Search

Find a vulnerability

Search criteria

    10 vulnerabilities found for Control for PFC200 SL by CODESYS

    CVE-2026-79625 (GCVE-0-2026-79625)

    Vulnerability from nvd – Published: 2026-09-30 09:23 – Updated: 2026-09-30 13:49
    VLAI
    Title
    Improper Synchronization in Monitoring in CODESYS Control Runtime
    Summary
    Affected products do not properly synchronize access to their monitoring functionality. When multiple clients send concurrent requests, this may lead to incorrect reads or writes, or to corruption of internal memory structures. An authenticated remote attacker with monitoring access can exploit this issue to cause incorrect data processing or a denial-of-service condition.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-30 13:49 UTC
    CWE
    • CWE-362 - Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition')
    References
    Impacted products
    Vendor Product Version
    CODESYS Control RTE (SL) Affected: 3.0.0.0 , < 3.5.22.40 (semver)
    Create a notification for this product.
    CODESYS Control RTE (for Beckhoff CX) SL Affected: 3.0.0.0 , < 3.5.22.40 (semver)
    Create a notification for this product.
    CODESYS Control Win (SL) Affected: 3.0.0.0 , < 3.5.22.40 (semver)
    Create a notification for this product.
    CODESYS Runtime Toolkit Affected: 3.0.0.0 , < 3.5.22.40 (semver)
    Create a notification for this product.
    CODESYS Safety SIL2 Affected: 3.0.0.0 , < 3.5.22.40 (semver)
    Create a notification for this product.
    CODESYS HMI (SL) Affected: 3.0.0.0 , < 3.5.22.40 (semver)
    Create a notification for this product.
    CODESYS Development System 3 Affected: 3.0.0.0 , < 3.5.22.40 (semver)
    Create a notification for this product.
    CODESYS Control for BeagleBone SL Affected: 3.5.0.0 , < 4.23.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for emPC-A/iMX6 SL Affected: 3.5.0.0 , < 4.23.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for IOT2000 SL Affected: 3.5.0.0 , < 4.23.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for Linux ARM SL Affected: 3.5.0.0 , < 4.23.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for Linux SL Affected: 3.5.0.0 , < 4.23.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for PFC100 SL Affected: 3.5.0.0 , < 4.23.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for PFC200 SL Affected: 3.5.0.0 , < 4.23.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for PLCnext SL Affected: 3.5.0.0 , < 4.23.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for Raspberry Pi SL Affected: 3.5.0.0 , < 4.23.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for WAGO Touch Panels 600 SL Affected: 3.5.0.0 , < 4.23.0.0 (semver)
    Create a notification for this product.
    CODESYS Virtual Control SL Affected: 3.5.0.0 , < 4.23.0.0 (semver)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-79625",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-30T13:49:04.420443Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-30T13:49:14.992Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Control RTE (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.22.40",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control RTE (for Beckhoff CX) SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.22.40",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control Win (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.22.40",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Runtime Toolkit",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.22.40",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Safety SIL2",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.22.40",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "HMI (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.22.40",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Development System 3",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.22.40",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for BeagleBone SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.23.0.0",
                  "status": "affected",
                  "version": "3.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for emPC-A/iMX6 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.23.0.0",
                  "status": "affected",
                  "version": "3.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for IOT2000 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.23.0.0",
                  "status": "affected",
                  "version": "3.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Linux ARM SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.23.0.0",
                  "status": "affected",
                  "version": "3.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Linux SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.23.0.0",
                  "status": "affected",
                  "version": "3.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PFC100 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.23.0.0",
                  "status": "affected",
                  "version": "3.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PFC200 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.23.0.0",
                  "status": "affected",
                  "version": "3.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PLCnext SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.23.0.0",
                  "status": "affected",
                  "version": "3.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Raspberry Pi SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.23.0.0",
                  "status": "affected",
                  "version": "3.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for WAGO Touch Panels 600 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.23.0.0",
                  "status": "affected",
                  "version": "3.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Virtual Control SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.23.0.0",
                  "status": "affected",
                  "version": "3.5.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eAffected products do not properly synchronize access to their monitoring functionality. When multiple clients send concurrent requests, this may lead to incorrect reads or writes, or to corruption of internal memory structures. An authenticated remote attacker with monitoring access can exploit this issue to cause incorrect data processing or a denial-of-service condition.\u003c/p\u003e"
                }
              ],
              "value": "Affected products do not properly synchronize access to their monitoring functionality. When multiple clients send concurrent requests, this may lead to incorrect reads or writes, or to corruption of internal memory structures. An authenticated remote attacker with monitoring access can exploit this issue to cause incorrect data processing or a denial-of-service condition."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-362",
                  "description": "CWE-362 Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-30T09:23:16.775Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-097/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-097",
            "defect": [
              "CERT@VDE#642221"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Improper Synchronization in Monitoring in CODESYS Control Runtime",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-79625",
        "datePublished": "2026-09-30T09:23:16.775Z",
        "dateReserved": "2026-08-25T08:46:38.207Z",
        "dateUpdated": "2026-09-30T13:49:14.992Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41691 (GCVE-0-2025-41691)

    Vulnerability from nvd – Published: 2025-08-04 08:04 – Updated: 2025-08-04 16:32
    VLAI
    Title
    CODESYS Control DoS via Unauthenticated NULL Pointer Dereference
    Summary
    An unauthenticated remote attacker may trigger a NULL pointer dereference in the affected CODESYS Control runtime systems by sending specially crafted communication requests, potentially leading to a denial-of-service (DoS) condition.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-08-04 16:28 UTC
    CWE
    • CWE-476 - NULL Pointer Dereference
    References
    Impacted products
    Vendor Product Version
    CODESYS Control RTE (SL) Affected: 3.5.21.10 , < 3.5.21.20 (semver)
    Create a notification for this product.
    CODESYS Control RTE (for Beckhoff CX) SL Affected: 3.5.21.10 , < 3.5.21.20 (semver)
    Create a notification for this product.
    CODESYS Control Win (SL) Affected: 3.5.21.10 , < 3.5.21.20 (semver)
    Create a notification for this product.
    CODESYS HMI (SL) Affected: 3.5.21.10 , < 3.5.21.20 (semver)
    Create a notification for this product.
    CODESYS Control for BeagleBone SL Affected: 4.16.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for emPC-A/iMX6 SL Affected: 4.16.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for IOT2000 SL Affected: 4.16.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for Linux ARM SL Affected: 4.16.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for Linux SL Affected: 4.16.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for PFC100 SL Affected: 4.16.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for PFC200 SL Affected: 4.16.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for PLCnext SL Affected: 4.16.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for Raspberry Pi SL Affected: 4.16.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for WAGO Touch Panels 600 SL Affected: 4.16.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Virtual Control SL Affected: 4.16.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41691",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-08-04T16:28:09.392670Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-04T16:32:30.773Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Control RTE (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.20",
                  "status": "affected",
                  "version": "3.5.21.10",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control RTE (for Beckhoff CX) SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.20",
                  "status": "affected",
                  "version": "3.5.21.10",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control Win (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.20",
                  "status": "affected",
                  "version": "3.5.21.10",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "HMI (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.20",
                  "status": "affected",
                  "version": "3.5.21.10",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for BeagleBone SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "4.16.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for emPC-A/iMX6 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "4.16.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for IOT2000 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "4.16.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Linux ARM SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "4.16.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Linux SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "4.16.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PFC100 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "4.16.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PFC200 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "4.16.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PLCnext SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "4.16.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Raspberry Pi SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "4.16.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for WAGO Touch Panels 600 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "4.16.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Virtual Control SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "4.16.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An unauthenticated remote attacker may trigger a NULL pointer dereference in the affected CODESYS Control runtime systems by sending specially crafted communication requests, potentially leading to a denial-of-service (DoS) condition.\u003cbr\u003e"
                }
              ],
              "value": "An unauthenticated remote attacker may trigger a NULL pointer dereference in the affected CODESYS Control runtime systems by sending specially crafted communication requests, potentially leading to a denial-of-service (DoS) condition."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-476",
                  "description": "CWE-476 NULL Pointer Dereference",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-04T08:04:34.981Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/de/advisories/VDE-2025-070"
            }
          ],
          "source": {
            "advisory": "VDE-2025-070",
            "defect": [
              "CERT@VDE#641834"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "CODESYS Control DoS via Unauthenticated NULL Pointer Dereference",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-41691",
        "datePublished": "2025-08-04T08:04:34.981Z",
        "dateReserved": "2025-04-16T11:17:48.309Z",
        "dateUpdated": "2025-08-04T16:32:30.773Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-41659 (GCVE-0-2025-41659)

    Vulnerability from nvd – Published: 2025-08-04 08:04 – Updated: 2025-08-04 16:35
    VLAI
    Title
    CODESYS Control PKI Exposure Enables Remote Certificate Access
    Summary
    A low-privileged attacker can remotely access the PKI folder of the CODESYS Control runtime system and thus read and write certificates and its keys. This allows sensitive data to be extracted or to accept certificates as trusted. Although all services remain available, only unencrypted communication is possible if the certificates are deleted.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-08-04 16:34 UTC
    CWE
    • CWE-732 - Incorrect Permission Assignment for Critical Resource
    References
    Impacted products
    Vendor Product Version
    CODESYS Control RTE (SL) Affected: 0.0.0.0 , < 3.5.21.20 (semver)
    Create a notification for this product.
    CODESYS Control RTE (for Beckhoff CX) SL Affected: 0.0.0.0 , < 3.5.21.20 (semver)
    Create a notification for this product.
    CODESYS Control Win (SL) Affected: 0.0.0.0 , < 3.5.21.20 (semver)
    Create a notification for this product.
    CODESYS HMI (SL) Affected: 0.0.0.0 , < 3.5.21.20 (semver)
    Create a notification for this product.
    CODESYS Runtime Toolkit Affected: 0.0.0.0 , < 3.5.21.20 (semver)
    Create a notification for this product.
    CODESYS Control for BeagleBone SL Affected: 0.0.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for emPC-A/iMX6 SL Affected: 0.0.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for IOT2000 SL Affected: 0.0.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for Linux ARM SL Affected: 0.0.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for Linux SL Affected: 0.0.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for PFC100 SL Affected: 0.0.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for PFC200 SL Affected: 0.0.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for PLCnext SL Affected: 0.0.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for Raspberry Pi SL Affected: 0.0.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for WAGO Touch Panels 600 SL Affected: 0.0.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Virtual Control SL Affected: 0.0.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41659",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-08-04T16:34:47.316036Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-04T16:35:32.484Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Control RTE (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.20",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control RTE (for Beckhoff CX) SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.20",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control Win (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.20",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "HMI (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.20",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Runtime Toolkit",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.20",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for BeagleBone SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for emPC-A/iMX6 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for IOT2000 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Linux ARM SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Linux SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PFC100 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PFC200 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PLCnext SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Raspberry Pi SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for WAGO Touch Panels 600 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Virtual Control SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Luca Borzacchiello from Nozomi Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A low-privileged attacker can remotely access the PKI folder of the CODESYS Control runtime system and thus read and write certificates and its keys. This allows sensitive data to be extracted or to accept certificates as trusted. Although all services remain available, only unencrypted communication is possible if the certificates are deleted.\u003cbr\u003e"
                }
              ],
              "value": "A low-privileged attacker can remotely access the PKI folder of the CODESYS Control runtime system and thus read and write certificates and its keys. This allows sensitive data to be extracted or to accept certificates as trusted. Although all services remain available, only unencrypted communication is possible if the certificates are deleted."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-732",
                  "description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-04T08:04:04.597Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/de/advisories/VDE-2025-051"
            }
          ],
          "source": {
            "advisory": "VDE-2025-051",
            "defect": [
              "CERT@VDE#641801"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "CODESYS Control PKI Exposure Enables Remote Certificate Access",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-41659",
        "datePublished": "2025-08-04T08:04:04.597Z",
        "dateReserved": "2025-04-16T11:17:48.307Z",
        "dateUpdated": "2025-08-04T16:35:32.484Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-41658 (GCVE-0-2025-41658)

    Vulnerability from nvd – Published: 2025-08-04 08:03 – Updated: 2025-08-04 11:52
    VLAI
    Title
    CODESYS Toolkit Exposes Sensitive Files via Default Permissions
    Summary
    CODESYS Runtime Toolkit-based products may expose sensitive files to local low-privileged operating system users due to default file permissions.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-08-04 11:52 UTC
    CWE
    • CWE-276 - Incorrect Default Permissions
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41658",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-08-04T11:52:31.347383Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-04T11:52:37.949Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Runtime Toolkit",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.20",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for BeagleBone SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.16.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for emPC-A/iMX6 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.16.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for IOT2000 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.16.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Linux ARM SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.16.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Linux SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.16.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PFC100 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.16.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PFC200 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.16.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PLCnext SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.16.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Raspberry Pi SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.16.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for WAGO Touch Panels 600 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.16.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Virtual Control SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.16.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Luca Borzacchiello from Nozomi Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "CODESYS Runtime Toolkit-based products may expose sensitive files to local low-privileged operating system users due to default file permissions.\u003cbr\u003e"
                }
              ],
              "value": "CODESYS Runtime Toolkit-based products may expose sensitive files to local low-privileged operating system users due to default file permissions."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-276",
                  "description": "CWE-276 Incorrect Default Permissions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-04T08:03:26.511Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/de/advisories/VDE-2025-049"
            }
          ],
          "source": {
            "advisory": "VDE-2025-049",
            "defect": [
              "CERT@VDE#641799"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "CODESYS Toolkit Exposes Sensitive Files via Default Permissions",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-41658",
        "datePublished": "2025-08-04T08:03:26.511Z",
        "dateReserved": "2025-04-16T11:17:48.306Z",
        "dateUpdated": "2025-08-04T11:52:37.949Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-4224 (GCVE-0-2022-4224)

    Vulnerability from nvd – Published: 2023-03-23 11:15 – Updated: 2026-05-29 14:08
    VLAI
    Title
    CODESYS: Exposure of Resource to Wrong Sphere in CODESYS V3
    Summary
    In multiple products of CODESYS v3 in multiple versions a remote low privileged user could utilize this vulnerability to read and modify system files and OS resources or DoS the device.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-05-29 14:07 UTC
    CWE
    • CWE-1188 - Insecure Default Initialization of Resource
    Impacted products
    Vendor Product Version
    CODESYS Control RTE (SL) Affected: 3.0.0.0 , < 3.5.19.0 (custom)
    Create a notification for this product.
    CODESYS Control RTE (for Beckhoff CX) SL Affected: 3.0.0.0 , < 3.5.19.0 (custom)
    Create a notification for this product.
    CODESYS Control Win (SL) Affected: 3.0.0.0 , < 3.5.19.0 (custom)
    Create a notification for this product.
    CODESYS Runtime Toolkit Affected: 3.0.0.0 , < 3.5.19.0 (custom)
    Create a notification for this product.
    CODESYS Safety SIL2 Runtime Toolkit Affected: 3.0.0.0 , < 3.5.19.0 (custom)
    Create a notification for this product.
    CODESYS Safety SIL2 PSP Affected: 3.0.0.0 , < 3.5.19.0 (custom)
    Create a notification for this product.
    CODESYS HMI (SL) Affected: 3.0.0.0 , < 3.5.19.0 (custom)
    Create a notification for this product.
    CODESYS Development System V3 Affected: 3.0.0.0 , < 3.5.19.0 (custom)
    Create a notification for this product.
    CODESYS Control for BeagleBone SL Affected: 3.0.0.0 , < 4.8.0.0 (custom)
    Create a notification for this product.
    CODESYS Control for emPC-A/iMX6 SL Affected: 3.0.0.0 , < 4.8.0.0 (custom)
    Create a notification for this product.
    CODESYS Control for IOT2000 SL Affected: 3.0.0.0 , < 4.8.0.0 (custom)
    Create a notification for this product.
    CODESYS Control for Linux SL Affected: 3.0.0.0 , < 4.8.0.0 (custom)
    Create a notification for this product.
    CODESYS Control for PFC100 SL Affected: 3.0.0.0 , < 4.8.0.0 (custom)
    Create a notification for this product.
    CODESYS Control for PFC200 SL Affected: 3.0.0.0 , < 4.8.0.0 (custom)
    Create a notification for this product.
    CODESYS Control for PLCnext SL Affected: 3.0.0.0 , < 4.8.0.0 (custom)
    Create a notification for this product.
    CODESYS Control for Raspberry Pi SL Affected: 3.0.0.0 , < 4.8.0.0 (custom)
    Create a notification for this product.
    CODESYS Control for WAGO Touch Panels 600 SL Affected: 3.0.0.0 , < 4.8.0.0 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T01:34:49.591Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17553\u0026token=cf49757d232ea8021f0c0dd6c65e71ea5942b12d\u0026download="
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-4224",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T14:07:26.160566Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T14:08:13.754Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Control RTE (SL) ",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.19.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control RTE (for Beckhoff CX) SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.19.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control Win (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.19.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": " Runtime Toolkit ",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.19.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Safety SIL2 Runtime Toolkit",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.19.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Safety SIL2 PSP",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.19.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "HMI (SL) ",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.19.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Development System V3",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.19.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": " Control for BeagleBone SL ",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.8.0.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for emPC-A/iMX6 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.8.0.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for IOT2000 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.8.0.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Linux SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.8.0.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": " Control for PFC100 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.8.0.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": " Control for PFC200 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.8.0.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PLCnext SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.8.0.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Raspberry Pi SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.8.0.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for WAGO Touch Panels 600 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.8.0.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Franklin Zhao from ELEX FEIGONG RESEARCH INSTITUTE of Elex CyberSecurity"
            },
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Reid Wightman of Dragos"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "In multiple products of CODESYS v3 in multiple versions a remote low privileged user\u0026nbsp;could utilize this vulnerability to read and modify system files and OS resources or DoS the device."
                }
              ],
              "value": "In multiple products of CODESYS v3 in multiple versions a remote low privileged user\u00a0could utilize this vulnerability to read and modify system files and OS resources or DoS the device."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1188",
                  "description": "CWE-1188 Insecure Default Initialization of Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-09T10:47:13.144Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17553\u0026token=cf49757d232ea8021f0c0dd6c65e71ea5942b12d\u0026download="
            }
          ],
          "source": {
            "defect": [
              "CERT@VDE#64318"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "CODESYS:  Exposure of Resource to Wrong Sphere in CODESYS V3",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-4224",
        "datePublished": "2023-03-23T11:15:37.014Z",
        "dateReserved": "2022-11-30T06:54:13.183Z",
        "dateUpdated": "2026-05-29T14:08:13.754Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-79625 (GCVE-0-2026-79625)

    Vulnerability from cvelistv5 – Published: 2026-09-30 09:23 – Updated: 2026-09-30 13:49
    VLAI
    Title
    Improper Synchronization in Monitoring in CODESYS Control Runtime
    Summary
    Affected products do not properly synchronize access to their monitoring functionality. When multiple clients send concurrent requests, this may lead to incorrect reads or writes, or to corruption of internal memory structures. An authenticated remote attacker with monitoring access can exploit this issue to cause incorrect data processing or a denial-of-service condition.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-30 13:49 UTC
    CWE
    • CWE-362 - Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition')
    References
    Impacted products
    Vendor Product Version
    CODESYS Control RTE (SL) Affected: 3.0.0.0 , < 3.5.22.40 (semver)
    Create a notification for this product.
    CODESYS Control RTE (for Beckhoff CX) SL Affected: 3.0.0.0 , < 3.5.22.40 (semver)
    Create a notification for this product.
    CODESYS Control Win (SL) Affected: 3.0.0.0 , < 3.5.22.40 (semver)
    Create a notification for this product.
    CODESYS Runtime Toolkit Affected: 3.0.0.0 , < 3.5.22.40 (semver)
    Create a notification for this product.
    CODESYS Safety SIL2 Affected: 3.0.0.0 , < 3.5.22.40 (semver)
    Create a notification for this product.
    CODESYS HMI (SL) Affected: 3.0.0.0 , < 3.5.22.40 (semver)
    Create a notification for this product.
    CODESYS Development System 3 Affected: 3.0.0.0 , < 3.5.22.40 (semver)
    Create a notification for this product.
    CODESYS Control for BeagleBone SL Affected: 3.5.0.0 , < 4.23.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for emPC-A/iMX6 SL Affected: 3.5.0.0 , < 4.23.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for IOT2000 SL Affected: 3.5.0.0 , < 4.23.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for Linux ARM SL Affected: 3.5.0.0 , < 4.23.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for Linux SL Affected: 3.5.0.0 , < 4.23.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for PFC100 SL Affected: 3.5.0.0 , < 4.23.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for PFC200 SL Affected: 3.5.0.0 , < 4.23.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for PLCnext SL Affected: 3.5.0.0 , < 4.23.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for Raspberry Pi SL Affected: 3.5.0.0 , < 4.23.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for WAGO Touch Panels 600 SL Affected: 3.5.0.0 , < 4.23.0.0 (semver)
    Create a notification for this product.
    CODESYS Virtual Control SL Affected: 3.5.0.0 , < 4.23.0.0 (semver)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-79625",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-30T13:49:04.420443Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-30T13:49:14.992Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Control RTE (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.22.40",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control RTE (for Beckhoff CX) SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.22.40",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control Win (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.22.40",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Runtime Toolkit",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.22.40",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Safety SIL2",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.22.40",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "HMI (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.22.40",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Development System 3",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.22.40",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for BeagleBone SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.23.0.0",
                  "status": "affected",
                  "version": "3.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for emPC-A/iMX6 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.23.0.0",
                  "status": "affected",
                  "version": "3.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for IOT2000 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.23.0.0",
                  "status": "affected",
                  "version": "3.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Linux ARM SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.23.0.0",
                  "status": "affected",
                  "version": "3.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Linux SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.23.0.0",
                  "status": "affected",
                  "version": "3.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PFC100 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.23.0.0",
                  "status": "affected",
                  "version": "3.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PFC200 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.23.0.0",
                  "status": "affected",
                  "version": "3.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PLCnext SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.23.0.0",
                  "status": "affected",
                  "version": "3.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Raspberry Pi SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.23.0.0",
                  "status": "affected",
                  "version": "3.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for WAGO Touch Panels 600 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.23.0.0",
                  "status": "affected",
                  "version": "3.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Virtual Control SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.23.0.0",
                  "status": "affected",
                  "version": "3.5.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eAffected products do not properly synchronize access to their monitoring functionality. When multiple clients send concurrent requests, this may lead to incorrect reads or writes, or to corruption of internal memory structures. An authenticated remote attacker with monitoring access can exploit this issue to cause incorrect data processing or a denial-of-service condition.\u003c/p\u003e"
                }
              ],
              "value": "Affected products do not properly synchronize access to their monitoring functionality. When multiple clients send concurrent requests, this may lead to incorrect reads or writes, or to corruption of internal memory structures. An authenticated remote attacker with monitoring access can exploit this issue to cause incorrect data processing or a denial-of-service condition."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-362",
                  "description": "CWE-362 Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-30T09:23:16.775Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-097/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-097",
            "defect": [
              "CERT@VDE#642221"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Improper Synchronization in Monitoring in CODESYS Control Runtime",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-79625",
        "datePublished": "2026-09-30T09:23:16.775Z",
        "dateReserved": "2026-08-25T08:46:38.207Z",
        "dateUpdated": "2026-09-30T13:49:14.992Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41691 (GCVE-0-2025-41691)

    Vulnerability from cvelistv5 – Published: 2025-08-04 08:04 – Updated: 2025-08-04 16:32
    VLAI
    Title
    CODESYS Control DoS via Unauthenticated NULL Pointer Dereference
    Summary
    An unauthenticated remote attacker may trigger a NULL pointer dereference in the affected CODESYS Control runtime systems by sending specially crafted communication requests, potentially leading to a denial-of-service (DoS) condition.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-08-04 16:28 UTC
    CWE
    • CWE-476 - NULL Pointer Dereference
    References
    Impacted products
    Vendor Product Version
    CODESYS Control RTE (SL) Affected: 3.5.21.10 , < 3.5.21.20 (semver)
    Create a notification for this product.
    CODESYS Control RTE (for Beckhoff CX) SL Affected: 3.5.21.10 , < 3.5.21.20 (semver)
    Create a notification for this product.
    CODESYS Control Win (SL) Affected: 3.5.21.10 , < 3.5.21.20 (semver)
    Create a notification for this product.
    CODESYS HMI (SL) Affected: 3.5.21.10 , < 3.5.21.20 (semver)
    Create a notification for this product.
    CODESYS Control for BeagleBone SL Affected: 4.16.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for emPC-A/iMX6 SL Affected: 4.16.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for IOT2000 SL Affected: 4.16.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for Linux ARM SL Affected: 4.16.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for Linux SL Affected: 4.16.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for PFC100 SL Affected: 4.16.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for PFC200 SL Affected: 4.16.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for PLCnext SL Affected: 4.16.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for Raspberry Pi SL Affected: 4.16.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for WAGO Touch Panels 600 SL Affected: 4.16.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Virtual Control SL Affected: 4.16.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41691",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-08-04T16:28:09.392670Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-04T16:32:30.773Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Control RTE (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.20",
                  "status": "affected",
                  "version": "3.5.21.10",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control RTE (for Beckhoff CX) SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.20",
                  "status": "affected",
                  "version": "3.5.21.10",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control Win (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.20",
                  "status": "affected",
                  "version": "3.5.21.10",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "HMI (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.20",
                  "status": "affected",
                  "version": "3.5.21.10",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for BeagleBone SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "4.16.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for emPC-A/iMX6 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "4.16.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for IOT2000 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "4.16.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Linux ARM SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "4.16.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Linux SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "4.16.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PFC100 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "4.16.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PFC200 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "4.16.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PLCnext SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "4.16.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Raspberry Pi SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "4.16.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for WAGO Touch Panels 600 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "4.16.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Virtual Control SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "4.16.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An unauthenticated remote attacker may trigger a NULL pointer dereference in the affected CODESYS Control runtime systems by sending specially crafted communication requests, potentially leading to a denial-of-service (DoS) condition.\u003cbr\u003e"
                }
              ],
              "value": "An unauthenticated remote attacker may trigger a NULL pointer dereference in the affected CODESYS Control runtime systems by sending specially crafted communication requests, potentially leading to a denial-of-service (DoS) condition."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-476",
                  "description": "CWE-476 NULL Pointer Dereference",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-04T08:04:34.981Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/de/advisories/VDE-2025-070"
            }
          ],
          "source": {
            "advisory": "VDE-2025-070",
            "defect": [
              "CERT@VDE#641834"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "CODESYS Control DoS via Unauthenticated NULL Pointer Dereference",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-41691",
        "datePublished": "2025-08-04T08:04:34.981Z",
        "dateReserved": "2025-04-16T11:17:48.309Z",
        "dateUpdated": "2025-08-04T16:32:30.773Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-41659 (GCVE-0-2025-41659)

    Vulnerability from cvelistv5 – Published: 2025-08-04 08:04 – Updated: 2025-08-04 16:35
    VLAI
    Title
    CODESYS Control PKI Exposure Enables Remote Certificate Access
    Summary
    A low-privileged attacker can remotely access the PKI folder of the CODESYS Control runtime system and thus read and write certificates and its keys. This allows sensitive data to be extracted or to accept certificates as trusted. Although all services remain available, only unencrypted communication is possible if the certificates are deleted.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-08-04 16:34 UTC
    CWE
    • CWE-732 - Incorrect Permission Assignment for Critical Resource
    References
    Impacted products
    Vendor Product Version
    CODESYS Control RTE (SL) Affected: 0.0.0.0 , < 3.5.21.20 (semver)
    Create a notification for this product.
    CODESYS Control RTE (for Beckhoff CX) SL Affected: 0.0.0.0 , < 3.5.21.20 (semver)
    Create a notification for this product.
    CODESYS Control Win (SL) Affected: 0.0.0.0 , < 3.5.21.20 (semver)
    Create a notification for this product.
    CODESYS HMI (SL) Affected: 0.0.0.0 , < 3.5.21.20 (semver)
    Create a notification for this product.
    CODESYS Runtime Toolkit Affected: 0.0.0.0 , < 3.5.21.20 (semver)
    Create a notification for this product.
    CODESYS Control for BeagleBone SL Affected: 0.0.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for emPC-A/iMX6 SL Affected: 0.0.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for IOT2000 SL Affected: 0.0.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for Linux ARM SL Affected: 0.0.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for Linux SL Affected: 0.0.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for PFC100 SL Affected: 0.0.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for PFC200 SL Affected: 0.0.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for PLCnext SL Affected: 0.0.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for Raspberry Pi SL Affected: 0.0.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Control for WAGO Touch Panels 600 SL Affected: 0.0.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    CODESYS Virtual Control SL Affected: 0.0.0.0 , < 4.17.0.0 (semver)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41659",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-08-04T16:34:47.316036Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-04T16:35:32.484Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Control RTE (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.20",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control RTE (for Beckhoff CX) SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.20",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control Win (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.20",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "HMI (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.20",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Runtime Toolkit",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.20",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for BeagleBone SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for emPC-A/iMX6 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for IOT2000 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Linux ARM SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Linux SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PFC100 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PFC200 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PLCnext SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Raspberry Pi SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for WAGO Touch Panels 600 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Virtual Control SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.17.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Luca Borzacchiello from Nozomi Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A low-privileged attacker can remotely access the PKI folder of the CODESYS Control runtime system and thus read and write certificates and its keys. This allows sensitive data to be extracted or to accept certificates as trusted. Although all services remain available, only unencrypted communication is possible if the certificates are deleted.\u003cbr\u003e"
                }
              ],
              "value": "A low-privileged attacker can remotely access the PKI folder of the CODESYS Control runtime system and thus read and write certificates and its keys. This allows sensitive data to be extracted or to accept certificates as trusted. Although all services remain available, only unencrypted communication is possible if the certificates are deleted."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-732",
                  "description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-04T08:04:04.597Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/de/advisories/VDE-2025-051"
            }
          ],
          "source": {
            "advisory": "VDE-2025-051",
            "defect": [
              "CERT@VDE#641801"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "CODESYS Control PKI Exposure Enables Remote Certificate Access",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-41659",
        "datePublished": "2025-08-04T08:04:04.597Z",
        "dateReserved": "2025-04-16T11:17:48.307Z",
        "dateUpdated": "2025-08-04T16:35:32.484Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-41658 (GCVE-0-2025-41658)

    Vulnerability from cvelistv5 – Published: 2025-08-04 08:03 – Updated: 2025-08-04 11:52
    VLAI
    Title
    CODESYS Toolkit Exposes Sensitive Files via Default Permissions
    Summary
    CODESYS Runtime Toolkit-based products may expose sensitive files to local low-privileged operating system users due to default file permissions.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-08-04 11:52 UTC
    CWE
    • CWE-276 - Incorrect Default Permissions
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41658",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-08-04T11:52:31.347383Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-04T11:52:37.949Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Runtime Toolkit",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.20",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for BeagleBone SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.16.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for emPC-A/iMX6 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.16.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for IOT2000 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.16.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Linux ARM SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.16.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Linux SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.16.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PFC100 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.16.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PFC200 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.16.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PLCnext SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.16.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Raspberry Pi SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.16.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for WAGO Touch Panels 600 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.16.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Virtual Control SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.16.0.0",
                  "status": "affected",
                  "version": "0.0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Luca Borzacchiello from Nozomi Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "CODESYS Runtime Toolkit-based products may expose sensitive files to local low-privileged operating system users due to default file permissions.\u003cbr\u003e"
                }
              ],
              "value": "CODESYS Runtime Toolkit-based products may expose sensitive files to local low-privileged operating system users due to default file permissions."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-276",
                  "description": "CWE-276 Incorrect Default Permissions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-04T08:03:26.511Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/de/advisories/VDE-2025-049"
            }
          ],
          "source": {
            "advisory": "VDE-2025-049",
            "defect": [
              "CERT@VDE#641799"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "CODESYS Toolkit Exposes Sensitive Files via Default Permissions",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-41658",
        "datePublished": "2025-08-04T08:03:26.511Z",
        "dateReserved": "2025-04-16T11:17:48.306Z",
        "dateUpdated": "2025-08-04T11:52:37.949Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-4224 (GCVE-0-2022-4224)

    Vulnerability from cvelistv5 – Published: 2023-03-23 11:15 – Updated: 2026-05-29 14:08
    VLAI
    Title
    CODESYS: Exposure of Resource to Wrong Sphere in CODESYS V3
    Summary
    In multiple products of CODESYS v3 in multiple versions a remote low privileged user could utilize this vulnerability to read and modify system files and OS resources or DoS the device.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-05-29 14:07 UTC
    CWE
    • CWE-1188 - Insecure Default Initialization of Resource
    Impacted products
    Vendor Product Version
    CODESYS Control RTE (SL) Affected: 3.0.0.0 , < 3.5.19.0 (custom)
    Create a notification for this product.
    CODESYS Control RTE (for Beckhoff CX) SL Affected: 3.0.0.0 , < 3.5.19.0 (custom)
    Create a notification for this product.
    CODESYS Control Win (SL) Affected: 3.0.0.0 , < 3.5.19.0 (custom)
    Create a notification for this product.
    CODESYS Runtime Toolkit Affected: 3.0.0.0 , < 3.5.19.0 (custom)
    Create a notification for this product.
    CODESYS Safety SIL2 Runtime Toolkit Affected: 3.0.0.0 , < 3.5.19.0 (custom)
    Create a notification for this product.
    CODESYS Safety SIL2 PSP Affected: 3.0.0.0 , < 3.5.19.0 (custom)
    Create a notification for this product.
    CODESYS HMI (SL) Affected: 3.0.0.0 , < 3.5.19.0 (custom)
    Create a notification for this product.
    CODESYS Development System V3 Affected: 3.0.0.0 , < 3.5.19.0 (custom)
    Create a notification for this product.
    CODESYS Control for BeagleBone SL Affected: 3.0.0.0 , < 4.8.0.0 (custom)
    Create a notification for this product.
    CODESYS Control for emPC-A/iMX6 SL Affected: 3.0.0.0 , < 4.8.0.0 (custom)
    Create a notification for this product.
    CODESYS Control for IOT2000 SL Affected: 3.0.0.0 , < 4.8.0.0 (custom)
    Create a notification for this product.
    CODESYS Control for Linux SL Affected: 3.0.0.0 , < 4.8.0.0 (custom)
    Create a notification for this product.
    CODESYS Control for PFC100 SL Affected: 3.0.0.0 , < 4.8.0.0 (custom)
    Create a notification for this product.
    CODESYS Control for PFC200 SL Affected: 3.0.0.0 , < 4.8.0.0 (custom)
    Create a notification for this product.
    CODESYS Control for PLCnext SL Affected: 3.0.0.0 , < 4.8.0.0 (custom)
    Create a notification for this product.
    CODESYS Control for Raspberry Pi SL Affected: 3.0.0.0 , < 4.8.0.0 (custom)
    Create a notification for this product.
    CODESYS Control for WAGO Touch Panels 600 SL Affected: 3.0.0.0 , < 4.8.0.0 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T01:34:49.591Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17553\u0026token=cf49757d232ea8021f0c0dd6c65e71ea5942b12d\u0026download="
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-4224",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T14:07:26.160566Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T14:08:13.754Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Control RTE (SL) ",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.19.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control RTE (for Beckhoff CX) SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.19.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control Win (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.19.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": " Runtime Toolkit ",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.19.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Safety SIL2 Runtime Toolkit",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.19.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Safety SIL2 PSP",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.19.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "HMI (SL) ",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.19.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Development System V3",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.19.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": " Control for BeagleBone SL ",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.8.0.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for emPC-A/iMX6 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.8.0.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for IOT2000 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.8.0.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Linux SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.8.0.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": " Control for PFC100 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.8.0.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": " Control for PFC200 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.8.0.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PLCnext SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.8.0.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Raspberry Pi SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.8.0.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for WAGO Touch Panels 600 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.8.0.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Franklin Zhao from ELEX FEIGONG RESEARCH INSTITUTE of Elex CyberSecurity"
            },
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Reid Wightman of Dragos"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "In multiple products of CODESYS v3 in multiple versions a remote low privileged user\u0026nbsp;could utilize this vulnerability to read and modify system files and OS resources or DoS the device."
                }
              ],
              "value": "In multiple products of CODESYS v3 in multiple versions a remote low privileged user\u00a0could utilize this vulnerability to read and modify system files and OS resources or DoS the device."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1188",
                  "description": "CWE-1188 Insecure Default Initialization of Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-09T10:47:13.144Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17553\u0026token=cf49757d232ea8021f0c0dd6c65e71ea5942b12d\u0026download="
            }
          ],
          "source": {
            "defect": [
              "CERT@VDE#64318"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "CODESYS:  Exposure of Resource to Wrong Sphere in CODESYS V3",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-4224",
        "datePublished": "2023-03-23T11:15:37.014Z",
        "dateReserved": "2022-11-30T06:54:13.183Z",
        "dateUpdated": "2026-05-29T14:08:13.754Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }