      <title>CVE-2019-6540 — Medtronic Conexus Radio Frequency Telemetry Protocol Cleartext Transmission of Sensitive Information</title>
      <link>https://cve.radiocsirt.org/vuln/cve-2019-6540</link>
      <description>&lt;p&gt;&lt;strong&gt;Affected:&lt;/strong&gt; Medtronic Conexus Radio Frequency Telemetry Protocol, Medtronic MyCareLink Monitor, Medtronic CareLink Monitor, Medtronic CareLink 2090 Programmer, Medtronic Amplia CRT-D, Medtronic Claria CRT-D, Medtronic Compia CRT-D, Medtronic Concerto CRT-D, Medtronic Concerto II CRT-D, Medtronic Consulta CRT-D and 14 more&lt;/p&gt;
&lt;p&gt;The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement encryption. An attacker with adjacent short-range access to a target product can listen to communications, including the transmission of sensitive data.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;&lt;strong&gt;Affected:&lt;/strong&gt; Medtronic Conexus Radio Frequency Telemetry Protocol, Medtronic MyCareLink Monitor, Medtronic CareLink Monitor, Medtronic CareLink 2090 Programmer, Medtronic Amplia CRT-D, Medtronic Claria CRT-D, Medtronic Compia CRT-D, Medtronic Concerto CRT-D, Medtronic Concerto II CRT-D, Medtronic Consulta CRT-D and 14 more&lt;/p&gt;
&lt;p&gt;The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement encryption. An attacker with adjacent short-range access to a target product can listen to communications, including the transmission of sensitive data.&lt;/p&gt;</content:encoded>