      <title>CVE-2022-1797 — Rockwell Automation Logix Controllers Uncontrolled Resource Consumption</title>
      <link>https://cve.radiocsirt.org/vuln/cve-2022-1797</link>
      <description>&lt;p&gt;&lt;strong&gt;Affected:&lt;/strong&gt; Rockwell Automation CompactLogix 5380 controllers, Rockwell Automation Compact GuardLogix 5380 controllers, Rockwell Automation CompactLogix 5480 controllers, Rockwell Automation ControlLogix 5580 controllers, Rockwell Automation GuardLogix 5580 controllers, Rockwell Automation CompactLogix 5370 controllers, Rockwell Automation Compact GuardLogix 5370 controllers, Rockwell Automation ControlLogix 5570 controllers, Rockwell Automation GuardLogix 5570 controllers&lt;/p&gt;
&lt;p&gt;A malformed Class 3 common industrial protocol message with a cached connection can cause a denial-of-service condition in Rockwell Automation Logix Controllers, resulting in a major nonrecoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload the user project file to bring the device back online.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;&lt;strong&gt;Affected:&lt;/strong&gt; Rockwell Automation CompactLogix 5380 controllers, Rockwell Automation Compact GuardLogix 5380 controllers, Rockwell Automation CompactLogix 5480 controllers, Rockwell Automation ControlLogix 5580 controllers, Rockwell Automation GuardLogix 5580 controllers, Rockwell Automation CompactLogix 5370 controllers, Rockwell Automation Compact GuardLogix 5370 controllers, Rockwell Automation ControlLogix 5570 controllers, Rockwell Automation GuardLogix 5570 controllers&lt;/p&gt;
&lt;p&gt;A malformed Class 3 common industrial protocol message with a cached connection can cause a denial-of-service condition in Rockwell Automation Logix Controllers, resulting in a major nonrecoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload the user project file to bring the device back online.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/cve-2022-1797</guid>