<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Wed, 07 Oct 2026 19:57:55 +0000</lastBuildDate>
    <item>
      <title>CVE-2023-22411 — Junos OS: SRX Series: The flow processing daemon (flowd) will crash when Unified Policies are used with IPv6 and certai…</title>
      <link>https://cve.radiocsirt.org/vuln/cve-2023-22411</link>
      <description>&lt;p&gt;&lt;strong&gt;Affected:&lt;/strong&gt; Juniper Networks Junos OS&lt;/p&gt;
&lt;p&gt;An Out-of-Bounds Write vulnerability in Flow Processing Daemon (flowd) of Juniper Networks Junos OS allows an unauthenticated, network-based attacker to cause Denial of Service (DoS). On SRX Series devices using Unified Policies with IPv6, when a specific IPv6 packet goes through a dynamic-application filter which will generate an ICMP deny message, the flowd core is observed and the PFE is restarted. This issue affects: Juniper Networks Junos OS on SRX Series: 19.2 versions prior to 19.2R3-S6; 19.3 versions prior to 19.3R3-S6; 19.4 versions prior to 19.4R3-S9; 20.2 versions prior to 20.2R3-S5; 20.3 versions prior to 20.3R3-S4; 20.4 versions prior to 20.4R3-S3; 21.1 versions prior to 21.1R3; 21.2 versions prior to 21.2R3; 21.3 versions prior to 21.3R2; 21.4 versions prior to 21.4R2.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;&lt;strong&gt;Affected:&lt;/strong&gt; Juniper Networks Junos OS&lt;/p&gt;
&lt;p&gt;An Out-of-Bounds Write vulnerability in Flow Processing Daemon (flowd) of Juniper Networks Junos OS allows an unauthenticated, network-based attacker to cause Denial of Service (DoS). On SRX Series devices using Unified Policies with IPv6, when a specific IPv6 packet goes through a dynamic-application filter which will generate an ICMP deny message, the flowd core is observed and the PFE is restarted. This issue affects: Juniper Networks Junos OS on SRX Series: 19.2 versions prior to 19.2R3-S6; 19.3 versions prior to 19.3R3-S6; 19.4 versions prior to 19.4R3-S9; 20.2 versions prior to 20.2R3-S5; 20.3 versions prior to 20.3R3-S4; 20.4 versions prior to 20.4R3-S3; 21.1 versions prior to 21.1R3; 21.2 versions prior to 21.2R3; 21.3 versions prior to 21.3R2; 21.4 versions prior to 21.4R2.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/cve-2023-22411</guid>
    </item>
  </channel>
</rss>
