<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Sat, 03 Oct 2026 10:42:32 +0000</lastBuildDate>
    <item>
      <title>EUVD-2026-321390</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-321390</link>
      <description>EUVD-2026-321390</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-321390</guid>
    </item>
    <item>
      <title>fkie_cve-2026-8479</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2026-8479</link>
      <description>&lt;p&gt;IEC 60870-5-104 used in bidirectional mode in RTU500 is vulnerable
for a NULL pointer dereferencing, if a specially crafted
sequence of messages is sent for a certain time, causing
Denial of Service impact.
Product is only affected if IEC 60870-5-104 functionality in
bidirectional mode (BCI) is configured.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;IEC 60870-5-104 used in bidirectional mode in RTU500 is vulnerable
for a NULL pointer dereferencing, if a specially crafted
sequence of messages is sent for a certain time, causing
Denial of Service impact.
Product is only affected if IEC 60870-5-104 functionality in
bidirectional mode (BCI) is configured.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2026-8479</guid>
    </item>
    <item>
      <title>GHSA-m2rr-g8pf-8wrj</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-m2rr-g8pf-8wrj</link>
      <description>&lt;p&gt;IEC 60870-5-104 used in bidirectional mode is vulnerable
for a NULL pointer dereferencing, if a specially crafted
sequence of messages is sent for a certain time, causing
Denial of Service impact.
Product is only affected if IEC 60870-5-104 functionality in
bidirectional mode (BCI) is configured.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;IEC 60870-5-104 used in bidirectional mode is vulnerable
for a NULL pointer dereferencing, if a specially crafted
sequence of messages is sent for a certain time, causing
Denial of Service impact.
Product is only affected if IEC 60870-5-104 functionality in
bidirectional mode (BCI) is configured.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-m2rr-g8pf-8wrj</guid>
    </item>
    <item>
      <title>ICSA-26-155-04 — Hitachi Energy RTU500</title>
      <link>https://cve.radiocsirt.org/vuln/icsa-26-155-04</link>
      <description>&lt;p&gt;Hitachi Energy is aware of vulnerabilities that affect RTU500 product versions listed in this document. If exploited, these vulnerabilities primarily impact product availability, with potential secondary impacts on confidentiality and integrity. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Hitachi Energy is aware of vulnerabilities that affect RTU500 product versions listed in this document. If exploited, these vulnerabilities primarily impact product availability, with potential secondary impacts on confidentiality and integrity. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsa-26-155-04</guid>
    </item>
  </channel>
</rss>