<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Fri, 02 Oct 2026 23:31:27 +0000</lastBuildDate>
    <item>
      <title>bdu:2022-02453</title>
      <link>https://cve.radiocsirt.org/vuln/bdu:2022-02453</link>
      <description>bdu:2022-02453</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/bdu:2022-02453</guid>
    </item>
    <item>
      <title>certfr-2022-avi-123 — De multiples vulnérabilités ont été découvertes dans les produits
Schneider. Elles permettent à un attaquant de provoqu…</title>
      <link>https://cve.radiocsirt.org/vuln/certfr-2022-avi-123</link>
      <description>certfr-2022-avi-123</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/certfr-2022-avi-123</guid>
    </item>
    <item>
      <title>cnvd-2022-13066</title>
      <link>https://cve.radiocsirt.org/vuln/cnvd-2022-13066</link>
      <description>cnvd-2022-13066</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/cnvd-2022-13066</guid>
    </item>
    <item>
      <title>EUVD-2026-14151</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-14151</link>
      <description>EUVD-2026-14151</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-14151</guid>
    </item>
    <item>
      <title>fkie_cve-2022-24310</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2022-24310</link>
      <description>&lt;p&gt;A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2022-24310</guid>
    </item>
    <item>
      <title>GHSA-f5c3-fr66-f3j2</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-f5c3-fr66-f3j2</link>
      <description>&lt;p&gt;A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-f5c3-fr66-f3j2</guid>
    </item>
    <item>
      <title>gsd-2022-24310</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2022-24310</link>
      <description>gsd-2022-24310</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2022-24310</guid>
    </item>
    <item>
      <title>ICSA-22-046-01 — Schneider Electric IGSS</title>
      <link>https://cve.radiocsirt.org/vuln/icsa-22-046-01</link>
      <description>&lt;p&gt;A vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages.CVE-2022-24310 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A vulnerability exists that could cause modification of an existing file by inserting data at the beginning of the file or creating a new file in the context of the data server. This could potentially lead to remote code execution when an attacker sends a specially crafted message.CVE-2022-24311 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A vulnerability exists that could cause modification of an existing file by adding data at the end of the file or creating a new file in the context of the data server. This could potentially lead to remote code execution when an attacker sends a specially crafted message.CVE-2022-24312 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message.CVE-2022-24313 has been assigned to this vulnerability. A CVSS v3 base sco…&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages.CVE-2022-24310 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A vulnerability exists that could cause modification of an existing file by inserting data at the beginning of the file or creating a new file in the context of the data server. This could potentially lead to remote code execution when an attacker sends a specially crafted message.CVE-2022-24311 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A vulnerability exists that could cause modification of an existing file by adding data at the end of the file or creating a new file in the context of the data server. This could potentially lead to remote code execution when an attacker sends a specially crafted message.CVE-2022-24312 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message.CVE-2022-24313 has been assigned to this vulnerability. A CVSS v3 base sco…&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsa-22-046-01</guid>
    </item>
    <item>
      <title>SEVD-2022-039-01 — IGSS (Interactive Graphical SCADA System)</title>
      <link>https://cve.radiocsirt.org/vuln/sevd-2022-039-01</link>
      <description>&lt;p&gt;Schneider Electric is aware of multiple vulnerabilities in the IGSS (Interactive Graphical SCADA&#13;
System) Data Server module.&#13;
The IGSS product is a state-of-the art SCADA system used for monitoring and controlling&#13;
industrial processes. The Data Server is a module with a TCP interface used by other modules&#13;
to access data of the SCADA System.&#13;
Failure to apply the remediations provided below may risk remote code execution, which could result in a variety of issues including disclosure of data and loss of control of the SCADA System with IGSS running in production mode.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Schneider Electric is aware of multiple vulnerabilities in the IGSS (Interactive Graphical SCADA&#13;
System) Data Server module.&#13;
The IGSS product is a state-of-the art SCADA system used for monitoring and controlling&#13;
industrial processes. The Data Server is a module with a TCP interface used by other modules&#13;
to access data of the SCADA System.&#13;
Failure to apply the remediations provided below may risk remote code execution, which could result in a variety of issues including disclosure of data and loss of control of the SCADA System with IGSS running in production mode.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/sevd-2022-039-01</guid>
    </item>
  </channel>
</rss>