<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Mon, 05 Oct 2026 22:51:20 +0000</lastBuildDate>
    <item>
      <title>bdu:2024-00346</title>
      <link>https://cve.radiocsirt.org/vuln/bdu:2024-00346</link>
      <description>bdu:2024-00346</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/bdu:2024-00346</guid>
    </item>
    <item>
      <title>certfr-2024-avi-0014 — De multiples vulnérabilités ont été découvertes dans les produits
Siemens. Certaines d'entre elles permettent à un atta…</title>
      <link>https://cve.radiocsirt.org/vuln/certfr-2024-avi-0014</link>
      <description>certfr-2024-avi-0014</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/certfr-2024-avi-0014</guid>
    </item>
    <item>
      <title>cnvd-2024-01410</title>
      <link>https://cve.radiocsirt.org/vuln/cnvd-2024-01410</link>
      <description>cnvd-2024-01410</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/cnvd-2024-01410</guid>
    </item>
    <item>
      <title>EUVD-2026-242694</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-242694</link>
      <description>EUVD-2026-242694</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-242694</guid>
    </item>
    <item>
      <title>fkie_cve-2023-42797</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2023-42797</link>
      <description>&lt;p&gt;A vulnerability has been identified in CP-8031 MASTER MODULE (All versions &amp;lt; CPCI85 V05.20), CP-8050 MASTER MODULE (All versions &amp;lt; CPCI85 V05.20). The network configuration service of affected devices contains a flaw in the conversion of ipv4 addresses that could lead to an uninitialized variable being used in succeeding validation steps.&#13;
&#13;
By uploading specially crafted network configuration, an authenticated remote attacker could be able to inject commands that are executed on the device with root privileges during device startup.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A vulnerability has been identified in CP-8031 MASTER MODULE (All versions &amp;lt; CPCI85 V05.20), CP-8050 MASTER MODULE (All versions &amp;lt; CPCI85 V05.20). The network configuration service of affected devices contains a flaw in the conversion of ipv4 addresses that could lead to an uninitialized variable being used in succeeding validation steps.&#13;
&#13;
By uploading specially crafted network configuration, an authenticated remote attacker could be able to inject commands that are executed on the device with root privileges during device startup.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2023-42797</guid>
    </item>
    <item>
      <title>GHSA-j695-jhjg-w8vx</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-j695-jhjg-w8vx</link>
      <description>&lt;p&gt;A vulnerability has been identified in CP-8031 MASTER MODULE (All versions &amp;lt; CPCI85 V05.20), CP-8050 MASTER MODULE (All versions &amp;lt; CPCI85 V05.20). The network configuration service of affected devices contains a flaw in the conversion of ipv4 addresses that could lead to an uninitialized variable being used in succeeding validation steps.&lt;/p&gt;
&lt;p&gt;By uploading specially crafted network configuration, an authenticated remote attacker could be able to inject commands that are executed on the device with root privileges during device startup.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A vulnerability has been identified in CP-8031 MASTER MODULE (All versions &amp;lt; CPCI85 V05.20), CP-8050 MASTER MODULE (All versions &amp;lt; CPCI85 V05.20). The network configuration service of affected devices contains a flaw in the conversion of ipv4 addresses that could lead to an uninitialized variable being used in succeeding validation steps.&lt;/p&gt;
&lt;p&gt;By uploading specially crafted network configuration, an authenticated remote attacker could be able to inject commands that are executed on the device with root privileges during device startup.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-j695-jhjg-w8vx</guid>
    </item>
    <item>
      <title>gsd-2023-42797</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2023-42797</link>
      <description>gsd-2023-42797</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2023-42797</guid>
    </item>
    <item>
      <title>ICSA-24-011-08 — Siemens SICAM A8000</title>
      <link>https://cve.radiocsirt.org/vuln/icsa-24-011-08</link>
      <description>&lt;p&gt;The network configuration service of affected devices contains a flaw in the conversion of ipv4 addresses that could lead to an uninitialized variable being used in succeeding validation steps.&#13;
&#13;
By uploading specially crafted network configuration, an authenticated remote attacker could be able to inject commands that are executed on the device with root privileges during device startup.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;The network configuration service of affected devices contains a flaw in the conversion of ipv4 addresses that could lead to an uninitialized variable being used in succeeding validation steps.&#13;
&#13;
By uploading specially crafted network configuration, an authenticated remote attacker could be able to inject commands that are executed on the device with root privileges during device startup.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsa-24-011-08</guid>
    </item>
    <item>
      <title>WID-SEC-W-2024-0030 — Siemens SICAM A8000: Schwachstelle ermöglicht Ausführen von beliebigem Programmcode mit Administratorrechten</title>
      <link>https://cve.radiocsirt.org/vuln/wid-sec-w-2024-0030</link>
      <description>&lt;p&gt;Ein entfernter, authentisierter Angreifer kann eine Schwachstelle in Siemens SICAM A8000 ausnutzen, um beliebigen Programmcode mit Administratorrechten auszuführen.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Ein entfernter, authentisierter Angreifer kann eine Schwachstelle in Siemens SICAM A8000 ausnutzen, um beliebigen Programmcode mit Administratorrechten auszuführen.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/wid-sec-w-2024-0030</guid>
    </item>
  </channel>
</rss>
