<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Thu, 08 Oct 2026 02:19:28 +0000</lastBuildDate>
    <item>
      <title>bdu:2025-02433</title>
      <link>https://cve.radiocsirt.org/vuln/bdu:2025-02433</link>
      <description>bdu:2025-02433</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/bdu:2025-02433</guid>
    </item>
    <item>
      <title>EUVD-2026-254066</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-254066</link>
      <description>EUVD-2026-254066</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-254066</guid>
    </item>
    <item>
      <title>fkie_cve-2024-13892</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2024-13892</link>
      <description>&lt;p&gt;Smartwares cameras CIP-37210AT and C724IP, as well as others which share the same firmware in versions up to 3.3.0, are vulnerable to command injection. 
During the initialization process, a user has to use a mobile app to provide devices with Access Point credentials. This input is not properly sanitized, what allows for command injection.
The vendor has not replied to reports, so the patching status remains unknown. Newer firmware versions might be vulnerable as well.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Smartwares cameras CIP-37210AT and C724IP, as well as others which share the same firmware in versions up to 3.3.0, are vulnerable to command injection. 
During the initialization process, a user has to use a mobile app to provide devices with Access Point credentials. This input is not properly sanitized, what allows for command injection.
The vendor has not replied to reports, so the patching status remains unknown. Newer firmware versions might be vulnerable as well.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2024-13892</guid>
    </item>
    <item>
      <title>GHSA-mcv4-fgfj-mggf</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-mcv4-fgfj-mggf</link>
      <description>&lt;p&gt;Smartwares cameras CIP-37210AT and C724IP, as well as others which share the same firmware in versions up to 3.3.0, are vulnerable to command injection. 
During the initialization process, a user has to use a mobile app to provide devices with Access Point credentials. This input is not properly sanitized, what allows for command injection.
The vendor has not replied to reports, so the patching status remains unknown. Newer firmware versions might be vulnerable as well.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Smartwares cameras CIP-37210AT and C724IP, as well as others which share the same firmware in versions up to 3.3.0, are vulnerable to command injection. 
During the initialization process, a user has to use a mobile app to provide devices with Access Point credentials. This input is not properly sanitized, what allows for command injection.
The vendor has not replied to reports, so the patching status remains unknown. Newer firmware versions might be vulnerable as well.&lt;/p&gt;</content:encoded>