      <title>CVE-2026-17583 — Thermo Fisher Applied Biosystems Genetic Analyzers Missing Support for Integrity Check</title>
      <link>https://cve.radiocsirt.org/vuln/cve-2026-17583</link>
      <description>&lt;p&gt;&lt;strong&gt;Affected:&lt;/strong&gt; Thermo Fisher Applied Biosystems 3500/3500xL Series Data Collection Software, Thermo Fisher Applied Biosystems 3730/3730xL Series Data Collection Software, Thermo Fisher Applied Biosystems SeqStudio Genetic Analyzer Data Collection Software, Thermo Fisher Applied Biosystems SeqStudio Flex Series Instrument Software, Thermo Fisher Applied Biosystems GeneMapper ID-X Software, Thermo Fisher Applied Biosystems 3130 Series Data Collection Software, Thermo Fisher ABI PRISM 3100/3100-Avant Data Collection Software, Thermo Fisher ABI PRISM 310 Data Collection Software&lt;/p&gt;
&lt;p&gt;The affected&lt;/p&gt;
&lt;p&gt;Thermo Fisher Applied Biosystems Genetic Analyzers are vulnerable because .fsa/.hid output files can be edited. An attacker could tamper with these files, altering DNA data and resulting in inaccurate DNA test outcomes.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;&lt;strong&gt;Affected:&lt;/strong&gt; Thermo Fisher Applied Biosystems 3500/3500xL Series Data Collection Software, Thermo Fisher Applied Biosystems 3730/3730xL Series Data Collection Software, Thermo Fisher Applied Biosystems SeqStudio Genetic Analyzer Data Collection Software, Thermo Fisher Applied Biosystems SeqStudio Flex Series Instrument Software, Thermo Fisher Applied Biosystems GeneMapper ID-X Software, Thermo Fisher Applied Biosystems 3130 Series Data Collection Software, Thermo Fisher ABI PRISM 3100/3100-Avant Data Collection Software, Thermo Fisher ABI PRISM 310 Data Collection Software&lt;/p&gt;
&lt;p&gt;The affected&lt;/p&gt;
&lt;p&gt;Thermo Fisher Applied Biosystems Genetic Analyzers are vulnerable because .fsa/.hid output files can be edited. An attacker could tamper with these files, altering DNA data and resulting in inaccurate DNA test outcomes.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/cve-2026-17583</guid>