<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Tue, 06 Oct 2026 10:31:33 +0000</lastBuildDate>
    <item>
      <title>cnvd-2025-04208</title>
      <link>https://cve.radiocsirt.org/vuln/cnvd-2025-04208</link>
      <description>cnvd-2025-04208</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/cnvd-2025-04208</guid>
    </item>
    <item>
      <title>EUVD-2026-221769</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-221769</link>
      <description>EUVD-2026-221769</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-221769</guid>
    </item>
    <item>
      <title>fkie_cve-2024-43655</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2024-43655</link>
      <description>&lt;p&gt;Improper Neutralization of Special Elements used in a Command (&amp;#39;Command Injection&amp;#39;) vulnerability allows OS Command Injection as root&lt;/p&gt;
&lt;p&gt;This issue affects Iocharger firmware for AC model chargers before version 24120701.&lt;/p&gt;
&lt;p&gt;Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it.&lt;/p&gt;
&lt;p&gt;Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.&lt;/p&gt;
&lt;p&gt;CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Improper Neutralization of Special Elements used in a Command (&amp;#39;Command Injection&amp;#39;) vulnerability allows OS Command Injection as root&lt;/p&gt;
&lt;p&gt;This issue affects Iocharger firmware for AC model chargers before version 24120701.&lt;/p&gt;
&lt;p&gt;Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it.&lt;/p&gt;
&lt;p&gt;Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.&lt;/p&gt;
&lt;p&gt;CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2024-43655</guid>
    </item>
    <item>
      <title>GHSA-2fff-928r-p76x</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-2fff-928r-p76x</link>
      <description>&lt;p&gt;Improper Neutralization of Special Elements used in a Command (&amp;#39;Command Injection&amp;#39;) vulnerability allows OS Command Injection as root&lt;/p&gt;
&lt;p&gt;This issue affects Iocharger firmware for AC model chargers before version 24120701.&lt;/p&gt;
&lt;p&gt;Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it.&lt;/p&gt;
&lt;p&gt;Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.&lt;/p&gt;
&lt;p&gt;CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Improper Neutralization of Special Elements used in a Command (&amp;#39;Command Injection&amp;#39;) vulnerability allows OS Command Injection as root&lt;/p&gt;
&lt;p&gt;This issue affects Iocharger firmware for AC model chargers before version 24120701.&lt;/p&gt;
&lt;p&gt;Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it.&lt;/p&gt;
&lt;p&gt;Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.&lt;/p&gt;
&lt;p&gt;CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).&lt;/p&gt;</content:encoded>