    <item>
      <title>EUVD-2026-224742</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-224742</link>
      <description>EUVD-2026-224742</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-224742</guid>
    </item>
    <item>
      <title>fkie_cve-2024-11499</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2024-11499</link>
      <description>&lt;p&gt;A vulnerability exists in RTU500 IEC 60870-4-104 controlled station functionality, that allows an authenticated and authorized attacker to perform a CMU restart. The vulnerability can be triggered if certificates are updated while in use on active connections.&lt;/p&gt;
&lt;p&gt;The affected CMU will automatically recover itself if an attacker successfully exploits this vulnerability.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A vulnerability exists in RTU500 IEC 60870-4-104 controlled station functionality, that allows an authenticated and authorized attacker to perform a CMU restart. The vulnerability can be triggered if certificates are updated while in use on active connections.&lt;/p&gt;
&lt;p&gt;The affected CMU will automatically recover itself if an attacker successfully exploits this vulnerability.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2024-11499</guid>
    </item>
    <item>
      <title>GHSA-h77r-2p45-qp9h</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-h77r-2p45-qp9h</link>
      <description>&lt;p&gt;A vulnerability exists in RTU500 IEC 60870-4-104 controlled station functionality, that allows an authenticated and authorized attacker to perform a CMU restart. The vulnerability can be triggered if certificates are updated while in use on active connections.&lt;/p&gt;
&lt;p&gt;The affected CMU will automatically recover itself if an attacker successfully exploits this vulnerability.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A vulnerability exists in RTU500 IEC 60870-4-104 controlled station functionality, that allows an authenticated and authorized attacker to perform a CMU restart. The vulnerability can be triggered if certificates are updated while in use on active connections.&lt;/p&gt;
&lt;p&gt;The affected CMU will automatically recover itself if an attacker successfully exploits this vulnerability.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-h77r-2p45-qp9h</guid>
    </item>
    <item>
      <title>ICSA-25-093-01 — Hitachi Energy RTU500 Series (Update B)</title>
      <link>https://cve.radiocsirt.org/vuln/icsa-25-093-01</link>
      <description>&lt;p&gt;Hitachi Energy is aware of the vulnerabilities, CVE-2024-10037, CVE-2024-11499, CVE-2024-12169, and CVE-2025-1445 in the RTU500 Web server component, the IEC 60870-5-104 controlled station implementation and IEC 61850 implementation, that affects the RTU500 versions that are listed below. An attacker successfully exploiting these vulnerabilities could trigger a restart of a RTU500 CMU. Please refer to the Recom-mended Immediate Actions for information about the available mitigation/remediation strategies.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Hitachi Energy is aware of the vulnerabilities, CVE-2024-10037, CVE-2024-11499, CVE-2024-12169, and CVE-2025-1445 in the RTU500 Web server component, the IEC 60870-5-104 controlled station implementation and IEC 61850 implementation, that affects the RTU500 versions that are listed below. An attacker successfully exploiting these vulnerabilities could trigger a restart of a RTU500 CMU. Please refer to the Recom-mended Immediate Actions for information about the available mitigation/remediation strategies.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsa-25-093-01</guid>
    </item>
    <item>
      <title>WID-SEC-W-2025-0637 — Hitachi Energy RTU500: Mehrere Schwachstellen ermöglichen Denial of Service</title>
      <link>https://cve.radiocsirt.org/vuln/wid-sec-w-2025-0637</link>
      <description>&lt;p&gt;Ein entfernter, anonymer oder authentisierter Angreifer kann mehrere Schwachstellen in Hitachi Energy RTU500 ausnutzen, um einen Denial-of-Service-Zustand zu erzeugen.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Ein entfernter, anonymer oder authentisierter Angreifer kann mehrere Schwachstellen in Hitachi Energy RTU500 ausnutzen, um einen Denial-of-Service-Zustand zu erzeugen.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/wid-sec-w-2025-0637</guid>
    </item>