    CVE-2026-123966 (GCVE-0-2026-123966)

    Vulnerability from nvd – Published: 2026-11-07 13:45 – Updated: 2026-11-09 22:41
    VLAI
    Title
    Tenda AC19 saveParentControlInfo heap-based overflow
    Summary
    A vulnerability was determined in Tenda AC19 16.03.10.07. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. This manipulation of the argument deviceId causes heap-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-09 22:40 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda AC19 Affected: 16.03.10.07
        cpe:2.3:h:tenda:ac19:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-123966",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-09T22:40:09.150272Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-09T22:41:45.932Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:ac19:*:*:*:*:*:*:*:*"
              ],
              "product": "AC19",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.10.07"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "tmzhou (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda AC19 16.03.10.07. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. This manipulation of the argument deviceId causes heap-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:C",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:C",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-07T13:45:19.423Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-432038 | Tenda AC19 saveParentControlInfo heap-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/432038"
            },
            {
              "name": "VDB-432038 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/432038/cti"
            },
            {
              "name": "CVE-2026-123966 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-123966"
            },
            {
              "name": "Submit #1035173 | Tenda AC19 V16.03.10.07 Heap-Based Buffer Overflow (CWE-122)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1035173"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Tmzop/Tenda-AC19-saveParentControlInfo/blob/main/report.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-06T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-06T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-06T18:21:28.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC19 saveParentControlInfo heap-based overflow",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-123966",
        "datePublished": "2026-11-07T13:45:19.423Z",
        "dateReserved": "2026-11-06T17:16:21.436Z",
        "dateUpdated": "2026-11-09T22:41:45.932Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-113744 (GCVE-0-2026-113744)

    Vulnerability from nvd – Published: 2026-10-21 01:30 – Updated: 2026-10-28 16:21
    VLAI
    Title
    Tenda AC19 httpd Web Management Service SetFirewallCfg formSetFirewallCfg stack-based overflow
    Summary
    A security vulnerability has been detected in Tenda AC19 16.03.10.07. The impacted element is the function formSetFirewallCfg of the file /goform/SetFirewallCfg of the component httpd Web Management Service. Such manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed publicly and may be used.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-28 16:20 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/vuln/422925 vdb-entrytechnical-description
    https://vuldb.com/vuln/422925/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-113744 third-party-advisory
    https://vuldb.com/submit/1018542 third-party-advisory
    https://github.com/henrythekingofuk/TendaCVE exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC19 Affected: 16.03.10.07
        cpe:2.3:h:tenda:ac19:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-113744",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-28T16:20:49.387664Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-28T16:21:28.084Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:ac19:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "httpd Web Management Service"
              ],
              "product": "AC19",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.10.07"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Zeming Hu (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security vulnerability has been detected in Tenda AC19 16.03.10.07. The impacted element is the function formSetFirewallCfg of the file /goform/SetFirewallCfg of the component httpd Web Management Service. Such manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed publicly and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-21T01:30:24.075Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-422925 | Tenda AC19 httpd Web Management Service SetFirewallCfg formSetFirewallCfg stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/422925"
            },
            {
              "name": "VDB-422925 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/422925/cti"
            },
            {
              "name": "CVE-2026-113744 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-113744"
            },
            {
              "name": "Submit #1018542 | Tenda AC19 V16.03.10.07 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1018542"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/henrythekingofuk/TendaCVE"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-20T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-20T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-20T18:58:39.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC19 httpd Web Management Service SetFirewallCfg formSetFirewallCfg stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-113744",
        "datePublished": "2026-10-21T01:30:24.075Z",
        "dateReserved": "2026-10-20T16:53:34.154Z",
        "dateUpdated": "2026-10-28T16:21:28.084Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-123966 (GCVE-0-2026-123966)

    Vulnerability from cvelistv5 – Published: 2026-11-07 13:45 – Updated: 2026-11-09 22:41
    VLAI
    Title
    Tenda AC19 saveParentControlInfo heap-based overflow
    Summary
    A vulnerability was determined in Tenda AC19 16.03.10.07. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. This manipulation of the argument deviceId causes heap-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-09 22:40 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda AC19 Affected: 16.03.10.07
        cpe:2.3:h:tenda:ac19:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-123966",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-09T22:40:09.150272Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-09T22:41:45.932Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:ac19:*:*:*:*:*:*:*:*"
              ],
              "product": "AC19",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.10.07"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "tmzhou (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda AC19 16.03.10.07. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. This manipulation of the argument deviceId causes heap-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:C",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:C",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-07T13:45:19.423Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-432038 | Tenda AC19 saveParentControlInfo heap-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/432038"
            },
            {
              "name": "VDB-432038 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/432038/cti"
            },
            {
              "name": "CVE-2026-123966 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-123966"
            },
            {
              "name": "Submit #1035173 | Tenda AC19 V16.03.10.07 Heap-Based Buffer Overflow (CWE-122)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1035173"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Tmzop/Tenda-AC19-saveParentControlInfo/blob/main/report.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-06T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-06T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-06T18:21:28.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC19 saveParentControlInfo heap-based overflow",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-123966",
        "datePublished": "2026-11-07T13:45:19.423Z",
        "dateReserved": "2026-11-06T17:16:21.436Z",
        "dateUpdated": "2026-11-09T22:41:45.932Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-113744 (GCVE-0-2026-113744)

    Vulnerability from cvelistv5 – Published: 2026-10-21 01:30 – Updated: 2026-10-28 16:21
    VLAI
    Title
    Tenda AC19 httpd Web Management Service SetFirewallCfg formSetFirewallCfg stack-based overflow
    Summary
    A security vulnerability has been detected in Tenda AC19 16.03.10.07. The impacted element is the function formSetFirewallCfg of the file /goform/SetFirewallCfg of the component httpd Web Management Service. Such manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed publicly and may be used.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-28 16:20 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/vuln/422925 vdb-entrytechnical-description
    https://vuldb.com/vuln/422925/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-113744 third-party-advisory
    https://vuldb.com/submit/1018542 third-party-advisory
    https://github.com/henrythekingofuk/TendaCVE exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC19 Affected: 16.03.10.07
        cpe:2.3:h:tenda:ac19:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-113744",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-28T16:20:49.387664Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-28T16:21:28.084Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:ac19:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "httpd Web Management Service"
              ],
              "product": "AC19",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.10.07"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Zeming Hu (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security vulnerability has been detected in Tenda AC19 16.03.10.07. The impacted element is the function formSetFirewallCfg of the file /goform/SetFirewallCfg of the component httpd Web Management Service. Such manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed publicly and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-21T01:30:24.075Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-422925 | Tenda AC19 httpd Web Management Service SetFirewallCfg formSetFirewallCfg stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/422925"
            },
            {
              "name": "VDB-422925 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/422925/cti"
            },
            {
              "name": "CVE-2026-113744 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-113744"
            },
            {
              "name": "Submit #1018542 | Tenda AC19 V16.03.10.07 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1018542"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/henrythekingofuk/TendaCVE"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-20T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-20T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-20T18:58:39.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC19 httpd Web Management Service SetFirewallCfg formSetFirewallCfg stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-113744",
        "datePublished": "2026-10-21T01:30:24.075Z",
        "dateReserved": "2026-10-20T16:53:34.154Z",
        "dateUpdated": "2026-10-28T16:21:28.084Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }