<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Sat, 10 Oct 2026 21:53:38 +0000</lastBuildDate>
    <item>
      <title>bdu:2022-03765</title>
      <link>https://cve.radiocsirt.org/vuln/bdu:2022-03765</link>
      <description>bdu:2022-03765</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/bdu:2022-03765</guid>
    </item>
    <item>
      <title>EUVD-2026-16788</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-16788</link>
      <description>EUVD-2026-16788</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-16788</guid>
    </item>
    <item>
      <title>fkie_cve-2022-31205</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2022-31205</link>
      <description>&lt;p&gt;In Omron CS series, CJ series, and CP series PLCs through 2022-05-18, the password for access to the Web UI is stored in memory area D1449...D1452 and can be read out using the Omron FINS protocol without any further authentication.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;In Omron CS series, CJ series, and CP series PLCs through 2022-05-18, the password for access to the Web UI is stored in memory area D1449...D1452 and can be read out using the Omron FINS protocol without any further authentication.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2022-31205</guid>
    </item>
    <item>
      <title>GHSA-c5rh-wr27-mrw6</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-c5rh-wr27-mrw6</link>
      <description>&lt;p&gt;In Omron CS series, CJ series, and CP series PLCs through 2022-05-18, the password for access to the Web UI is stored in memory area D1449...D1452 and can be read out using the Omron FINS protocol without any further authentication.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;In Omron CS series, CJ series, and CP series PLCs through 2022-05-18, the password for access to the Web UI is stored in memory area D1449...D1452 and can be read out using the Omron FINS protocol without any further authentication.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-c5rh-wr27-mrw6</guid>
    </item>
    <item>
      <title>gsd-2022-31205</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2022-31205</link>
      <description>gsd-2022-31205</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2022-31205</guid>
    </item>
    <item>
      <title>ICSA-22-179-02 — Omron SYSMAC CS/CJ/CP Series and NJ/NX Series</title>
      <link>https://cve.radiocsirt.org/vuln/icsa-22-179-02</link>
      <description>&lt;p&gt;Omron SYSMAC CS1/CJ1/CP1/CP2 series is vulnerable to a password used to restrict engineering operation is transmitted in plaintext. CVE-2022-31204 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N). The CP1W-CIF41 Ethernet Option Board is vulnerable to a Web UI password that can be read from memory using the Omron FINS protocol. An attacker obtaining this password could change the network settings of the option board. CVE-2022-31205 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N). The logic that is downloaded to the PLC is not cryptographically authenticated, allowing an attacker to manipulate transmitted object code to an unprotected PLC without using the PLC protection password. An attacker could then execute arbitrary object code commands on the defined software logic for all versions of SYSMAC CS/CJ/CP series controllers and cause a denial-of-service condition. CVE-2022-31207 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:H). The logic that is downloaded to the PLC is not cryptographically authenticated, allowing an attacker to manipulate transmitted object code to the PLC and execute arbitrary machine code on the processor of the PLC&amp;#39;s CPU module for SYSMAC NJ/NX serie…&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Omron SYSMAC CS1/CJ1/CP1/CP2 series is vulnerable to a password used to restrict engineering operation is transmitted in plaintext. CVE-2022-31204 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N). The CP1W-CIF41 Ethernet Option Board is vulnerable to a Web UI password that can be read from memory using the Omron FINS protocol. An attacker obtaining this password could change the network settings of the option board. CVE-2022-31205 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N). The logic that is downloaded to the PLC is not cryptographically authenticated, allowing an attacker to manipulate transmitted object code to an unprotected PLC without using the PLC protection password. An attacker could then execute arbitrary object code commands on the defined software logic for all versions of SYSMAC CS/CJ/CP series controllers and cause a denial-of-service condition. CVE-2022-31207 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:H). The logic that is downloaded to the PLC is not cryptographically authenticated, allowing an attacker to manipulate transmitted object code to the PLC and execute arbitrary machine code on the processor of the PLC&amp;#39;s CPU module for SYSMAC NJ/NX serie…&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsa-22-179-02</guid>
    </item>
  </channel>
</rss>