      <title>CVE-2018-16556</title>
      <link>https://cve.radiocsirt.org/vuln/cve-2018-16556</link>
      <description>&lt;p&gt;&lt;strong&gt;Affected:&lt;/strong&gt; Siemens SIMATIC S7-400 CPU 412-1 DP V7, Siemens SIMATIC S7-400 CPU 412-2 DP V7, Siemens SIMATIC S7-400 CPU 414-2 DP V7, Siemens SIMATIC S7-400 CPU 414-3 DP V7, Siemens SIMATIC S7-400 CPU 414-3 PN/DP V7, Siemens SIMATIC S7-400 CPU 414F-3 PN/DP V7, Siemens SIMATIC S7-400 CPU 416-2 DP V7, Siemens SIMATIC S7-400 CPU 416-3 DP V7, Siemens SIMATIC S7-400 CPU 416-3 PN/DP V7, Siemens SIMATIC S7-400 CPU 416F-2 DP V7 and 11 more&lt;/p&gt;
&lt;p&gt;A vulnerability has been identified in  SIMATIC S7-400 CPU 412-1 DP V7 (All versions),  SIMATIC S7-400 CPU 412-2 DP V7 (All versions),  SIMATIC S7-400 CPU 414-2 DP V7 (All versions),  SIMATIC S7-400 CPU 414-3 DP V7 (All versions),  SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions &amp;lt; V7.0.3),  SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions &amp;lt; V7.0.3),  SIMATIC S7-400 CPU 416-2 DP V7 (All versions),  SIMATIC S7-400 CPU 416-3 DP V7 (All versions),  SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions &amp;lt; V7.0.3),  SIMATIC S7-400 CPU 416F-2 DP V7 (All versions),  SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions &amp;lt; V7.0.3),  SIMATIC S7-400 CPU 417-4 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions &amp;lt; V7.0.3), SIMATIC S7-400 H V4.5 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions &amp;lt; V6.0.9), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions &amp;lt; V8.2.1), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions &amp;lt; V7.0.3), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions &amp;lt; V7.0.3), SIPLUS S7-400 CPU 416-3 V7 (All versions), SIPLUS S7-400 CPU 417-4 V7 (All versions). Specially crafted packets sent to port 102/tcp via Ethernet interface, via&#13;
PROFIBUS, or via Multi Point Interfaces (MPI) could cause the affected&#13;
devices to go into defect mode. Manual reboot is required to resume normal&#13;
operation.&#13;
&#13;
Successful exp…&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;&lt;strong&gt;Affected:&lt;/strong&gt; Siemens SIMATIC S7-400 CPU 412-1 DP V7, Siemens SIMATIC S7-400 CPU 412-2 DP V7, Siemens SIMATIC S7-400 CPU 414-2 DP V7, Siemens SIMATIC S7-400 CPU 414-3 DP V7, Siemens SIMATIC S7-400 CPU 414-3 PN/DP V7, Siemens SIMATIC S7-400 CPU 414F-3 PN/DP V7, Siemens SIMATIC S7-400 CPU 416-2 DP V7, Siemens SIMATIC S7-400 CPU 416-3 DP V7, Siemens SIMATIC S7-400 CPU 416-3 PN/DP V7, Siemens SIMATIC S7-400 CPU 416F-2 DP V7 and 11 more&lt;/p&gt;
&lt;p&gt;A vulnerability has been identified in  SIMATIC S7-400 CPU 412-1 DP V7 (All versions),  SIMATIC S7-400 CPU 412-2 DP V7 (All versions),  SIMATIC S7-400 CPU 414-2 DP V7 (All versions),  SIMATIC S7-400 CPU 414-3 DP V7 (All versions),  SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions &amp;lt; V7.0.3),  SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions &amp;lt; V7.0.3),  SIMATIC S7-400 CPU 416-2 DP V7 (All versions),  SIMATIC S7-400 CPU 416-3 DP V7 (All versions),  SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions &amp;lt; V7.0.3),  SIMATIC S7-400 CPU 416F-2 DP V7 (All versions),  SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions &amp;lt; V7.0.3),  SIMATIC S7-400 CPU 417-4 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions &amp;lt; V7.0.3), SIMATIC S7-400 H V4.5 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions &amp;lt; V6.0.9), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions &amp;lt; V8.2.1), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions &amp;lt; V7.0.3), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions &amp;lt; V7.0.3), SIPLUS S7-400 CPU 416-3 V7 (All versions), SIPLUS S7-400 CPU 417-4 V7 (All versions). Specially crafted packets sent to port 102/tcp via Ethernet interface, via&#13;
PROFIBUS, or via Multi Point Interfaces (MPI) could cause the affected&#13;
devices to go into defect mode. Manual reboot is required to resume normal&#13;
operation.&#13;
&#13;