<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Sat, 03 Oct 2026 07:40:58 +0000</lastBuildDate>
    <item>
      <title>bdu:2023-01596</title>
      <link>https://cve.radiocsirt.org/vuln/bdu:2023-01596</link>
      <description>bdu:2023-01596</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/bdu:2023-01596</guid>
    </item>
    <item>
      <title>certfr-2022-avi-896 — De multiples vulnérabilités ont été découvertes dans les produits
Schneider Electric. Certaines d'entre elles permetten…</title>
      <link>https://cve.radiocsirt.org/vuln/certfr-2022-avi-896</link>
      <description>certfr-2022-avi-896</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/certfr-2022-avi-896</guid>
    </item>
    <item>
      <title>EUVD-2026-236634</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-236634</link>
      <description>EUVD-2026-236634</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-236634</guid>
    </item>
    <item>
      <title>fkie_cve-2022-41669</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2022-41669</link>
      <description>&lt;p&gt;A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists in the SGIUtility component that allows adversaries with local user privileges to load a malicious DLL which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior).&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists in the SGIUtility component that allows adversaries with local user privileges to load a malicious DLL which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior).&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2022-41669</guid>
    </item>
    <item>
      <title>GHSA-cvcq-mw35-q882</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-cvcq-mw35-q882</link>
      <description>&lt;p&gt;A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists in the SGIUtility component that allows adversaries with local user privileges to load a malicious DLL which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior).&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists in the SGIUtility component that allows adversaries with local user privileges to load a malicious DLL which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior).&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-cvcq-mw35-q882</guid>
    </item>
    <item>
      <title>gsd-2022-41669</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2022-41669</link>
      <description>gsd-2022-41669</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2022-41669</guid>
    </item>
    <item>
      <title>SEVD-2022-284-01 — EcoStruxure™ Operator Terminal Expert and Pro-face BLUE</title>
      <link>https://cve.radiocsirt.org/vuln/sevd-2022-284-01</link>
      <description>&lt;p&gt;Schneider Electric is aware of multiple vulnerabilities in its EcoStruxure™ Operator Terminal Expert and Pro-face BLUE products.&#13;
The EcoStruxure™ Operator Terminal Expert and Pro-face BLUE products are HMI configuration software supporting gestures and UI designs.&#13;
Failure to apply the remediations provided below may risk unauthorized code execution by a local user of the Windows engineering workstation, which could result in loss of availability, integrity, and confidentiality of the workstation where EcoStruxure™ Operator Terminal Expert or Pro-face BLUE runtime is installed.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Schneider Electric is aware of multiple vulnerabilities in its EcoStruxure™ Operator Terminal Expert and Pro-face BLUE products.&#13;
The EcoStruxure™ Operator Terminal Expert and Pro-face BLUE products are HMI configuration software supporting gestures and UI designs.&#13;
Failure to apply the remediations provided below may risk unauthorized code execution by a local user of the Windows engineering workstation, which could result in loss of availability, integrity, and confidentiality of the workstation where EcoStruxure™ Operator Terminal Expert or Pro-face BLUE runtime is installed.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/sevd-2022-284-01</guid>
    </item>
  </channel>
</rss>
