
},
{
"name": "Submit #813912 | Tenda F1202 V1.2.0.20(408) Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/813912"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vuldb_new2/blob/main/F1202/vul_31/README.md"
},
{
"tags": [
"broken-link",
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-05-24T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-05-24T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-05-24T09:08:41.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda F1202 WrlExtraSet formWrlExtraSet stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-9429",
"datePublished": "2026-05-25T05:15:09.759Z",
"dateReserved": "2026-05-24T07:03:22.153Z",
"dateUpdated": "2026-05-26T16:05:41.704Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-9428 (GCVE-0-2026-9428)
Vulnerability from nvd – Published: 2026-05-25 05:00 – Updated: 2026-05-28 18:37
VLAI
EPSS
VEX
Title
Tenda F1202 PPTPUserSetting fromPPTPUserSetting stack-based overflow
Summary
A vulnerability has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromPPTPUserSetting of the file /goform/PPTPUserSetting. Such manipulation of the argument delno leads to stack-based buffer overflow. The attack may be performed from remote. The exploit has been disclosed to the public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-05-28 18:36 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/365409 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/365409/cti | signaturepermissions-required |
| https://vuldb.com/submit/813911 | third-party-advisory |
| https://github.com/Litengzheng/vuldb_new2/blob/ma… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-9428",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-28T18:36:36.235807Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-28T18:37:05.367Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*"
],
"product": "F1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.20(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHuster2 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromPPTPUserSetting of the file /goform/PPTPUserSetting. Such manipulation of the argument delno leads to stack-based buffer overflow. The attack may be performed from remote. The exploit has been disclosed to the public and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-25T05:00:14.895Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-365409 | Tenda F1202 PPTPUserSetting fromPPTPUserSetting stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/365409"
},
{
"name": "VDB-365409 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/365409/cti"
},
{
"name": "Submit #813911 | Tenda F1202 V1.2.0.20(408) Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/813911"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vuldb_new2/blob/main/F1202/vul_29/README.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-05-24T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-05-24T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-05-24T09:08:38.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda F1202 PPTPUserSetting fromPPTPUserSetting stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-9428",
"datePublished": "2026-05-25T05:00:14.895Z",
"dateReserved": "2026-05-24T07:03:19.502Z",
"dateUpdated": "2026-05-28T18:37:05.367Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-9431 (GCVE-0-2026-9431)
Vulnerability from cvelistv5 – Published: 2026-05-25 05:45 – Updated: 2026-05-26 13:12
VLAI
EPSS
VEX
Title
Tenda F1202 PptpUserAdd fromPptpUserAdd stack-based overflow
Summary
A vulnerability was identified in Tenda F1202 1.2.0.20(408). This affects the function fromPptpUserAdd of the file /goform/PptpUserAdd. The manipulation of the argument opttype leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit is publicly available and might be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-05-26 13:12 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/365412 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/365412/cti | signaturepermissions-required |
| https://vuldb.com/submit/813916 | third-party-advisory |
| https://github.com/Litengzheng/vuldb_new2/blob/ma… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-9431",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-26T13:12:02.867879Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-26T13:12:09.259Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*"
],
"product": "F1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.20(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHuster2 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was identified in Tenda F1202 1.2.0.20(408). This affects the function fromPptpUserAdd of the file /goform/PptpUserAdd. The manipulation of the argument opttype leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit is publicly available and might be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-25T05:45:10.169Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-365412 | Tenda F1202 PptpUserAdd fromPptpUserAdd stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/365412"
},
{
"name": "VDB-365412 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/365412/cti"
},
{
"name": "Submit #813916 | Tenda F1202 V1.2.0.20(408) Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/813916"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vuldb_new2/blob/main/F1202/vul_35/README.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-05-24T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-05-24T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-05-24T09:08:50.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda F1202 PptpUserAdd fromPptpUserAdd stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-9431",
"datePublished": "2026-05-25T05:45:10.169Z",
"dateReserved": "2026-05-24T07:03:29.836Z",
"dateUpdated": "2026-05-26T13:12:09.259Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-9430 (GCVE-0-2026-9430)
Vulnerability from cvelistv5 – Published: 2026-05-25 05:30 – Updated: 2026-05-28 12:38
VLAI
EPSS
VEX
Title
Tenda F1202 GstDhcpSetSerof formGstDhcpSetSer stack-based overflow
Summary
A vulnerability was determined in Tenda F1202 1.2.0.20(408). Affected by this issue is the function formGstDhcpSetSer of the file /goform/GstDhcpSetSerof. Executing a manipulation of the argument dips can lead to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been publicly disclosed and may be utilized.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-05-28 12:37 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/365411 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/365411/cti | signaturepermissions-required |
| https://vuldb.com/submit/813915 | third-party-advisory |
| https://github.com/Litengzheng/vuldb_new2/blob/ma… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-9430",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-28T12:37:19.410093Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-28T12:38:04.357Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*"
],
"product": "F1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.20(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHuster2 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was determined in Tenda F1202 1.2.0.20(408). Affected by this issue is the function formGstDhcpSetSer of the file /goform/GstDhcpSetSerof. Executing a manipulation of the argument dips can lead to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been publicly disclosed and may be utilized."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-25T05:30:12.026Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-365411 | Tenda F1202 GstDhcpSetSerof formGstDhcpSetSer stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/365411"
},
{
"name": "VDB-365411 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/365411/cti"
},
{
"name": "Submit #813915 | Tenda F1202 V1.2.0.20(408) Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/813915"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vuldb_new2/blob/main/F1202/vul_32/README.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-05-24T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-05-24T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-05-24T09:08:48.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda F1202 GstDhcpSetSerof formGstDhcpSetSer stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-9430",
"datePublished": "2026-05-25T05:30:12.026Z",
"dateReserved": "2026-05-24T07:03:24.648Z",
"dateUpdated": "2026-05-28T12:38:04.357Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-9429 (GCVE-0-2026-9429)
Vulnerability from cvelistv5 – Published: 2026-05-25 05:15 – Updated: 2026-05-26 16:05
VLAI
EPSS
VEX
Title
Tenda F1202 WrlExtraSet formWrlExtraSet stack-based overflow
Summary
A vulnerability was found in Tenda F1202 1.2.0.20(408). Affected by this vulnerability is the function formWrlExtraSet of the file /goform/WrlExtraSet. Performing a manipulation of the argument delno results in stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been made public and could be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-05-26 16:05 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/365410 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/365410/cti | signaturepermissions-required |
| https://vuldb.com/submit/813912 | third-party-advisory |
| https://github.com/Litengzheng/vuldb_new2/blob/ma… | exploit |
| https://www.tenda.com.cn/ | broken-linkproduct |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-9429",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-26T16:05:34.410649Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-26T16:05:41.704Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*"
],
"product": "F1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.20(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHuster2 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda F1202 1.2.0.20(408). Affected by this vulnerability is the function formWrlExtraSet of the file /goform/WrlExtraSet. Performing a manipulation of the argument delno results in stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been made public and could be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-25T05:15:09.759Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-365410 | Tenda F1202 WrlExtraSet formWrlExtraSet stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/365410"
},
{
"name": "VDB-365410 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/365410/cti"
},
{
"name": "Submit #813912 | Tenda F1202 V1.2.0.20(408) Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/813912"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vuldb_new2/blob/main/F1202/vul_31/README.md"
},
{
"tags": [
"broken-link",
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-05-24T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-05-24T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-05-24T09:08:41.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda F1202 WrlExtraSet formWrlExtraSet stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-9429",
"datePublished": "2026-05-25T05:15:09.759Z",
"dateReserved": "2026-05-24T07:03:22.153Z",
"dateUpdated": "2026-05-26T16:05:41.704Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-9428 (GCVE-0-2026-9428)
Vulnerability from cvelistv5 – Published: 2026-05-25 05:00 – Updated: 2026-05-28 18:37
VLAI
EPSS
VEX
Title
Tenda F1202 PPTPUserSetting fromPPTPUserSetting stack-based overflow
Summary
A vulnerability has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromPPTPUserSetting of the file /goform/PPTPUserSetting. Such manipulation of the argument delno leads to stack-based buffer overflow. The attack may be performed from remote. The exploit has been disclosed to the public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-05-28 18:36 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/365409 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/365409/cti | signaturepermissions-required |
| https://vuldb.com/submit/813911 | third-party-advisory |
| https://github.com/Litengzheng/vuldb_new2/blob/ma… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-9428",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-28T18:36:36.235807Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-28T18:37:05.367Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*"
],
"product": "F1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.20(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHuster2 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromPPTPUserSetting of the file /goform/PPTPUserSetting. Such manipulation of the argument delno leads to stack-based buffer overflow. The attack may be performed from remote. The exploit has been disclosed to the public and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-25T05:00:14.895Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-365409 | Tenda F1202 PPTPUserSetting fromPPTPUserSetting stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/365409"
},
{
"name": "VDB-365409 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/365409/cti"
},
{
"name": "Submit #813911 | Tenda F1202 V1.2.0.20(408) Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/813911"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vuldb_new2/blob/main/F1202/vul_29/README.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-05-24T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-05-24T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-05-24T09:08:38.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda F1202 PPTPUserSetting fromPPTPUserSetting stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-9428",
"datePublished": "2026-05-25T05:00:14.895Z",
"dateReserved": "2026-05-24T07:03:19.502Z",
"dateUpdated": "2026-05-28T18:37:05.367Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}