<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Thu, 08 Oct 2026 16:41:04 +0000</lastBuildDate>
    <item>
      <title>cnvd-2019-28110</title>
      <link>https://cve.radiocsirt.org/vuln/cnvd-2019-28110</link>
      <description>cnvd-2019-28110</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/cnvd-2019-28110</guid>
    </item>
    <item>
      <title>EUVD-2026-54085</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-54085</link>
      <description>EUVD-2026-54085</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-54085</guid>
    </item>
    <item>
      <title>fkie_cve-2019-10980</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2019-10980</link>
      <description>&lt;p&gt;A type confusion vulnerability may be exploited when LAquis SCADA 4.3.1.71 processes a specially crafted project file. This may allow an attacker to execute remote code. The attacker must have local access to the system. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A type confusion vulnerability may be exploited when LAquis SCADA 4.3.1.71 processes a specially crafted project file. This may allow an attacker to execute remote code. The attacker must have local access to the system. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2019-10980</guid>
    </item>
    <item>
      <title>GHSA-3qf9-f692-8xjh</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-3qf9-f692-8xjh</link>
      <description>&lt;p&gt;A type confusion vulnerability may be exploited when LAquis SCADA 4.3.1.71 processes a specially crafted project file. This may allow an attacker to execute remote code. The attacker must have local access to the system. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A type confusion vulnerability may be exploited when LAquis SCADA 4.3.1.71 processes a specially crafted project file. This may allow an attacker to execute remote code. The attacker must have local access to the system. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-3qf9-f692-8xjh</guid>
    </item>
    <item>
      <title>gsd-2019-10980</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2019-10980</link>
      <description>gsd-2019-10980</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2019-10980</guid>
    </item>
    <item>
      <title>ICSA-19-213-06 — LCDS LAquis SCADA LQS File Parsing</title>
      <link>https://cve.radiocsirt.org/vuln/icsa-19-213-06</link>
      <description>&lt;p&gt;Processing a specially crafted project file may trigger an out-of-bounds read, which may allow an attacker to obtain sensitive information.CVE-2019-10994 has been assigned to this vulnerability. A CVSS v3 base score of 2.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N/UI:R/S:U/C:L/I:N/A:N). A type confusion vulnerability may be exploited when LAquis SCADA processes a specially crafted project file. This may allow an attacker to execute remote code.CVE-2019-10980 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Processing a specially crafted project file may trigger an out-of-bounds read, which may allow an attacker to obtain sensitive information.CVE-2019-10994 has been assigned to this vulnerability. A CVSS v3 base score of 2.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N/UI:R/S:U/C:L/I:N/A:N). A type confusion vulnerability may be exploited when LAquis SCADA processes a specially crafted project file. This may allow an attacker to execute remote code.CVE-2019-10980 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsa-19-213-06</guid>
    </item>