<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Tue, 06 Oct 2026 22:54:16 +0000</lastBuildDate>
    <item>
      <title>bdu:2019-01021</title>
      <link>https://cve.radiocsirt.org/vuln/bdu:2019-01021</link>
      <description>bdu:2019-01021</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/bdu:2019-01021</guid>
    </item>
    <item>
      <title>certfr-2018-avi-543 — De multiples vulnérabilités ont été découvertes dans les produits
Siemens . Certaines d'entre elles permettent à un att…</title>
      <link>https://cve.radiocsirt.org/vuln/certfr-2018-avi-543</link>
      <description>certfr-2018-avi-543</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/certfr-2018-avi-543</guid>
    </item>
    <item>
      <title>cnvd-2018-25433</title>
      <link>https://cve.radiocsirt.org/vuln/cnvd-2018-25433</link>
      <description>cnvd-2018-25433</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/cnvd-2018-25433</guid>
    </item>
    <item>
      <title>EUVD-2026-68199</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-68199</link>
      <description>EUVD-2026-68199</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-68199</guid>
    </item>
    <item>
      <title>fkie_cve-2018-16556</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2018-16556</link>
      <description>&lt;p&gt;A vulnerability has been identified in  SIMATIC S7-400 CPU 412-1 DP V7 (All versions),  SIMATIC S7-400 CPU 412-2 DP V7 (All versions),  SIMATIC S7-400 CPU 414-2 DP V7 (All versions),  SIMATIC S7-400 CPU 414-3 DP V7 (All versions),  SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions &amp;lt; V7.0.3),  SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions &amp;lt; V7.0.3),  SIMATIC S7-400 CPU 416-2 DP V7 (All versions),  SIMATIC S7-400 CPU 416-3 DP V7 (All versions),  SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions &amp;lt; V7.0.3),  SIMATIC S7-400 CPU 416F-2 DP V7 (All versions),  SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions &amp;lt; V7.0.3),  SIMATIC S7-400 CPU 417-4 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions &amp;lt; V7.0.3), SIMATIC S7-400 H V4.5 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions &amp;lt; V6.0.9), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions &amp;lt; V8.2.1), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions &amp;lt; V7.0.3), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions &amp;lt; V7.0.3), SIPLUS S7-400 CPU 416-3 V7 (All versions), SIPLUS S7-400 CPU 417-4 V7 (All versions). Specially crafted packets sent to port 102/tcp via Ethernet interface, via&#13;
PROFIBUS, or via Multi Point Interfaces (MPI) could cause the affected&#13;
devices to go into defect mode. Manual reboot is required to resume normal&#13;
operation.&#13;
&#13;
Successful exp…&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A vulnerability has been identified in  SIMATIC S7-400 CPU 412-1 DP V7 (All versions),  SIMATIC S7-400 CPU 412-2 DP V7 (All versions),  SIMATIC S7-400 CPU 414-2 DP V7 (All versions),  SIMATIC S7-400 CPU 414-3 DP V7 (All versions),  SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions &amp;lt; V7.0.3),  SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions &amp;lt; V7.0.3),  SIMATIC S7-400 CPU 416-2 DP V7 (All versions),  SIMATIC S7-400 CPU 416-3 DP V7 (All versions),  SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions &amp;lt; V7.0.3),  SIMATIC S7-400 CPU 416F-2 DP V7 (All versions),  SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions &amp;lt; V7.0.3),  SIMATIC S7-400 CPU 417-4 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions &amp;lt; V7.0.3), SIMATIC S7-400 H V4.5 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions &amp;lt; V6.0.9), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions &amp;lt; V8.2.1), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions &amp;lt; V7.0.3), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions &amp;lt; V7.0.3), SIPLUS S7-400 CPU 416-3 V7 (All versions), SIPLUS S7-400 CPU 417-4 V7 (All versions). Specially crafted packets sent to port 102/tcp via Ethernet interface, via&#13;
PROFIBUS, or via Multi Point Interfaces (MPI) could cause the affected&#13;
devices to go into defect mode. Manual reboot is required to resume normal&#13;
operation.&#13;
&#13;
Successful exp…&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2018-16556</guid>
    </item>
    <item>
      <title>GHSA-h69h-mwxm-xg4v</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-h69h-mwxm-xg4v</link>
      <description>&lt;p&gt;A vulnerability has been identified in SIMATIC S7-400 (incl. F) V6 and below (All versions), SIMATIC S7-400 PN/DP V7 (incl. F) (All versions), SIMATIC S7-400H V4.5 and below (All versions), SIMATIC S7-400H V6 (All versions &amp;lt; V6.0.9), SIMATIC S7-410 (All versions &amp;lt; V8.2.1). Specially crafted packets sent to port 102/tcp via Ethernet interface, via PROFIBUS, or via Multi Point Interfaces (MPI) could cause the affected devices to go into defect mode. Manual reboot is required to resume normal operation. Successful exploitation requires an attacker to be able to send specially crafted packets to port 102/tcp via Ethernet interface, via PROFIBUS or Multi Point Interfaces (MPI). No user interaction and no user privileges are required to exploit the security vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the core functionality of the CPU, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A vulnerability has been identified in SIMATIC S7-400 (incl. F) V6 and below (All versions), SIMATIC S7-400 PN/DP V7 (incl. F) (All versions), SIMATIC S7-400H V4.5 and below (All versions), SIMATIC S7-400H V6 (All versions &amp;lt; V6.0.9), SIMATIC S7-410 (All versions &amp;lt; V8.2.1). Specially crafted packets sent to port 102/tcp via Ethernet interface, via PROFIBUS, or via Multi Point Interfaces (MPI) could cause the affected devices to go into defect mode. Manual reboot is required to resume normal operation. Successful exploitation requires an attacker to be able to send specially crafted packets to port 102/tcp via Ethernet interface, via PROFIBUS or Multi Point Interfaces (MPI). No user interaction and no user privileges are required to exploit the security vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the core functionality of the CPU, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-h69h-mwxm-xg4v</guid>
    </item>
    <item>
      <title>gsd-2018-16556</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2018-16556</link>
      <description>gsd-2018-16556</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2018-16556</guid>
    </item>
    <item>
      <title>ICSA-18-317-02 — Siemens S7-400 CPUs (Update B)</title>
      <link>https://cve.radiocsirt.org/vuln/icsa-18-317-02</link>
      <description>&lt;p&gt;Specially crafted packets sent to port 102/tcp via Ethernet interface, via&#13;
PROFIBUS, or via Multi Point Interfaces (MPI) could cause the affected&#13;
devices to go into defect mode. Manual reboot is required to resume normal&#13;
operation.&#13;
&#13;
Successful exploitation requires an attacker to be able to send specially&#13;
crafted packets to port 102/tcp via Ethernet interface, via PROFIBUS or Multi&#13;
Point Interfaces (MPI). No user interaction and no user privileges are&#13;
required to exploit the security vulnerability. The vulnerability could allow&#13;
causing a denial of service condition of the core functionality of the CPU,&#13;
compromising the availability of the system. Sending of specially crafted packets to port 102/tcp via Ethernet interface&#13;
via PROFIBUS or Multi Point Interfaces (MPI) could cause a denial of service&#13;
condition on affected devices. Flashing with a firmware image may be required&#13;
to recover the CPU.&#13;
&#13;
Successful exploitation requires an attacker to have network access to port&#13;
102/tcp via Ethernet interface or to be able to send messages via PROFIBUS or&#13;
Multi Point Interfaces (MPI) to the device. No user interaction is required.&#13;
If no access protection is configured, no privileges are required to exploit&#13;
the security vulnerability. The vulnerability could allow causing a&#13;
denial of service condition of the core functionality of the CPU,&#13;
compromising the availability of the system.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Specially crafted packets sent to port 102/tcp via Ethernet interface, via&#13;
PROFIBUS, or via Multi Point Interfaces (MPI) could cause the affected&#13;
devices to go into defect mode. Manual reboot is required to resume normal&#13;
operation.&#13;
&#13;
Successful exploitation requires an attacker to be able to send specially&#13;
crafted packets to port 102/tcp via Ethernet interface, via PROFIBUS or Multi&#13;
Point Interfaces (MPI). No user interaction and no user privileges are&#13;
required to exploit the security vulnerability. The vulnerability could allow&#13;
causing a denial of service condition of the core functionality of the CPU,&#13;
compromising the availability of the system. Sending of specially crafted packets to port 102/tcp via Ethernet interface&#13;
via PROFIBUS or Multi Point Interfaces (MPI) could cause a denial of service&#13;
condition on affected devices. Flashing with a firmware image may be required&#13;
to recover the CPU.&#13;
&#13;
Successful exploitation requires an attacker to have network access to port&#13;
102/tcp via Ethernet interface or to be able to send messages via PROFIBUS or&#13;
Multi Point Interfaces (MPI) to the device. No user interaction is required.&#13;
If no access protection is configured, no privileges are required to exploit&#13;
the security vulnerability. The vulnerability could allow causing a&#13;
denial of service condition of the core functionality of the CPU,&#13;
compromising the availability of the system.&lt;/p&gt;</content:encoded>