      <title>2NGA003179 — ABB Protection and Control IED Manager (PCM600) - PCM600 Project Import Path Traversal</title>
      <link>https://cve.radiocsirt.org/vuln/2nga003179</link>
      <description>&lt;p&gt;ABB is aware of a privately reported vulnerability affecting the PCM600 project import functionality. An update is available that resolves this vulnerability in the affected product versions.&lt;/p&gt;
&lt;p&gt;A specially crafted PCM600 project archive may exploit insufficient validation of archive entry paths during project import. Successful exploitation could allow an attacker to create or overwrite files outside the intended extraction directory using the permissions of the importing user.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;ABB is aware of a privately reported vulnerability affecting the PCM600 project import functionality. An update is available that resolves this vulnerability in the affected product versions.&lt;/p&gt;
&lt;p&gt;A specially crafted PCM600 project archive may exploit insufficient validation of archive entry paths during project import. Successful exploitation could allow an attacker to create or overwrite files outside the intended extraction directory using the permissions of the importing user.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/2nga003179</guid>
    </item>
    <item>
      <title>EUVD-2026-377694</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-377694</link>
      <description>EUVD-2026-377694</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-377694</guid>
    </item>
    <item>
      <title>fkie_cve-2026-15953</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2026-15953</link>
      <description>&lt;p&gt;Improper Limitation of a Pathname to a Restricted Directory (&amp;#39;Path Traversal&amp;#39;) vulnerability in ABB Protection and control IED manager (PCM600).&lt;/p&gt;
&lt;p&gt;This issue affects Protection and control IED manager (PCM600): through 2.14.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Improper Limitation of a Pathname to a Restricted Directory (&amp;#39;Path Traversal&amp;#39;) vulnerability in ABB Protection and control IED manager (PCM600).&lt;/p&gt;
&lt;p&gt;This issue affects Protection and control IED manager (PCM600): through 2.14.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2026-15953</guid>
    </item>
    <item>
      <title>GHSA-469j-4qv8-mjfp</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-469j-4qv8-mjfp</link>
      <description>&lt;p&gt;Improper Limitation of a Pathname to a Restricted Directory (&amp;#39;Path Traversal&amp;#39;) vulnerability in ABB Protection and control IED manager (PCM600).&lt;/p&gt;
&lt;p&gt;This issue affects Protection and control IED manager (PCM600): through 2.14.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Improper Limitation of a Pathname to a Restricted Directory (&amp;#39;Path Traversal&amp;#39;) vulnerability in ABB Protection and control IED manager (PCM600).&lt;/p&gt;
&lt;p&gt;This issue affects Protection and control IED manager (PCM600): through 2.14.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-469j-4qv8-mjfp</guid>
    </item>
    <item>
      <title>ICSA-26-274-03 — ABB Protection and Control IED Manager PCM600</title>
      <link>https://cve.radiocsirt.org/vuln/icsa-26-274-03</link>
      <description>&lt;p&gt;A vulnerability exists in the Scheduler Service installed with PCM600. The service executes under the LocalSystem account while permissions are granted to standard PCM600 users through membership in the local users group. An attacker with local access and valid user credentials may exploit this vulnerability to elevate privileges and obtain control of the affected host. A vulnerability exists in the processing of PCM600 project archives files. Insufficient validation of archive entry paths may permit path traversal during extraction, potentially allowing files to be written to loca tions outside the intended extraction directory.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A vulnerability exists in the Scheduler Service installed with PCM600. The service executes under the LocalSystem account while permissions are granted to standard PCM600 users through membership in the local users group. An attacker with local access and valid user credentials may exploit this vulnerability to elevate privileges and obtain control of the affected host. A vulnerability exists in the processing of PCM600 project archives files. Insufficient validation of archive entry paths may permit path traversal during extraction, potentially allowing files to be written to loca tions outside the intended extraction directory.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsa-26-274-03</guid>
    </item>
  </channel>
</rss>