<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Fri, 02 Oct 2026 10:59:21 +0000</lastBuildDate>
    <item>
      <title>EUVD-2026-277847</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-277847</link>
      <description>EUVD-2026-277847</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-277847</guid>
    </item>
    <item>
      <title>fkie_cve-2025-4393</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2025-4393</link>
      <description>&lt;p&gt;Medtronic MyCareLink Patient Monitor has an internal service that deserializes data, which allows a local attacker to interact with the service by crafting a binary payload to crash the service or elevate privileges.&lt;/p&gt;
&lt;p&gt;This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Medtronic MyCareLink Patient Monitor has an internal service that deserializes data, which allows a local attacker to interact with the service by crafting a binary payload to crash the service or elevate privileges.&lt;/p&gt;
&lt;p&gt;This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2025-4393</guid>
    </item>
    <item>
      <title>GHSA-783m-53vh-rmp2</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-783m-53vh-rmp2</link>
      <description>&lt;p&gt;Medtronic MyCareLink Patient Monitor has an internal service that deserializes data, which allows a local attacker to interact with the service by crafting a binary payload to crash the service or elevate privileges.&lt;/p&gt;
&lt;p&gt;This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Medtronic MyCareLink Patient Monitor has an internal service that deserializes data, which allows a local attacker to interact with the service by crafting a binary payload to crash the service or elevate privileges.&lt;/p&gt;
&lt;p&gt;This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-783m-53vh-rmp2</guid>
    </item>
    <item>
      <title>ICSMA-25-205-01 — Medtronic MyCareLink Patient Monitor (Update A)</title>
      <link>https://cve.radiocsirt.org/vuln/icsma-25-205-01</link>
      <description>&lt;p&gt;Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files. Medtronic MyCareLink Patient Monitor has a built-in user account with an empty password, which allows an attacker with physical access to log in with no password and access/modify system functionality. Medtronic MyCareLink Patient Monitor has an internal service that deserializes data, which allows a local attacker to interact with the service by crafting a binary payload to crash the service or elevate privileges. Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials for network authentication. Medtronic MyCareLink Patient Monitor has an internal serial interface, which allows an attacker with physical access to access a login prompt via a UART terminal. Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials to modify encrypted drive data.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files. Medtronic MyCareLink Patient Monitor has a built-in user account with an empty password, which allows an attacker with physical access to log in with no password and access/modify system functionality. Medtronic MyCareLink Patient Monitor has an internal service that deserializes data, which allows a local attacker to interact with the service by crafting a binary payload to crash the service or elevate privileges. Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials for network authentication. Medtronic MyCareLink Patient Monitor has an internal serial interface, which allows an attacker with physical access to access a login prompt via a UART terminal. Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials to modify encrypted drive data.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsma-25-205-01</guid>
    </item>
  </channel>
</rss>
