    <item>
      <title>certfr-2016-avi-405 — De multiples vulnérabilités ont été corrigées dans &lt;span
class="textit"&gt;SCADA Siemens SIMATIC&lt;/span&gt;. Elles permettent…</title>
      <link>https://cve.radiocsirt.org/vuln/certfr-2016-avi-405</link>
      <description>certfr-2016-avi-405</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/certfr-2016-avi-405</guid>
    </item>
    <item>
      <title>cnvd-2016-12694</title>
      <link>https://cve.radiocsirt.org/vuln/cnvd-2016-12694</link>
      <description>cnvd-2016-12694</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/cnvd-2016-12694</guid>
    </item>
    <item>
      <title>EUVD-2026-324162</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-324162</link>
      <description>EUVD-2026-324162</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-324162</guid>
    </item>
    <item>
      <title>fkie_cve-2016-9159</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2016-9159</link>
      <description>&lt;p&gt;A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions), SIMATIC S7-410 V8 CPU family (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions). An attacker with network access to port 102/tcp (ISO-TSAP) or via Profibus could obtain credentials from the PLC if protection-level 2 is configured on the affected devices.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions), SIMATIC S7-410 V8 CPU family (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions). An attacker with network access to port 102/tcp (ISO-TSAP) or via Profibus could obtain credentials from the PLC if protection-level 2 is configured on the affected devices.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2016-9159</guid>
    </item>
    <item>
      <title>GHSA-xx5q-4wf5-7xrj</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-xx5q-4wf5-7xrj</link>
      <description>&lt;p&gt;A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions), SIMATIC S7-410 V8 CPU family (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions). An attacker with network access to port 102/tcp (ISO-TSAP) or via Profibus could obtain credentials from the PLC if protection-level 2 is configured on the affected devices.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions), SIMATIC S7-410 V8 CPU family (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions). An attacker with network access to port 102/tcp (ISO-TSAP) or via Profibus could obtain credentials from the PLC if protection-level 2 is configured on the affected devices.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-xx5q-4wf5-7xrj</guid>