    <item>
      <title>bdu:2023-01760</title>
      <link>https://cve.radiocsirt.org/vuln/bdu:2023-01760</link>
      <description>bdu:2023-01760</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/bdu:2023-01760</guid>
    </item>
    <item>
      <title>cnvd-2023-21677</title>
      <link>https://cve.radiocsirt.org/vuln/cnvd-2023-21677</link>
      <description>cnvd-2023-21677</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/cnvd-2023-21677</guid>
    </item>
    <item>
      <title>EUVD-2026-210956</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-210956</link>
      <description>EUVD-2026-210956</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-210956</guid>
    </item>
    <item>
      <title>fkie_cve-2023-22807</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2023-22807</link>
      <description>&lt;p&gt;LS ELECTRIC XBC-DN32U with operating system version 01.80 does not properly control access to the PLC over its internal XGT protocol.  An attacker could control and tamper with the PLC by sending the packets to the PLC over its XGT protocol.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;LS ELECTRIC XBC-DN32U with operating system version 01.80 does not properly control access to the PLC over its internal XGT protocol.  An attacker could control and tamper with the PLC by sending the packets to the PLC over its XGT protocol.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2023-22807</guid>
    </item>
    <item>
      <title>GHSA-qvrw-w6hg-g36x</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-qvrw-w6hg-g36x</link>
      <description>&lt;p&gt;LS ELECTRIC XBC-DN32U with operating system version 01.80 does not properly control access to the PLC over its internal XGT protocol. An attacker could control and tamper with the PLC by sending the packets to the PLC over its XGT protocol.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;LS ELECTRIC XBC-DN32U with operating system version 01.80 does not properly control access to the PLC over its internal XGT protocol. An attacker could control and tamper with the PLC by sending the packets to the PLC over its XGT protocol.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-qvrw-w6hg-g36x</guid>
    </item>
    <item>
      <title>gsd-2023-22807</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2023-22807</link>
      <description>gsd-2023-22807</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2023-22807</guid>
    </item>
    <item>
      <title>ICSA-23-040-02 — LS ELECTRIC XBC-DN32U</title>
      <link>https://cve.radiocsirt.org/vuln/icsa-23-040-02</link>
      <description>&lt;p&gt;LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to perform critical functions to the PLC. This could allow an attacker to change the PLC&amp;#39;s mode arbitrarily.-CVE-2023-22803 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to create users on the PLC. This could allow an attacker to create and use an account with elevated privileges and take control of the device.-CVE-2023-22804 has been assigned to this vulnerability. A CVSS v3 base score of 9.1 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H). LS ELECTRIC XBC-DN32U with operating system version 01.80 has improper access control to its read prohibition feature. This could allow a remote attacker to remotely set the feature to lock users out of reading data from the device.-CVE-2023-22805 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H). LS ELECTRIC XBC-DN32U with operating system version 01.80 transmits sensitive information in cleartext when communicating over its XGT protocol. This could allow an attacker to gain sensitive information, such as user credentials.-CVE-2023-22806 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS…&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to perform critical functions to the PLC. This could allow an attacker to change the PLC&amp;#39;s mode arbitrarily.-CVE-2023-22803 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to create users on the PLC. This could allow an attacker to create and use an account with elevated privileges and take control of the device.-CVE-2023-22804 has been assigned to this vulnerability. A CVSS v3 base score of 9.1 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H). LS ELECTRIC XBC-DN32U with operating system version 01.80 has improper access control to its read prohibition feature. This could allow a remote attacker to remotely set the feature to lock users out of reading data from the device.-CVE-2023-22805 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H). LS ELECTRIC XBC-DN32U with operating system version 01.80 transmits sensitive information in cleartext when communicating over its XGT protocol. This could allow an attacker to gain sensitive information, such as user credentials.-CVE-2023-22806 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS…&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsa-23-040-02</guid>
    </item>