<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Mon, 05 Oct 2026 15:37:33 +0000</lastBuildDate>
    <item>
      <title>bdu:2022-04408</title>
      <link>https://cve.radiocsirt.org/vuln/bdu:2022-04408</link>
      <description>bdu:2022-04408</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/bdu:2022-04408</guid>
    </item>
    <item>
      <title>certfr-2022-avi-628 — De multiples vulnérabilités ont été découvertes dans les produits
Schneider Electric. Certaines d'entre elles permetten…</title>
      <link>https://cve.radiocsirt.org/vuln/certfr-2022-avi-628</link>
      <description>certfr-2022-avi-628</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/certfr-2022-avi-628</guid>
    </item>
    <item>
      <title>EUVD-2026-185177</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-185177</link>
      <description>EUVD-2026-185177</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-185177</guid>
    </item>
    <item>
      <title>fkie_cve-2022-34756</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2022-34756</link>
      <description>&lt;p&gt;A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution or the crash of HTTPs stack which is used for the device Web HMI. Affected Products: Easergy P5 (V01.401.102 and prior)&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution or the crash of HTTPs stack which is used for the device Web HMI. Affected Products: Easergy P5 (V01.401.102 and prior)&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2022-34756</guid>
    </item>
    <item>
      <title>GHSA-8995-37xw-9hjj</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-8995-37xw-9hjj</link>
      <description>&lt;p&gt;A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution or the crash of HTTPs stack which is used for the device Web HMI. Affected Products: Easergy P5 (V01.401.102 and prior)&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution or the crash of HTTPs stack which is used for the device Web HMI. Affected Products: Easergy P5 (V01.401.102 and prior)&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-8995-37xw-9hjj</guid>
    </item>
    <item>
      <title>gsd-2022-34756</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2022-34756</link>
      <description>gsd-2022-34756</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2022-34756</guid>
    </item>
    <item>
      <title>SEVD-2022-193-04 — Easergy P5</title>
      <link>https://cve.radiocsirt.org/vuln/sevd-2022-193-04</link>
      <description>&lt;p&gt;Schneider Electric is aware of multiple vulnerabilities in its Easergy P5 product line.&#13;
The Easergy P5 is a medium voltage protection relay.&#13;
Failure to apply the mitigations or remediations provided below may risk disclosure of the device’s credentials, denial of service, device reboot, or an attacker could gain full control of the relay. This could result in loss of protection of your electrical network.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Schneider Electric is aware of multiple vulnerabilities in its Easergy P5 product line.&#13;
The Easergy P5 is a medium voltage protection relay.&#13;
Failure to apply the mitigations or remediations provided below may risk disclosure of the device’s credentials, denial of service, device reboot, or an attacker could gain full control of the relay. This could result in loss of protection of your electrical network.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/sevd-2022-193-04</guid>
    </item>
  </channel>
</rss>
