<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Sat, 03 Oct 2026 21:52:50 +0000</lastBuildDate>
    <item>
      <title>CVE-2025-52586 — EG4 Electronics EG4 Inverters Cleartext Transmission of Sensitive Information</title>
      <link>https://cve.radiocsirt.org/vuln/cve-2025-52586</link>
      <description>&lt;p&gt;&lt;strong&gt;Affected:&lt;/strong&gt; EG4 Electronics EG4 12kPV, EG4 Electronics EG4 18kPV, EG4 Electronics EG4 Flex 21, EG4 Electronics EG4 Flex 18, EG4 Electronics EG4 6000XP, EG4 Electronics EG4 12000XP, EG4 Electronics EG4 GridBoss&lt;/p&gt;
&lt;p&gt;The MOD3 command traffic between the monitoring application and the 
inverter is transmitted in plaintext without encryption or obfuscation. 
This vulnerability may allow an attacker with access to a local network 
to intercept, manipulate, replay, or forge critical data, including 
read/write operations for voltage, current, and power configuration, 
operational status, alarms, telemetry, system reset, or inverter control
 commands, potentially disrupting power generation or reconfiguring 
inverter settings.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;&lt;strong&gt;Affected:&lt;/strong&gt; EG4 Electronics EG4 12kPV, EG4 Electronics EG4 18kPV, EG4 Electronics EG4 Flex 21, EG4 Electronics EG4 Flex 18, EG4 Electronics EG4 6000XP, EG4 Electronics EG4 12000XP, EG4 Electronics EG4 GridBoss&lt;/p&gt;
&lt;p&gt;The MOD3 command traffic between the monitoring application and the 
inverter is transmitted in plaintext without encryption or obfuscation. 
This vulnerability may allow an attacker with access to a local network 
to intercept, manipulate, replay, or forge critical data, including 
read/write operations for voltage, current, and power configuration, 
operational status, alarms, telemetry, system reset, or inverter control
 commands, potentially disrupting power generation or reconfiguring 
inverter settings.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/cve-2025-52586</guid>
    </item>
  </channel>
</rss>