<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Fri, 02 Oct 2026 11:32:36 +0000</lastBuildDate>
    <item>
      <title>EUVD-2026-219487</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-219487</link>
      <description>EUVD-2026-219487</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-219487</guid>
    </item>
    <item>
      <title>fkie_cve-2023-0888</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2023-0888</link>
      <description>&lt;p&gt;An improper neutralization of directives in dynamically evaluated code vulnerability in the WiFi Battery embedded web server in versions L90/U70 and L92/U92 can be used to gain administrative access to the WiFi communication module. An authenticated user, having access to both the medical device WiFi network (such as a biomedical engineering staff member) and the specific B.Braun Battery Pack SP with WiFi web server credentials, could get administrative (root) access on the infusion pump communication module. This could be used as a vector to start further attacks&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;An improper neutralization of directives in dynamically evaluated code vulnerability in the WiFi Battery embedded web server in versions L90/U70 and L92/U92 can be used to gain administrative access to the WiFi communication module. An authenticated user, having access to both the medical device WiFi network (such as a biomedical engineering staff member) and the specific B.Braun Battery Pack SP with WiFi web server credentials, could get administrative (root) access on the infusion pump communication module. This could be used as a vector to start further attacks&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2023-0888</guid>
    </item>
    <item>
      <title>GHSA-9w87-qf4h-4fc6</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-9w87-qf4h-4fc6</link>
      <description>&lt;p&gt;An improper neutralization of directives in dynamically evaluated code vulnerability in the WiFi Battery embedded web server in versions L90/U70 and L92/U92 can be used to gain administrative access to the WiFi communication module. An authenticated user, having access to both the medical device WiFi network (such as a biomedical engineering staff member) and the specific B.Braun Battery Pack SP with WiFi web server credentials, could get administrative (root) access on the infusion pump communication module. This could be used as a vector to start further attacks&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;An improper neutralization of directives in dynamically evaluated code vulnerability in the WiFi Battery embedded web server in versions L90/U70 and L92/U92 can be used to gain administrative access to the WiFi communication module. An authenticated user, having access to both the medical device WiFi network (such as a biomedical engineering staff member) and the specific B.Braun Battery Pack SP with WiFi web server credentials, could get administrative (root) access on the infusion pump communication module. This could be used as a vector to start further attacks&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-9w87-qf4h-4fc6</guid>
    </item>
    <item>
      <title>gsd-2023-0888</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2023-0888</link>
      <description>gsd-2023-0888</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2023-0888</guid>
    </item>
    <item>
      <title>ICSMA-23-103-01 — B. Braun Battery Pack SP with Wi-Fi</title>
      <link>https://cve.radiocsirt.org/vuln/icsma-23-103-01</link>
      <description>&lt;p&gt;An improper neutralization of directives in dynamically evaluated code vulnerability in the Wi-Fi Battery embedded web server versions L90/U70 and L92/U92 can be used to gain administrative access to the Wi-Fi communication module. An authenticated user, having access to both the medical device Wi-Fi network (such as a biomedical engineering staff member) and the specific B. Braun Battery Pack SP with Wi-Fi web server credentials, could gain administrative (root) access on the infusion pump communication module. This could be used as a vector to launch further attacks. CVE-2023-0888 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:L).&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;An improper neutralization of directives in dynamically evaluated code vulnerability in the Wi-Fi Battery embedded web server versions L90/U70 and L92/U92 can be used to gain administrative access to the Wi-Fi communication module. An authenticated user, having access to both the medical device Wi-Fi network (such as a biomedical engineering staff member) and the specific B. Braun Battery Pack SP with Wi-Fi web server credentials, could gain administrative (root) access on the infusion pump communication module. This could be used as a vector to launch further attacks. CVE-2023-0888 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:L).&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsma-23-103-01</guid>
    </item>
  </channel>
</rss>
