<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Fri, 02 Oct 2026 18:41:31 +0000</lastBuildDate>
    <item>
      <title>EUVD-2026-226267</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-226267</link>
      <description>EUVD-2026-226267</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-226267</guid>
    </item>
    <item>
      <title>fkie_cve-2024-10037</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2024-10037</link>
      <description>&lt;p&gt;A vulnerability exists in the RTU500 web server component that can cause a denial of service to the RTU500 CMU application if a specially crafted message sequence is executed on a WebSocket connection.
An attacker must be properly authenticated and the test mode function of RTU500 must be enabled to exploit this vulnerability.&lt;/p&gt;
&lt;p&gt;The affected CMU will automatically recover itself if an attacker successfully exploits this vulnerability.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A vulnerability exists in the RTU500 web server component that can cause a denial of service to the RTU500 CMU application if a specially crafted message sequence is executed on a WebSocket connection.
An attacker must be properly authenticated and the test mode function of RTU500 must be enabled to exploit this vulnerability.&lt;/p&gt;
&lt;p&gt;The affected CMU will automatically recover itself if an attacker successfully exploits this vulnerability.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2024-10037</guid>
    </item>
    <item>
      <title>GHSA-665f-p6v8-5227</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-665f-p6v8-5227</link>
      <description>&lt;p&gt;A vulnerability exists in the RTU500 web server component that can cause a denial of service to the RTU500 CMU application if a specially crafted message sequence is executed on a WebSocket connection.
An attacker must be properly authenticated and the test mode function of RTU500 must be enabled to exploit this vulnerability.&lt;/p&gt;
&lt;p&gt;The affected CMU will automatically recover itself if an attacker successfully exploits this vulnerability.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A vulnerability exists in the RTU500 web server component that can cause a denial of service to the RTU500 CMU application if a specially crafted message sequence is executed on a WebSocket connection.
An attacker must be properly authenticated and the test mode function of RTU500 must be enabled to exploit this vulnerability.&lt;/p&gt;
&lt;p&gt;The affected CMU will automatically recover itself if an attacker successfully exploits this vulnerability.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-665f-p6v8-5227</guid>
    </item>
    <item>
      <title>ICSA-25-093-01 — Hitachi Energy RTU500 Series (Update B)</title>
      <link>https://cve.radiocsirt.org/vuln/icsa-25-093-01</link>
      <description>&lt;p&gt;Hitachi Energy is aware of the vulnerabilities, CVE-2024-10037, CVE-2024-11499, CVE-2024-12169, and CVE-2025-1445 in the RTU500 Web server component, the IEC 60870-5-104 controlled station implementation and IEC 61850 implementation, that affects the RTU500 versions that are listed below. An attacker successfully exploiting these vulnerabilities could trigger a restart of a RTU500 CMU. Please refer to the Recom-mended Immediate Actions for information about the available mitigation/remediation strategies.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Hitachi Energy is aware of the vulnerabilities, CVE-2024-10037, CVE-2024-11499, CVE-2024-12169, and CVE-2025-1445 in the RTU500 Web server component, the IEC 60870-5-104 controlled station implementation and IEC 61850 implementation, that affects the RTU500 versions that are listed below. An attacker successfully exploiting these vulnerabilities could trigger a restart of a RTU500 CMU. Please refer to the Recom-mended Immediate Actions for information about the available mitigation/remediation strategies.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsa-25-093-01</guid>
    </item>
    <item>
      <title>WID-SEC-W-2025-0637 — Hitachi Energy RTU500: Mehrere Schwachstellen ermöglichen Denial of Service</title>
      <link>https://cve.radiocsirt.org/vuln/wid-sec-w-2025-0637</link>
      <description>&lt;p&gt;Ein entfernter, anonymer oder authentisierter Angreifer kann mehrere Schwachstellen in Hitachi Energy RTU500 ausnutzen, um einen Denial-of-Service-Zustand zu erzeugen.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Ein entfernter, anonymer oder authentisierter Angreifer kann mehrere Schwachstellen in Hitachi Energy RTU500 ausnutzen, um einen Denial-of-Service-Zustand zu erzeugen.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/wid-sec-w-2025-0637</guid>
    </item>
  </channel>
</rss>
