<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Sun, 04 Oct 2026 02:42:59 +0000</lastBuildDate>
    <item>
      <title>bdu:2023-03556</title>
      <link>https://cve.radiocsirt.org/vuln/bdu:2023-03556</link>
      <description>bdu:2023-03556</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/bdu:2023-03556</guid>
    </item>
    <item>
      <title>EUVD-2026-204665</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-204665</link>
      <description>EUVD-2026-204665</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-204665</guid>
    </item>
    <item>
      <title>fkie_cve-2023-31222</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2023-31222</link>
      <description>&lt;p&gt;Deserialization of untrusted data in Microsoft Messaging Queuing Service in Medtronic&amp;#39;s Paceart Optima versions 1.11 and earlier on Windows allows an unauthorized user to impact a healthcare delivery organization’s Paceart Optima system cardiac device causing data to be deleted, stolen, or modified, or the Paceart Optima system being used for further network penetration via network connectivity.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Deserialization of untrusted data in Microsoft Messaging Queuing Service in Medtronic&amp;#39;s Paceart Optima versions 1.11 and earlier on Windows allows an unauthorized user to impact a healthcare delivery organization’s Paceart Optima system cardiac device causing data to be deleted, stolen, or modified, or the Paceart Optima system being used for further network penetration via network connectivity.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2023-31222</guid>
    </item>
    <item>
      <title>GHSA-g4h4-ww84-r75w</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-g4h4-ww84-r75w</link>
      <description>&lt;p&gt;Deserialization of untrusted data in Microsoft Messaging Queuing Service in Medtronic&amp;#39;s Paceart Optima versions 1.11 and earlier on Windows allows an unauthorized user to impact a healthcare delivery organization’s Paceart Optima system cardiac device causing data to be deleted, stolen, or modified, or the Paceart Optima system being used for further network penetration via network connectivity.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Deserialization of untrusted data in Microsoft Messaging Queuing Service in Medtronic&amp;#39;s Paceart Optima versions 1.11 and earlier on Windows allows an unauthorized user to impact a healthcare delivery organization’s Paceart Optima system cardiac device causing data to be deleted, stolen, or modified, or the Paceart Optima system being used for further network penetration via network connectivity.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-g4h4-ww84-r75w</guid>
    </item>
    <item>
      <title>gsd-2023-31222</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2023-31222</link>
      <description>gsd-2023-31222</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2023-31222</guid>
    </item>
    <item>
      <title>ICSMA-23-180-01 — Medtronic Paceart Optima System</title>
      <link>https://cve.radiocsirt.org/vuln/icsma-23-180-01</link>
      <description>&lt;p&gt;If a healthcare delivery organization has enabled the optional Paceart Messaging Service in the Paceart Optima system, an unauthorized user could exploit this vulnerability to perform remote code execution and/or denial-of-service (DoS) attacks by sending specially crafted messages to the Paceart Optima system. Remote code execution could result in the deletion, theft, or modification of Paceart Optima system&amp;#39;s cardiac device data, or use of the Paceart Optima system for further network penetration. A DoS attack could cause the Paceart Optima system to slow or be unresponsive.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;If a healthcare delivery organization has enabled the optional Paceart Messaging Service in the Paceart Optima system, an unauthorized user could exploit this vulnerability to perform remote code execution and/or denial-of-service (DoS) attacks by sending specially crafted messages to the Paceart Optima system. Remote code execution could result in the deletion, theft, or modification of Paceart Optima system&amp;#39;s cardiac device data, or use of the Paceart Optima system for further network penetration. A DoS attack could cause the Paceart Optima system to slow or be unresponsive.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsma-23-180-01</guid>
    </item>
  </channel>
</rss>