<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Sat, 03 Oct 2026 02:22:16 +0000</lastBuildDate>
    <item>
      <title>EUVD-2026-364129</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-364129</link>
      <description>EUVD-2026-364129</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-364129</guid>
    </item>
    <item>
      <title>fkie_cve-2026-61884</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2026-61884</link>
      <description>&lt;p&gt;The Tycon Systems TPDIN-Monitor-WEB2
ships without HTTP credentials configured, intended for an installer to set them on first use. On firmware 2.4.4 and earlier, a unit left in this unconfigured state serves the web management interface without requiring any login. An attacker with network access to such a unit can reach full device controls, including power relay management, device reboot, remote access service configuration, and network settings, which could allow disruption of connected infrastructure or physical damage to equipment.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;The Tycon Systems TPDIN-Monitor-WEB2
ships without HTTP credentials configured, intended for an installer to set them on first use. On firmware 2.4.4 and earlier, a unit left in this unconfigured state serves the web management interface without requiring any login. An attacker with network access to such a unit can reach full device controls, including power relay management, device reboot, remote access service configuration, and network settings, which could allow disruption of connected infrastructure or physical damage to equipment.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2026-61884</guid>
    </item>
    <item>
      <title>GHSA-jmfc-m78f-w5vj</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-jmfc-m78f-w5vj</link>
      <description>&lt;p&gt;The web management interface of Tycon Systems TPDIN-Monitor-WEB2&lt;/p&gt;
&lt;p&gt;does not perform server-side validation of credentials during the login process. By submitting empty values for both credential fields, an unauthenticated remote attacker can bypass the authentication check and establish a valid administrative session. This grants full access to device controls including power relay management, device reboot, remote access service configuration, and network settings, which could allow an attacker to disrupt connected infrastructure or cause physical damage to equipment.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;The web management interface of Tycon Systems TPDIN-Monitor-WEB2&lt;/p&gt;
&lt;p&gt;does not perform server-side validation of credentials during the login process. By submitting empty values for both credential fields, an unauthenticated remote attacker can bypass the authentication check and establish a valid administrative session. This grants full access to device controls including power relay management, device reboot, remote access service configuration, and network settings, which could allow an attacker to disrupt connected infrastructure or cause physical damage to equipment.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-jmfc-m78f-w5vj</guid>
    </item>
    <item>
      <title>ICSA-26-202-01 — Tycon Systems TPDIN-Monitor-WEB2 (Update A)</title>
      <link>https://cve.radiocsirt.org/vuln/icsa-26-202-01</link>
      <description>&lt;p&gt;The device ships without HTTP credentials configured, intended for an installer to set them on first use. On firmware 2.4.4 and earlier, a unit left in this unconfigured state serves the web management interface without requiring any login. An attacker with network access to such a unit can reach full device controls, including power relay management, device reboot, remote access service configuration, and network settings, which could allow disruption of connected infrastructure or physical damage to equipment. The device&amp;#39;s web management interface stores and displays system credentials in cleartext on a certain configuration page accessible to authenticated users. Any party with access to the administrative dashboard can immediately read these credentials, which may be used to compromise other systems on the local network.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;The device ships without HTTP credentials configured, intended for an installer to set them on first use. On firmware 2.4.4 and earlier, a unit left in this unconfigured state serves the web management interface without requiring any login. An attacker with network access to such a unit can reach full device controls, including power relay management, device reboot, remote access service configuration, and network settings, which could allow disruption of connected infrastructure or physical damage to equipment. The device&amp;#39;s web management interface stores and displays system credentials in cleartext on a certain configuration page accessible to authenticated users. Any party with access to the administrative dashboard can immediately read these credentials, which may be used to compromise other systems on the local network.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsa-26-202-01</guid>
    </item>
  </channel>
</rss>
