<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Sat, 03 Oct 2026 07:44:25 +0000</lastBuildDate>
    <item>
      <title>bdu:2024-09114</title>
      <link>https://cve.radiocsirt.org/vuln/bdu:2024-09114</link>
      <description>bdu:2024-09114</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/bdu:2024-09114</guid>
    </item>
    <item>
      <title>certfr-2024-avi-0757 — De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un atta…</title>
      <link>https://cve.radiocsirt.org/vuln/certfr-2024-avi-0757</link>
      <description>certfr-2024-avi-0757</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/certfr-2024-avi-0757</guid>
    </item>
    <item>
      <title>cnvd-2024-38017</title>
      <link>https://cve.radiocsirt.org/vuln/cnvd-2024-38017</link>
      <description>cnvd-2024-38017</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/cnvd-2024-38017</guid>
    </item>
    <item>
      <title>EUVD-2026-162306</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-162306</link>
      <description>EUVD-2026-162306</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-162306</guid>
    </item>
    <item>
      <title>fkie_cve-2023-28827</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2023-28827</link>
      <description>&lt;p&gt;A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions &amp;lt; V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions &amp;lt; V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions &amp;lt; V3.5.20), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions &amp;lt; V3.5.20), SIMATIC CP 1243-7 LTE (All versions &amp;lt; V3.5.20), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions &amp;lt; V3.5.20), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC WinCC Runtime Advanced (All versions), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions &amp;lt; V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions &amp;lt; V2.4.8). The web server of the affected devices do not properly handle certain requests, causing a timeout in the watchdog, which could lead to the clean up of pointers. &#13;
&#13;
This could allow a remote attacker to cause a denial of service condition in the system.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions &amp;lt; V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions &amp;lt; V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions &amp;lt; V3.5.20), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions &amp;lt; V3.5.20), SIMATIC CP 1243-7 LTE (All versions &amp;lt; V3.5.20), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions &amp;lt; V3.5.20), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC WinCC Runtime Advanced (All versions), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions &amp;lt; V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions &amp;lt; V2.4.8). The web server of the affected devices do not properly handle certain requests, causing a timeout in the watchdog, which could lead to the clean up of pointers. &#13;
&#13;
This could allow a remote attacker to cause a denial of service condition in the system.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2023-28827</guid>
    </item>
    <item>
      <title>GHSA-wh3c-3qmr-4ghp</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-wh3c-3qmr-4ghp</link>
      <description>&lt;p&gt;A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions &amp;lt; V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions &amp;lt; V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions &amp;lt; V3.5.20), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions &amp;lt; V3.5.20), SIMATIC CP 1243-7 LTE (All versions &amp;lt; V3.5.20), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions &amp;lt; V3.5.20), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC WinCC Runtime Advanced (All versions), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions &amp;lt; V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions &amp;lt; V2.4.8). The web server of the affected devices do not properly handle certain requests, causing a timeout in the watchdog, which could lead to the clean up of pointers.&lt;/p&gt;
&lt;p&gt;This could allow a remote attacker to cause a denial of service condition in the system.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions &amp;lt; V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions &amp;lt; V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions &amp;lt; V3.5.20), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions &amp;lt; V3.5.20), SIMATIC CP 1243-7 LTE (All versions &amp;lt; V3.5.20), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions &amp;lt; V3.5.20), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC WinCC Runtime Advanced (All versions), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions &amp;lt; V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions &amp;lt; V2.4.8). The web server of the affected devices do not properly handle certain requests, causing a timeout in the watchdog, which could lead to the clean up of pointers.&lt;/p&gt;
&lt;p&gt;This could allow a remote attacker to cause a denial of service condition in the system.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-wh3c-3qmr-4ghp</guid>
    </item>
    <item>
      <title>gsd-2023-28827</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2023-28827</link>
      <description>gsd-2023-28827</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2023-28827</guid>
    </item>
    <item>
      <title>ICSA-24-256-09 — Siemens SIMATIC, SIPLUS, and TIM</title>
      <link>https://cve.radiocsirt.org/vuln/icsa-24-256-09</link>
      <description>&lt;p&gt;The web server of the affected devices do not properly handle certain requests, causing a timeout in the watchdog, which could lead to the clean up of pointers. &#13;
&#13;
This could allow a remote attacker to cause a denial of service condition in the system. The web server of the affected devices do not properly handle the shutdown or reboot request, which could lead to the clean up of certain resources. &#13;
&#13;
This could allow a remote attacker with elevated privileges to cause a denial of service condition in the system. The web server of the affected devices do not properly handle certain errors when using the Expect HTTP request header, resulting in NULL dereference.&#13;
&#13;
This could allow a remote attacker with no privileges to cause a denial of service condition in the system.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;The web server of the affected devices do not properly handle certain requests, causing a timeout in the watchdog, which could lead to the clean up of pointers. &#13;
&#13;
This could allow a remote attacker to cause a denial of service condition in the system. The web server of the affected devices do not properly handle the shutdown or reboot request, which could lead to the clean up of certain resources. &#13;
&#13;
This could allow a remote attacker with elevated privileges to cause a denial of service condition in the system. The web server of the affected devices do not properly handle certain errors when using the Expect HTTP request header, resulting in NULL dereference.&#13;
&#13;
This could allow a remote attacker with no privileges to cause a denial of service condition in the system.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsa-24-256-09</guid>
    </item>
    <item>
      <title>WID-SEC-W-2024-2091 — Siemens SIMATIC WinCC: Mehrere Schwachstellen ermöglichen Denial of Service</title>
      <link>https://cve.radiocsirt.org/vuln/wid-sec-w-2024-2091</link>
      <description>&lt;p&gt;Ein entfernter, anonymer Angreifer kann mehrere Schwachstellen in Siemens SIMATIC WinCC ausnutzen, um einen Denial of Service Angriff durchzuführen.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Ein entfernter, anonymer Angreifer kann mehrere Schwachstellen in Siemens SIMATIC WinCC ausnutzen, um einen Denial of Service Angriff durchzuführen.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/wid-sec-w-2024-2091</guid>
    </item>
  </channel>
</rss>