<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Mon, 12 Oct 2026 17:28:00 +0000</lastBuildDate>
    <item>
      <title>bdu:2025-15617</title>
      <link>https://cve.radiocsirt.org/vuln/bdu:2025-15617</link>
      <description>bdu:2025-15617</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/bdu:2025-15617</guid>
    </item>
    <item>
      <title>cnvd-2026-07563</title>
      <link>https://cve.radiocsirt.org/vuln/cnvd-2026-07563</link>
      <description>cnvd-2026-07563</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/cnvd-2026-07563</guid>
    </item>
    <item>
      <title>EUVD-2026-262915</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-262915</link>
      <description>EUVD-2026-262915</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-262915</guid>
    </item>
    <item>
      <title>fkie_cve-2025-40830</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2025-40830</link>
      <description>&lt;p&gt;A vulnerability has been identified in SINEC Security Monitor (All versions &amp;lt; V4.10.0). The affected application does not have proper authorization checks for the file_transfer feature in ssmctl-client command. This could allow an authenticated, lowly privileged local attacker to read or write to any file on server or sensor.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A vulnerability has been identified in SINEC Security Monitor (All versions &amp;lt; V4.10.0). The affected application does not have proper authorization checks for the file_transfer feature in ssmctl-client command. This could allow an authenticated, lowly privileged local attacker to read or write to any file on server or sensor.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2025-40830</guid>
    </item>
    <item>
      <title>GHSA-35cr-f3qc-gm6j</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-35cr-f3qc-gm6j</link>
      <description>&lt;p&gt;A vulnerability has been identified in SINEC Security Monitor (All versions &amp;lt; V4.10.0). The affected application does not have proper authorization checks for the file_transfer feature in ssmctl-client command. This could allow an authenticated, lowly privileged local attacker to read or write to any file on server or sensor.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A vulnerability has been identified in SINEC Security Monitor (All versions &amp;lt; V4.10.0). The affected application does not have proper authorization checks for the file_transfer feature in ssmctl-client command. This could allow an authenticated, lowly privileged local attacker to read or write to any file on server or sensor.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-35cr-f3qc-gm6j</guid>
    </item>
    <item>
      <title>ICSA-26-015-06 — Siemens SINEC Security Monitor</title>
      <link>https://cve.radiocsirt.org/vuln/icsa-26-015-06</link>
      <description>&lt;p&gt;The affected application does not have proper authorization checks for the file_transfer feature in ssmctl-client command. This could allow an authenticated, lowly privileged local attacker to read or write to any file on server or sensor. The affected application lacks input validation of date parameter in report generation functionality. This could allow an authenticated, lowly privileged attacker to cause denial of service condition of the report functionality.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;The affected application does not have proper authorization checks for the file_transfer feature in ssmctl-client command. This could allow an authenticated, lowly privileged local attacker to read or write to any file on server or sensor. The affected application lacks input validation of date parameter in report generation functionality. This could allow an authenticated, lowly privileged attacker to cause denial of service condition of the report functionality.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsa-26-015-06</guid>
    </item>
    <item>
      <title>SSA-882673 — SSA-882673: Multiple Vulnerabilities in SINEC Security Monitor before V4.10.0</title>
      <link>https://cve.radiocsirt.org/vuln/ssa-882673</link>
      <description>&lt;p&gt;The affected application does not have proper authorization checks for the file_transfer feature in ssmctl-client command. This could allow an authenticated, lowly privileged local attacker to read or write to any file on server or sensor. The affected application lacks input validation of date parameter in report generation functionality. This could allow an authenticated, lowly privileged attacker to cause denial of service condition of the report functionality.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;The affected application does not have proper authorization checks for the file_transfer feature in ssmctl-client command. This could allow an authenticated, lowly privileged local attacker to read or write to any file on server or sensor. The affected application lacks input validation of date parameter in report generation functionality. This could allow an authenticated, lowly privileged attacker to cause denial of service condition of the report functionality.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ssa-882673</guid>
    </item>
  </channel>
</rss>
