<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Sat, 17 Oct 2026 20:42:47 +0000</lastBuildDate>
    <item>
      <title>bdu:2023-04550</title>
      <link>https://cve.radiocsirt.org/vuln/bdu:2023-04550</link>
      <description>bdu:2023-04550</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/bdu:2023-04550</guid>
    </item>
    <item>
      <title>EUVD-2026-220608</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-220608</link>
      <description>EUVD-2026-220608</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-220608</guid>
    </item>
    <item>
      <title>fkie_cve-2022-2502</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2022-2502</link>
      <description>&lt;p&gt;A vulnerability exists in the HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-5 and the CMU contains the license feature ‘Advanced security’ which must be ordered separately. If these preconditions are fulfilled, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the targeted RTU500 CMU to reboot. The vulnerability is caused by a missing input data validation which eventually if exploited causes an internal buffer to overflow in the HCI IEC 60870-5-104 function.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A vulnerability exists in the HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-5 and the CMU contains the license feature ‘Advanced security’ which must be ordered separately. If these preconditions are fulfilled, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the targeted RTU500 CMU to reboot. The vulnerability is caused by a missing input data validation which eventually if exploited causes an internal buffer to overflow in the HCI IEC 60870-5-104 function.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2022-2502</guid>
    </item>
    <item>
      <title>GHSA-45rh-q5fv-wf42</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-45rh-q5fv-wf42</link>
      <description>&lt;p&gt;A vulnerability exists in the HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-5 and the CMU contains the license feature ‘Advanced security’ which must be ordered separately. If these preconditions are fulfilled, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the targeted RTU500 CMU to reboot. The vulnerability is caused by a missing input data validation which eventually if exploited causes an internal buffer to overflow in the HCI IEC 60870-5-104 function.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A vulnerability exists in the HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-5 and the CMU contains the license feature ‘Advanced security’ which must be ordered separately. If these preconditions are fulfilled, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the targeted RTU500 CMU to reboot. The vulnerability is caused by a missing input data validation which eventually if exploited causes an internal buffer to overflow in the HCI IEC 60870-5-104 function.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-45rh-q5fv-wf42</guid>
    </item>
    <item>
      <title>gsd-2022-2502</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2022-2502</link>
      <description>gsd-2022-2502</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2022-2502</guid>
    </item>
    <item>
      <title>ICSA-23-220-02 — Hitachi Energy RTU500 series</title>
      <link>https://cve.radiocsirt.org/vuln/icsa-23-220-02</link>
      <description>&lt;p&gt;A vulnerability exists in the HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited if the HCI 60870-5-104 is configured with IEC 62351-5 support and the CMU contains the license feature &amp;#39;Advanced security&amp;#39; which must be ordered separately. If these preconditions are fulfilled, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the targeted RTU500 CMU to reboot. The vulnerability is caused by a missing input data validation, which eventually, if exploited, could cause an internal buffer to overflow in the HCI IEC 60870-5-104 function. A vulnerability exists in HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited if the HCI 60870-5-104 is configured with support for IEC 62351-3. After session resumption interval is expired, an RTU500 initiated update of session parameters could cause an unexpected restart due to a stack overflow.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A vulnerability exists in the HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited if the HCI 60870-5-104 is configured with IEC 62351-5 support and the CMU contains the license feature &amp;#39;Advanced security&amp;#39; which must be ordered separately. If these preconditions are fulfilled, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the targeted RTU500 CMU to reboot. The vulnerability is caused by a missing input data validation, which eventually, if exploited, could cause an internal buffer to overflow in the HCI IEC 60870-5-104 function. A vulnerability exists in HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited if the HCI 60870-5-104 is configured with support for IEC 62351-3. After session resumption interval is expired, an RTU500 initiated update of session parameters could cause an unexpected restart due to a stack overflow.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsa-23-220-02</guid>
    </item>
    <item>
      <title>WID-SEC-W-2023-2016 — Hitachi Energy RTU500: Mehrere Schwachstellen</title>
      <link>https://cve.radiocsirt.org/vuln/wid-sec-w-2023-2016</link>
      <description>&lt;p&gt;Ein entfernter, anonymer Angreifer kann mehrere Schwachstellen in Hitachi Energy RTU500 ausnutzen, um einen Denial of Service Angriff durchzuführen.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Ein entfernter, anonymer Angreifer kann mehrere Schwachstellen in Hitachi Energy RTU500 ausnutzen, um einen Denial of Service Angriff durchzuführen.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/wid-sec-w-2023-2016</guid>
    </item>
  </channel>
</rss>
