<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Tue, 06 Oct 2026 14:51:05 +0000</lastBuildDate>
    <item>
      <title>EUVD-2026-221771</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-221771</link>
      <description>EUVD-2026-221771</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-221771</guid>
    </item>
    <item>
      <title>fkie_cve-2024-43656</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2024-43656</link>
      <description>&lt;p&gt;Improper Neutralization of Special Elements used in a Command (&amp;#39;Command Injection&amp;#39;) vulnerability allows OS Command Injection as root&lt;/p&gt;
&lt;p&gt;This issue affects Iocharger firmware for AC model chargers before version 24120701.&lt;/p&gt;
&lt;p&gt;Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the &amp;lt;redated&amp;gt; directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file.&lt;/p&gt;
&lt;p&gt;Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.&lt;/p&gt;
&lt;p&gt;CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Improper Neutralization of Special Elements used in a Command (&amp;#39;Command Injection&amp;#39;) vulnerability allows OS Command Injection as root&lt;/p&gt;
&lt;p&gt;This issue affects Iocharger firmware for AC model chargers before version 24120701.&lt;/p&gt;
&lt;p&gt;Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the &amp;lt;redated&amp;gt; directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file.&lt;/p&gt;
&lt;p&gt;Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.&lt;/p&gt;
&lt;p&gt;CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2024-43656</guid>
    </item>
    <item>
      <title>GHSA-4pqh-gmhf-2qvf</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-4pqh-gmhf-2qvf</link>
      <description>&lt;p&gt;Improper Neutralization of Special Elements used in a Command (&amp;#39;Command Injection&amp;#39;) vulnerability allows OS Command Injection as root&lt;/p&gt;
&lt;p&gt;This issue affects Iocharger firmware for AC model chargers before version 24120701.&lt;/p&gt;
&lt;p&gt;Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the &amp;lt;redated&amp;gt; directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file.&lt;/p&gt;
&lt;p&gt;Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.&lt;/p&gt;
&lt;p&gt;CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Improper Neutralization of Special Elements used in a Command (&amp;#39;Command Injection&amp;#39;) vulnerability allows OS Command Injection as root&lt;/p&gt;
&lt;p&gt;This issue affects Iocharger firmware for AC model chargers before version 24120701.&lt;/p&gt;
&lt;p&gt;Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the &amp;lt;redated&amp;gt; directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file.&lt;/p&gt;
&lt;p&gt;Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.&lt;/p&gt;
&lt;p&gt;CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-4pqh-gmhf-2qvf</guid>
    </item>
  </channel>
</rss>
