<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Fri, 02 Oct 2026 10:14:12 +0000</lastBuildDate>
    <item>
      <title>CVE-2019-18336</title>
      <link>https://cve.radiocsirt.org/vuln/cve-2019-18336</link>
      <description>&lt;p&gt;&lt;strong&gt;Affected:&lt;/strong&gt; Siemens AG SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants), Siemens AG SIMATIC TDC CP51M1, Siemens AG SIMATIC TDC CPU555, Siemens AG SINUMERIK 840D sl&lt;/p&gt;
&lt;p&gt;A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions &amp;lt; V3.X.17), SIMATIC TDC CP51M1 (All versions &amp;lt; V1.1.8), SIMATIC TDC CPU555 (All versions &amp;lt; V1.1.1), SINUMERIK 840D sl (All versions &amp;lt; V4.8.6), SINUMERIK 840D sl (All versions &amp;lt; V4.94). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;&lt;strong&gt;Affected:&lt;/strong&gt; Siemens AG SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants), Siemens AG SIMATIC TDC CP51M1, Siemens AG SIMATIC TDC CPU555, Siemens AG SINUMERIK 840D sl&lt;/p&gt;
&lt;p&gt;A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions &amp;lt; V3.X.17), SIMATIC TDC CP51M1 (All versions &amp;lt; V1.1.8), SIMATIC TDC CPU555 (All versions &amp;lt; V1.1.1), SINUMERIK 840D sl (All versions &amp;lt; V4.8.6), SINUMERIK 840D sl (All versions &amp;lt; V4.94). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/cve-2019-18336</guid>
    </item>
  </channel>
</rss>
