    <item>
      <title>CVE-2022-1368 — Cognex 3D-A1000 Dimensioning System Missing Authentication for Critical Function</title>
      <link>https://cve.radiocsirt.org/vuln/cve-2022-1368</link>
      <description>&lt;p&gt;&lt;strong&gt;Affected:&lt;/strong&gt; Cognex 3D-A1000 Dimensioning System&lt;/p&gt;
&lt;p&gt;The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;&lt;strong&gt;Affected:&lt;/strong&gt; Cognex 3D-A1000 Dimensioning System&lt;/p&gt;
&lt;p&gt;The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/cve-2022-1368</guid>
    </item>
    <item>
      <title>ICSA-22-249-03 — Cognex 3D-A1000 Dimensioning System</title>
      <link>https://cve.radiocsirt.org/vuln/icsa-22-249-03</link>
      <description>&lt;p&gt;The affected product allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.CVE-2022-1368 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The affected product allows an attacker to create false logs that show the password as having been changed when it is not, complicating forensics.CVE-2022-1522 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N). Attackers could bypass web access controls by inspecting and modifying the source code of password protected web elements.CVE-2022-1525 has been assigned to this vulnerability. A CVSS v3 base score of 9.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N).&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;The affected product allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.CVE-2022-1368 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The affected product allows an attacker to create false logs that show the password as having been changed when it is not, complicating forensics.CVE-2022-1522 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N). Attackers could bypass web access controls by inspecting and modifying the source code of password protected web elements.CVE-2022-1525 has been assigned to this vulnerability. A CVSS v3 base score of 9.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N).&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsa-22-249-03</guid>
    </item>