      <title>CVE-2019-6538 — Medtronic Conexus Radio Frequency Telemetry Protocol Improper Access Control</title>
      <link>https://cve.radiocsirt.org/vuln/cve-2019-6538</link>
      <description>&lt;p&gt;&lt;strong&gt;Affected:&lt;/strong&gt; Medtronic Conexus Radio Frequency Telemetry Protocol, Medtronic MyCareLink Monitor, Medtronic CareLink Monitor, Medtronic CareLink 2090 Programmer, Medtronic Amplia CRT-D, Medtronic Claria CRT-D, Medtronic Compia CRT-D, Medtronic Concerto CRT-D, Medtronic Concerto II CRT-D, Medtronic Consulta CRT-D and 14 more&lt;/p&gt;
&lt;p&gt;The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product’s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;&lt;strong&gt;Affected:&lt;/strong&gt; Medtronic Conexus Radio Frequency Telemetry Protocol, Medtronic MyCareLink Monitor, Medtronic CareLink Monitor, Medtronic CareLink 2090 Programmer, Medtronic Amplia CRT-D, Medtronic Claria CRT-D, Medtronic Compia CRT-D, Medtronic Concerto CRT-D, Medtronic Concerto II CRT-D, Medtronic Consulta CRT-D and 14 more&lt;/p&gt;
&lt;p&gt;The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product’s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device.&lt;/p&gt;</content:encoded>