    <item>
      <title>bdu:2023-00228</title>
      <link>https://cve.radiocsirt.org/vuln/bdu:2023-00228</link>
      <description>bdu:2023-00228</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/bdu:2023-00228</guid>
    </item>
    <item>
      <title>certfr-2023-avi-0014 — De multiples vulnérabilités ont été découvertes dans les produits
Schneider Electric. Certaines d'entre elles permetten…</title>
      <link>https://cve.radiocsirt.org/vuln/certfr-2023-avi-0014</link>
      <description>certfr-2023-avi-0014</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/certfr-2023-avi-0014</guid>
    </item>
    <item>
      <title>EUVD-2026-322770</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-322770</link>
      <description>EUVD-2026-322770</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-322770</guid>
    </item>
    <item>
      <title>fkie_cve-2022-45788</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2022-45788</link>
      <description>&lt;p&gt;A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality &amp;amp; integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions), Modicon Momentum Unity M1E Processor - 171CBU* (All Versions), Modicon MC80 - BMKC80 (All Versions), Legacy Modicon Quantum - 140CPU65* and Premium CPUs - TSXP57* (All Versions)&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality &amp;amp; integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions), Modicon Momentum Unity M1E Processor - 171CBU* (All Versions), Modicon MC80 - BMKC80 (All Versions), Legacy Modicon Quantum - 140CPU65* and Premium CPUs - TSXP57* (All Versions)&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2022-45788</guid>
    </item>
    <item>
      <title>GHSA-7q3m-cm45-5qq5</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-7q3m-cm45-5qq5</link>
      <description>&lt;p&gt;A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality &amp;amp; integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure™ Control Expert (All Versions), EcoStruxure™ Process Expert (Version V2020 &amp;amp; prior), Modicon M340 CPU (part numbers BMXP34*) (All Versions), Modicon M580 CPU (part numbers BMEP* and BMEH*) (All Versions), Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) (All Versions), Modicon Momentum Unity M1E Processor (171CBU*) (All Versions), Modicon MC80 (BMKC80) (All Versions), Legacy Modicon Quantum (140CPU65*) and Premium CPUs (TSXP57*) (All Versions)&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality &amp;amp; integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure™ Control Expert (All Versions), EcoStruxure™ Process Expert (Version V2020 &amp;amp; prior), Modicon M340 CPU (part numbers BMXP34*) (All Versions), Modicon M580 CPU (part numbers BMEP* and BMEH*) (All Versions), Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) (All Versions), Modicon Momentum Unity M1E Processor (171CBU*) (All Versions), Modicon MC80 (BMKC80) (All Versions), Legacy Modicon Quantum (140CPU65*) and Premium CPUs (TSXP57*) (All Versions)&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-7q3m-cm45-5qq5</guid>
    </item>
    <item>
      <title>gsd-2022-45788</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2022-45788</link>
      <description>gsd-2022-45788</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2022-45788</guid>
    </item>
    <item>
      <title>ICSA-23-201-01 — Schneider Electric EcoStruxure Products, Modicon PLCs, and Programmable Automation Controllers</title>
      <link>https://cve.radiocsirt.org/vuln/icsa-23-201-01</link>
      <description>&lt;p&gt;The affected components contain a vulnerability that could cause arbitrary code execution, a denial-of-service condition, and loss of confidentiality &amp;amp; integrity when a malicious project file is loaded onto the controller.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;The affected components contain a vulnerability that could cause arbitrary code execution, a denial-of-service condition, and loss of confidentiality &amp;amp; integrity when a malicious project file is loaded onto the controller.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsa-23-201-01</guid>
    </item>
    <item>
      <title>SEVD-2023-010-05 — EcoStruxure™ Control Expert, EcoStruxure™ Process Expert and Modicon PLCs (Programmable Logic Controllers) and PACs (Pr…</title>
      <link>https://cve.radiocsirt.org/vuln/sevd-2023-010-05</link>
      <description>&lt;p&gt;Schneider Electric is aware of multiple vulnerabilities in its EcoStruxure™ Control Expert , EcoStruxure™ Process Expert and Modicon PLCs (Programmable Logic Controllers) and PACs (Programmable Automation Controllers).
Modicon PLCs (Programmable Logic Controllers) and PACs (Programmable Automation Controllers) control and monitor industrial operations in a sustainable, flexible, efficient, and protected way.
EcoStruxure™ Control Expert is the common programming, debugging and operating software for Modicon PLCs (Programmable Logic Controllers) and PACs (Programmable Automation Controllers).
The EcoStruxure™ Process Expert DCS is a single automation system to engineer, operate, and maintain your entire infrastructure for a sustainable, productive and market-agile plant.
Failure to apply the mitigations provided below may risk unauthorized access to your PLC, which could result in the possibility of denial of service and loss of confidentiality, integrity of the controller.
March 2023 Update: Remediation for EcoStruxure™ Control Expert, Modicon M580 CPU, and Momentum Unity M1E Processor are available for download (page 2). Additional mitigations for Modicon M340 were added.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Schneider Electric is aware of multiple vulnerabilities in its EcoStruxure™ Control Expert , EcoStruxure™ Process Expert and Modicon PLCs (Programmable Logic Controllers) and PACs (Programmable Automation Controllers).
Modicon PLCs (Programmable Logic Controllers) and PACs (Programmable Automation Controllers) control and monitor industrial operations in a sustainable, flexible, efficient, and protected way.
EcoStruxure™ Control Expert is the common programming, debugging and operating software for Modicon PLCs (Programmable Logic Controllers) and PACs (Programmable Automation Controllers).
The EcoStruxure™ Process Expert DCS is a single automation system to engineer, operate, and maintain your entire infrastructure for a sustainable, productive and market-agile plant.
Failure to apply the mitigations provided below may risk unauthorized access to your PLC, which could result in the possibility of denial of service and loss of confidentiality, integrity of the controller.
March 2023 Update: Remediation for EcoStruxure™ Control Expert, Modicon M580 CPU, and Momentum Unity M1E Processor are available for download (page 2). Additional mitigations for Modicon M340 were added.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/sevd-2023-010-05</guid>