Search

Find a vulnerability

Search criteria

    6 vulnerabilities found for AC9 by Tenda

    CVE-2026-104611 (GCVE-0-2026-104611)

    Vulnerability from nvd – Published: 2026-10-02 12:15 – Updated: 2026-10-02 13:30
    VLAI
    Title
    Tenda AC9 POST Request fast_setting_internet_set stack-based overflow
    Summary
    A vulnerability was detected in Tenda AC9 15.03.02.13. Affected is an unknown function of the file /goform/fast_setting_internet_set of the component POST Request Handler. Performing a manipulation of the argument netWanType results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-02 13:30 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.02.13
        cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-104611",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-02T13:30:30.834838Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-02T13:30:49.550Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "POST Request Handler"
              ],
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.02.13"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "hodor (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was detected in Tenda AC9 15.03.02.13. Affected is an unknown function of the file /goform/fast_setting_internet_set of the component POST Request Handler. Performing a manipulation of the argument netWanType results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 8.3,
                "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-02T12:15:15.494Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-412918 | Tenda AC9 POST Request fast_setting_internet_set stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/412918"
            },
            {
              "name": "VDB-412918 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/412918/cti"
            },
            {
              "name": "CVE-2026-104611 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-104611"
            },
            {
              "name": "Submit #962720 | Tenda RouterOS AC9V1.0BR_V15.03.2.13 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/962720"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/ZaneBoden/CVEs/blob/main/Tenda-AC9-fast_setting_internet_set.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-02T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-02T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-02T05:56:56.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9 POST Request fast_setting_internet_set stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-104611",
        "datePublished": "2026-10-02T12:15:15.494Z",
        "dateReserved": "2026-10-02T03:51:51.618Z",
        "dateUpdated": "2026-10-02T13:30:49.550Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-86300 (GCVE-0-2026-86300)

    Vulnerability from nvd – Published: 2026-09-07 11:30 – Updated: 2026-09-08 15:03
    VLAI
    Title
    Tenda AC9 Web Management R7WebsSecurityHandler improper authentication
    Summary
    A flaw has been found in Tenda AC9 15.03.05.14. This impacts the function R7WebsSecurityHandler of the component Web Management. This manipulation causes improper authentication. The attack may be initiated remotely. The exploit has been published and may be used.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-08 15:03 UTC
    CWE
    • CWE-287 - Improper Authentication
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.05.14
        cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-86300",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-08T15:03:18.638512Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-08T15:03:32.769Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/limou89/somevul/blob/main/Tenda_AC9_getProduct_Info_Disclosure.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management"
              ],
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.05.14"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "sleep (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in Tenda AC9 15.03.05.14. This impacts the function R7WebsSecurityHandler of the component Web Management. This manipulation causes improper authentication. The attack may be initiated remotely. The exploit has been published and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 7.5,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-07T11:30:09.363Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-399464 | Tenda AC9 Web Management R7WebsSecurityHandler improper authentication",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/399464"
            },
            {
              "name": "VDB-399464 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/399464/cti"
            },
            {
              "name": "CVE-2026-86300 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-86300"
            },
            {
              "name": "Submit #906606 | Tenda AC9 V15.03.05.14 Information Disclosure",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/906606"
            },
            {
              "name": "Submit #906607 | Tenda AC9 V15.03.05.14_multi / V15.03.05.16_multi Improper Access Controls (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/906607"
            },
            {
              "name": "Submit #906608 | Tenda AC9 V15.03.05.14_multi / V15.03.05.16_multi Improper Access Controls (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/906608"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/limou89/somevul/blob/main/Tenda_AC9_getProduct_Info_Disclosure.md"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/limou89/somevul/blob/main/Tenda_AC9_fast_setting_wifi_set_Unauth_Password.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-09-06T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-09-06T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-09-06T18:38:25.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9 Web Management R7WebsSecurityHandler improper authentication",
          "x_generator": [
            "VulDB PVTS v202609"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-86300",
        "datePublished": "2026-09-07T11:30:09.363Z",
        "dateReserved": "2026-09-06T16:33:21.215Z",
        "dateUpdated": "2026-09-08T15:03:32.769Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-14286 (GCVE-0-2025-14286)

    Vulnerability from nvd – Published: 2025-12-09 01:32 – Updated: 2026-02-24 05:45
    VLAI
    Title
    Tenda AC9 Configuration File DownloadCfg.jpg information disclosure
    Summary
    A vulnerability was determined in Tenda AC9 15.03.05.14_multi. Affected by this vulnerability is an unknown functionality of the file /cgi-bin/DownloadCfg.jpg of the component Configuration File Handler. This manipulation causes information disclosure. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-12-09 14:35 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/?id.334874 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.334874 signaturepermissions-required
    https://vuldb.com/?submit.702723 third-party-advisory
    https://github.com/Madgeaaaaa/MY_VULN_2/blob/main… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.05.14_multi
        cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-14286",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-09T14:35:32.257434Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-09T16:03:13.496Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN11.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Configuration File Handler"
              ],
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.05.14_multi"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "jiahui2888 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda AC9 15.03.05.14_multi. Affected by this vulnerability is an unknown functionality of the file /cgi-bin/DownloadCfg.jpg of the component Configuration File Handler. This manipulation causes information disclosure. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:W/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:W/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 5,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N/E:POC/RL:W/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "Information Disclosure",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "Improper Access Controls",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-24T05:45:24.166Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-334874 | Tenda AC9 Configuration File DownloadCfg.jpg information disclosure",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.334874"
            },
            {
              "name": "VDB-334874 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.334874"
            },
            {
              "name": "Submit #702723 | Tenda AC9 V1.0  V15.03.05.14_multi Information Disclosure",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.702723"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN11.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-12-08T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-12-08T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-12-12T08:32:52.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9 Configuration File DownloadCfg.jpg information disclosure"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-14286",
        "datePublished": "2025-12-09T01:32:07.198Z",
        "dateReserved": "2025-12-08T18:49:39.958Z",
        "dateUpdated": "2026-02-24T05:45:24.166Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-104611 (GCVE-0-2026-104611)

    Vulnerability from cvelistv5 – Published: 2026-10-02 12:15 – Updated: 2026-10-02 13:30
    VLAI
    Title
    Tenda AC9 POST Request fast_setting_internet_set stack-based overflow
    Summary
    A vulnerability was detected in Tenda AC9 15.03.02.13. Affected is an unknown function of the file /goform/fast_setting_internet_set of the component POST Request Handler. Performing a manipulation of the argument netWanType results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-02 13:30 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.02.13
        cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-104611",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-02T13:30:30.834838Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-02T13:30:49.550Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "POST Request Handler"
              ],
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.02.13"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "hodor (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was detected in Tenda AC9 15.03.02.13. Affected is an unknown function of the file /goform/fast_setting_internet_set of the component POST Request Handler. Performing a manipulation of the argument netWanType results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 8.3,
                "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-02T12:15:15.494Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-412918 | Tenda AC9 POST Request fast_setting_internet_set stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/412918"
            },
            {
              "name": "VDB-412918 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/412918/cti"
            },
            {
              "name": "CVE-2026-104611 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-104611"
            },
            {
              "name": "Submit #962720 | Tenda RouterOS AC9V1.0BR_V15.03.2.13 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/962720"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/ZaneBoden/CVEs/blob/main/Tenda-AC9-fast_setting_internet_set.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-02T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-02T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-02T05:56:56.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9 POST Request fast_setting_internet_set stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-104611",
        "datePublished": "2026-10-02T12:15:15.494Z",
        "dateReserved": "2026-10-02T03:51:51.618Z",
        "dateUpdated": "2026-10-02T13:30:49.550Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-86300 (GCVE-0-2026-86300)

    Vulnerability from cvelistv5 – Published: 2026-09-07 11:30 – Updated: 2026-09-08 15:03
    VLAI
    Title
    Tenda AC9 Web Management R7WebsSecurityHandler improper authentication
    Summary
    A flaw has been found in Tenda AC9 15.03.05.14. This impacts the function R7WebsSecurityHandler of the component Web Management. This manipulation causes improper authentication. The attack may be initiated remotely. The exploit has been published and may be used.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-08 15:03 UTC
    CWE
    • CWE-287 - Improper Authentication
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.05.14
        cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-86300",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-08T15:03:18.638512Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-08T15:03:32.769Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/limou89/somevul/blob/main/Tenda_AC9_getProduct_Info_Disclosure.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management"
              ],
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.05.14"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "sleep (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in Tenda AC9 15.03.05.14. This impacts the function R7WebsSecurityHandler of the component Web Management. This manipulation causes improper authentication. The attack may be initiated remotely. The exploit has been published and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 7.5,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-07T11:30:09.363Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-399464 | Tenda AC9 Web Management R7WebsSecurityHandler improper authentication",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/399464"
            },
            {
              "name": "VDB-399464 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/399464/cti"
            },
            {
              "name": "CVE-2026-86300 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-86300"
            },
            {
              "name": "Submit #906606 | Tenda AC9 V15.03.05.14 Information Disclosure",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/906606"
            },
            {
              "name": "Submit #906607 | Tenda AC9 V15.03.05.14_multi / V15.03.05.16_multi Improper Access Controls (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/906607"
            },
            {
              "name": "Submit #906608 | Tenda AC9 V15.03.05.14_multi / V15.03.05.16_multi Improper Access Controls (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/906608"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/limou89/somevul/blob/main/Tenda_AC9_getProduct_Info_Disclosure.md"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/limou89/somevul/blob/main/Tenda_AC9_fast_setting_wifi_set_Unauth_Password.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-09-06T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-09-06T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-09-06T18:38:25.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9 Web Management R7WebsSecurityHandler improper authentication",
          "x_generator": [
            "VulDB PVTS v202609"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-86300",
        "datePublished": "2026-09-07T11:30:09.363Z",
        "dateReserved": "2026-09-06T16:33:21.215Z",
        "dateUpdated": "2026-09-08T15:03:32.769Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-14286 (GCVE-0-2025-14286)

    Vulnerability from cvelistv5 – Published: 2025-12-09 01:32 – Updated: 2026-02-24 05:45
    VLAI
    Title
    Tenda AC9 Configuration File DownloadCfg.jpg information disclosure
    Summary
    A vulnerability was determined in Tenda AC9 15.03.05.14_multi. Affected by this vulnerability is an unknown functionality of the file /cgi-bin/DownloadCfg.jpg of the component Configuration File Handler. This manipulation causes information disclosure. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-12-09 14:35 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/?id.334874 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.334874 signaturepermissions-required
    https://vuldb.com/?submit.702723 third-party-advisory
    https://github.com/Madgeaaaaa/MY_VULN_2/blob/main… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.05.14_multi
        cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-14286",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-09T14:35:32.257434Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-09T16:03:13.496Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN11.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Configuration File Handler"
              ],
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.05.14_multi"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "jiahui2888 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda AC9 15.03.05.14_multi. Affected by this vulnerability is an unknown functionality of the file /cgi-bin/DownloadCfg.jpg of the component Configuration File Handler. This manipulation causes information disclosure. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:W/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:W/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 5,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N/E:POC/RL:W/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "Information Disclosure",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "Improper Access Controls",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-24T05:45:24.166Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-334874 | Tenda AC9 Configuration File DownloadCfg.jpg information disclosure",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.334874"
            },
            {
              "name": "VDB-334874 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.334874"
            },
            {
              "name": "Submit #702723 | Tenda AC9 V1.0  V15.03.05.14_multi Information Disclosure",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.702723"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN11.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-12-08T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-12-08T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-12-12T08:32:52.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9 Configuration File DownloadCfg.jpg information disclosure"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-14286",
        "datePublished": "2025-12-09T01:32:07.198Z",
        "dateReserved": "2025-12-08T18:49:39.958Z",
        "dateUpdated": "2026-02-24T05:45:24.166Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }