<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Sat, 03 Oct 2026 22:47:54 +0000</lastBuildDate>
    <item>
      <title>EUVD-2026-209908</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-209908</link>
      <description>EUVD-2026-209908</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-209908</guid>
    </item>
    <item>
      <title>fkie_cve-2023-28399</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2023-28399</link>
      <description>&lt;p&gt;Incorrect permission assignment for critical resource exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. ACL (Access Control List) is not appropriately set to the local folder where the affected product is installed, therefore a wide range of privileges is permitted to a user of the PC where the affected product is installed. As a result, the user may be able to destroy the system and/or execute a malicious program.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Incorrect permission assignment for critical resource exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. ACL (Access Control List) is not appropriately set to the local folder where the affected product is installed, therefore a wide range of privileges is permitted to a user of the PC where the affected product is installed. As a result, the user may be able to destroy the system and/or execute a malicious program.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2023-28399</guid>
    </item>
    <item>
      <title>GHSA-vwgg-32x4-wm56</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-vwgg-32x4-wm56</link>
      <description>&lt;p&gt;Incorrect permission assignment for critical resource exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. ACL (Access Control List) is not appropriately set to the local folder where the affected product is installed, therefore a wide range of privileges is permitted to a user of the PC where the affected product is installed. As a result, the user may be able to destroy the system and/or execute a malicious program.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Incorrect permission assignment for critical resource exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. ACL (Access Control List) is not appropriately set to the local folder where the affected product is installed, therefore a wide range of privileges is permitted to a user of the PC where the affected product is installed. As a result, the user may be able to destroy the system and/or execute a malicious program.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-vwgg-32x4-wm56</guid>
    </item>
    <item>
      <title>gsd-2023-28399</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2023-28399</link>
      <description>gsd-2023-28399</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2023-28399</guid>
    </item>
    <item>
      <title>jvndb-2023-002002</title>
      <link>https://cve.radiocsirt.org/vuln/jvndb-2023-002002</link>
      <description>&lt;p&gt;CONPROSYS HMI System (CHS) provided by Contec Co., Ltd. contains multiple vulnerabilities listed below.&#13;
&#13;
* Plaintext storage of a password (CWE-256) - CVE-2023-28713&#13;
* Incorrect permission assignment for critical resource (CWE-732) - CVE-2023-28399&#13;
* Improper access control (CWE-284) - CVE-2023-28657&#13;
* Cross-site scripting (CWE-79) - CVE-2023-28651&#13;
* Server-side request forgery (CWE-918)- CVE-2023-28824&#13;
* SQL injection (CWE-89) - CVE-2023-29154&#13;
* Improper control of interaction frequency (CWE-799) - CVE-2023-2758&#13;
&#13;
Michael Heinzl reported the vulnerabilities listed below to JPCERT/CC, and JPCERT/CC coordinated with the developer.&#13;
CVE-2023-28713, CVE-2023-28399, CVE-2023-28657, CVE-2023-28651, CVE-2023-28824, CVE-2023-29154&#13;
&#13;
Tenable, Inc. reported CVE-2023-2758 vulnerability to the developer, and based on the coordination request made by the developer, JPCERT/CC coordinated with Tenable, Inc. and the developer.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;CONPROSYS HMI System (CHS) provided by Contec Co., Ltd. contains multiple vulnerabilities listed below.&#13;
&#13;
* Plaintext storage of a password (CWE-256) - CVE-2023-28713&#13;
* Incorrect permission assignment for critical resource (CWE-732) - CVE-2023-28399&#13;
* Improper access control (CWE-284) - CVE-2023-28657&#13;
* Cross-site scripting (CWE-79) - CVE-2023-28651&#13;
* Server-side request forgery (CWE-918)- CVE-2023-28824&#13;
* SQL injection (CWE-89) - CVE-2023-29154&#13;
* Improper control of interaction frequency (CWE-799) - CVE-2023-2758&#13;
&#13;
Michael Heinzl reported the vulnerabilities listed below to JPCERT/CC, and JPCERT/CC coordinated with the developer.&#13;
CVE-2023-28713, CVE-2023-28399, CVE-2023-28657, CVE-2023-28651, CVE-2023-28824, CVE-2023-29154&#13;
&#13;
Tenable, Inc. reported CVE-2023-2758 vulnerability to the developer, and based on the coordination request made by the developer, JPCERT/CC coordinated with Tenable, Inc. and the developer.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/jvndb-2023-002002</guid>
    </item>
  </channel>
</rss>
