<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Thu, 15 Oct 2026 09:10:55 +0000</lastBuildDate>
    <item>
      <title>cnvd-2018-10590</title>
      <link>https://cve.radiocsirt.org/vuln/cnvd-2018-10590</link>
      <description>cnvd-2018-10590</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/cnvd-2018-10590</guid>
    </item>
    <item>
      <title>EUVD-2026-173291</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-173291</link>
      <description>EUVD-2026-173291</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-173291</guid>
    </item>
    <item>
      <title>fkie_cve-2018-10607</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2018-10607</link>
      <description>&lt;p&gt;Martem TELEM GW6 and GWM devices with firmware 2018.04.18-linux_4-01-601cb47 and prior allow the creation of new connections to one or more IOAs, without closing them properly, which may cause a denial of service within the industrial process control channel.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Martem TELEM GW6 and GWM devices with firmware 2018.04.18-linux_4-01-601cb47 and prior allow the creation of new connections to one or more IOAs, without closing them properly, which may cause a denial of service within the industrial process control channel.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2018-10607</guid>
    </item>
    <item>
      <title>GHSA-v39j-f7jx-49hv</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-v39j-f7jx-49hv</link>
      <description>&lt;p&gt;Martem TELEM GW6 and GWM devices with firmware 2018.04.18-linux_4-01-601cb47 and prior allow the creation of new connections to one or more IOAs, without closing them properly, which may cause a denial of service within the industrial process control channel.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Martem TELEM GW6 and GWM devices with firmware 2018.04.18-linux_4-01-601cb47 and prior allow the creation of new connections to one or more IOAs, without closing them properly, which may cause a denial of service within the industrial process control channel.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-v39j-f7jx-49hv</guid>
    </item>
    <item>
      <title>gsd-2018-10607</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2018-10607</link>
      <description>gsd-2018-10607</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2018-10607</guid>
    </item>
    <item>
      <title>ICSA-18-142-01 — Martem TELEM-GW6/GWM (Update B)</title>
      <link>https://cve.radiocsirt.org/vuln/icsa-18-142-01</link>
      <description>&lt;p&gt;The RTU does not perform authentication of IEC-104 control commands, which may allow a rogue node a remote control of the industrial process.CVE-2018-10603 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L). Using default credentials to connect to the RTU, unprivileged user may modify/upload a new system configuration or take the full control over the RTU.CVE-2018-10605 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). Creating new connections to one or more IOAs, without closing them properly, may cause a denial of service within the industrial process control channel.CVE-2018-10607 has been assigned to this vulnerability. A CVSS v3 base score of 8.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H). Improper sanitization of data over a Websocket may allow cross-site scripting and client-side code execution with target user privileges.CVE-2018-10609 has been assigned to this vulnerability. A CVSS v3 base score of 7.4 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:C/C:N/I:H/A:N).&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;The RTU does not perform authentication of IEC-104 control commands, which may allow a rogue node a remote control of the industrial process.CVE-2018-10603 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L). Using default credentials to connect to the RTU, unprivileged user may modify/upload a new system configuration or take the full control over the RTU.CVE-2018-10605 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). Creating new connections to one or more IOAs, without closing them properly, may cause a denial of service within the industrial process control channel.CVE-2018-10607 has been assigned to this vulnerability. A CVSS v3 base score of 8.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H). Improper sanitization of data over a Websocket may allow cross-site scripting and client-side code execution with target user privileges.CVE-2018-10609 has been assigned to this vulnerability. A CVSS v3 base score of 7.4 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:C/C:N/I:H/A:N).&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsa-18-142-01</guid>
    </item>
  </channel>
</rss>
