<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Thu, 08 Oct 2026 03:33:26 +0000</lastBuildDate>
    <item>
      <title>EUVD-2026-273824</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-273824</link>
      <description>EUVD-2026-273824</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-273824</guid>
    </item>
    <item>
      <title>fkie_cve-2025-30042</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2025-30042</link>
      <description>&lt;p&gt;The CGM CLININET system provides smart card authentication; however, authentication is conducted locally on the client device, and, in reality, only the certificate number is used for access verification. As a result, possession of the certificate number alone is sufficient for authentication, regardless of the actual presence of the smart card or ownership of the private key.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;The CGM CLININET system provides smart card authentication; however, authentication is conducted locally on the client device, and, in reality, only the certificate number is used for access verification. As a result, possession of the certificate number alone is sufficient for authentication, regardless of the actual presence of the smart card or ownership of the private key.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2025-30042</guid>
    </item>
    <item>
      <title>GHSA-rfwf-h4fr-xr3g</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-rfwf-h4fr-xr3g</link>
      <description>&lt;p&gt;The CGM CLININET system provides smart card authentication; however, authentication is conducted locally on the client device, and, in reality, only the certificate number is used for access verification. As a result, possession of the certificate number alone is sufficient for authentication, regardless of the actual presence of the smart card or ownership of the private key.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;The CGM CLININET system provides smart card authentication; however, authentication is conducted locally on the client device, and, in reality, only the certificate number is used for access verification. As a result, possession of the certificate number alone is sufficient for authentication, regardless of the actual presence of the smart card or ownership of the private key.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-rfwf-h4fr-xr3g</guid>
    </item>
  </channel>
</rss>
