<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Mon, 12 Oct 2026 06:37:51 +0000</lastBuildDate>
    <item>
      <title>CVE-2024-43781</title>
      <link>https://cve.radiocsirt.org/vuln/cve-2024-43781</link>
      <description>&lt;p&gt;&lt;strong&gt;Affected:&lt;/strong&gt; Siemens SINUMERIK 828D V4, Siemens SINUMERIK 840D sl V4, Siemens SINUMERIK ONE&lt;/p&gt;
&lt;p&gt;A vulnerability has been identified in SINUMERIK 828D V4 (All versions &amp;lt; V4.95 SP3), SINUMERIK 840D sl V4 (All versions &amp;lt; V4.95 SP3 in connection with using Create MyConfig (CMC) &amp;lt;= V4.8 SP1 HF6), SINUMERIK ONE (All versions &amp;lt; V6.23 in connection with using Create MyConfig (CMC) &amp;lt;= V6.6), SINUMERIK ONE (All versions &amp;lt; V6.15 SP4 in connection with using Create MyConfig (CMC) &amp;lt;= V6.6). Affected systems, that have been provisioned with Create MyConfig (CMC), contain a Insertion of Sensitive Information into Log File vulnerability. This could allow a local authenticated user with low privileges to read sensitive information and thus circumvent access restrictions.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;&lt;strong&gt;Affected:&lt;/strong&gt; Siemens SINUMERIK 828D V4, Siemens SINUMERIK 840D sl V4, Siemens SINUMERIK ONE&lt;/p&gt;
&lt;p&gt;A vulnerability has been identified in SINUMERIK 828D V4 (All versions &amp;lt; V4.95 SP3), SINUMERIK 840D sl V4 (All versions &amp;lt; V4.95 SP3 in connection with using Create MyConfig (CMC) &amp;lt;= V4.8 SP1 HF6), SINUMERIK ONE (All versions &amp;lt; V6.23 in connection with using Create MyConfig (CMC) &amp;lt;= V6.6), SINUMERIK ONE (All versions &amp;lt; V6.15 SP4 in connection with using Create MyConfig (CMC) &amp;lt;= V6.6). Affected systems, that have been provisioned with Create MyConfig (CMC), contain a Insertion of Sensitive Information into Log File vulnerability. This could allow a local authenticated user with low privileges to read sensitive information and thus circumvent access restrictions.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/cve-2024-43781</guid>
    </item>
    <item>
      <title>ICSA-24-256-04 — Siemens SINUMERIK Systems</title>
      <link>https://cve.radiocsirt.org/vuln/icsa-24-256-04</link>
      <description>&lt;p&gt;Affected systems, that have been provisioned with Create MyConfig (CMC), contain a Insertion of Sensitive Information into Log File vulnerability. This could allow a local authenticated user with low privileges to read sensitive information and thus circumvent access restrictions.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Affected systems, that have been provisioned with Create MyConfig (CMC), contain a Insertion of Sensitive Information into Log File vulnerability. This could allow a local authenticated user with low privileges to read sensitive information and thus circumvent access restrictions.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsa-24-256-04</guid>
    </item>
  </channel>
</rss>