Visit Website →

Recent Items

SEVD-2026-251-04 — Incorrect Implementation of Authentication Algorithm vulnerability on Modicon M580 and Modicon M580 Safety

Schneider Electric is aware of a vulnerability in its Modicon M580 and Modicon M580 Safety controllers. The Modicon M580 is an Ethernet-based Programmable Automation Controller (ePAC) designed for industrial digital transformation. Failure to apply the remediations provided below may risk establishing an unauthenticated connection to Modicon M580 or M580 Safety controllers which could result in loss of confidentiality, integrity and availability of the PLC.

Published on Tue, 08 Sep 2026 07:00:00 +0000

SEVD-2026-251-03 — Insufficiently Protected Credentials vulnerability on SCADAPack x70 Products

Schneider Electric is aware of a vulnerability in its SCADAPack x70 products. The SCADAPack 47x, SCADAPack 47xi, SCADAPack 47xd, SCADAPack 470R and SCADAPack 57x products are Remote Terminal Units that provide communication capabilities for remote monitoring and control. Failure to apply the mitigations provided below may increase the risk of unauthorized access to RTU configuration through the Secure Lock functionality, potentially resulting in a loss of confidentiality.

Published on Tue, 08 Sep 2026 07:00:00 +0000

SEVD-2026-251-02 — Improper Neutralization of Special Elements used in an OS Command vulnerability on PowerLogic T300

Schneider Electric is aware of a vulnerability in the Head Unit (HU250) for the PowerLogic T300 RTU (Remote Terminal Unit) (formerly Easergy T300 RTU). The [PowerLogic T300 RTU](https://www.se.com/ww/en/product-range/62399-easergy-t300) is a modular platform for medium voltage and low voltage public distribution network management. Failure to apply the remediation provided below may risk privilege escalation, which could result in unauthorized takeover of the device.

Published on Tue, 08 Sep 2026 07:00:00 +0000

SEVD-2026-251-01 — Multiple Vulnerabilities on EcoStruxure IT Data Center Expert

Schneider Electric is aware of its vulnerability in its EcoStruxure IT Data Center Expert product The EcoStruxure IT Data Center Expert product is a scalable monitoring software that collects, organizes,and distributes critical device information providing a comprehensive view of equipment. Failure to apply the remediation provided below may risk information disclosure and remote compromise of the offer which could result in disruption of operations and access to system data.

Published on Tue, 08 Sep 2026 07:00:00 +0000

SEVD-2024-317-02 — Modicon Controllers M340 / Momentum / MC80 & EcoStruxure™ Control Expert

Schneider Electric is aware of multiple vulnerabilities in its Modicon Controllers M340 / Momentum / MC80 / EcoStruxure™ Control Expert products. [Modicon PAC](https://www.se.com/ww/en/product-subcategory/3950-pac-programmable-automation-controllers/?filter=business-1-industrial-automation-and-control) products control and monitor industrial operations. [EcoStruxure™ Control Expert](https://www.se.com/ww/en/product-range/548-ecostruxure-control-expert-unity-pro/#overview) is the engineering a…

Published on Tue, 12 Nov 2024 00:00:00 +0000

SEVD-2024-044-01 — EcoStruxure™ Control Expert, EcoStruxure™ Process Expert and Modicon M340, M580 and M580 Safety PLCs

Schneider Electric is aware of multiple vulnerabilities in its EcoStruxure™ Control Expert , EcoStruxure™ Process Expert and Modicon M340, M580 PLCs (Programmable Logic Controllers). Modicon PLCs control and monitor industrial operations. EcoStruxure™ Control Expert is the common programming, debugging and operating software for Modicon PLCs. EcoStruxure™ Process Expert DCS is a single automation system to engineer, operate, and maintain an entire plant Infrastructure. Failure to apply…

Published on Tue, 13 Feb 2024 12:41:43 +0000

SEVD-2023-010-06 — EcoStruxure™ Control Expert, EcoStruxure™ Process Expert and Modicon M340, M580 and M580 CPU Safety

Schneider Electric is aware of multiple vulnerabilities in its EcoStruxure™ Control Expert, Modicon M340, Momentum, MC80, M580 and M580 CPU Safety. The Modicon M580 are PAC and Safety PLCs with built-in Ethernet for process, high availability & safety solutions. The Modicon M340 offers compactness, flexibility, scalability, and robustness for the process industry and a wide range of demanding automation applications. The Modicon MC80 provides optimized operation, withstanding extreme cond…

Published on Tue, 10 Jan 2023 00:00:00 +0000

SEVD-2019-134-11 — Multiple Vulnerabilities in Modicon Controller Products

Schneider Electric is aware of multiple vulnerabilities in its Modicon Controller products. The [Modicon Programmable Automation controllers](https://www.se.com/ww/en/product-subcategory/3950-pac-programmable-automation-controllers/) are used for complex networked communication, display and control applications Failure to apply the mitigations or remediations provided below may risk execution of unsolicited command on the PLC which could result in a loss of availability of the contro…

Published on Tue, 14 May 2019 07:00:00 +0000

SEVD-2026-132-02 — Insufficient Entropy vulnerability on Multiple Products

Schneider Electric is aware of a vulnerability in the following products: The Easergy C5 is a scalable and interoperable bay controller, protection and merging unit for large and critical infrastructure electrical distribution systems. The Easergy MiCOM P30 is a family of multifunction protection and control relays designed for medium, high and extra high voltage electrical networks. The Easergy MiCOM P40 is a protection relay series for Medium Voltage, High Voltage and Extra High Volt…

Published on Tue, 12 May 2026 07:00:00 +0000

SEVD-2026-223-02 — Multiple Vulnerabilities on NetBotz 5 750/755 Products

Schneider Electric is aware of multiple vulnerabilities in its NetBotz 5 – 750/755 products.The NetBotz 5 – 750/755 products are security and environmental monitors providing temperature, humidity, leak, smoke, vibration, door contact, and video monitoring capabilities.Failure to apply the remediation provided below may risk arbitrary or remote code execution over the local network, which could result in device manipulation and unauthorized data access.

Published on Tue, 11 Aug 2026 07:00:00 +0000