<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Fri, 16 Oct 2026 04:45:14 +0000</lastBuildDate>
    <item>
      <title>EUVD-2026-273582</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-273582</link>
      <description>EUVD-2026-273582</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-273582</guid>
    </item>
    <item>
      <title>fkie_cve-2026-24487</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2026-24487</link>
      <description>&lt;p&gt;OpenEMR is a free and open source electronic health records and medical practice management application. Prior to version 8.0.0, an authorization bypass vulnerability in the FHIR CareTeam resource endpoint allows patient-scoped FHIR tokens to access care team data for all patients instead of being restricted to only the authenticated patient&amp;#39;s data. This could potentially lead to unauthorized disclosure of Protected Health Information (PHI), including patient-provider relationships and care team structures across the entire system. The issue occurs because the `FhirCareTeamService` does not implement the `IPatientCompartmentResourceService` interface and does not pass the patient binding parameter to the underlying service, bypassing the patient compartment filtering mechanism. Version 8.0.0 contains a patch for this issue.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;OpenEMR is a free and open source electronic health records and medical practice management application. Prior to version 8.0.0, an authorization bypass vulnerability in the FHIR CareTeam resource endpoint allows patient-scoped FHIR tokens to access care team data for all patients instead of being restricted to only the authenticated patient&amp;#39;s data. This could potentially lead to unauthorized disclosure of Protected Health Information (PHI), including patient-provider relationships and care team structures across the entire system. The issue occurs because the `FhirCareTeamService` does not implement the `IPatientCompartmentResourceService` interface and does not pass the patient binding parameter to the underlying service, bypassing the patient compartment filtering mechanism. Version 8.0.0 contains a patch for this issue.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2026-24487</guid>
    </item>
  </channel>
</rss>
