    <item>
      <title>bdu:2022-04373</title>
      <link>https://cve.radiocsirt.org/vuln/bdu:2022-04373</link>
      <description>bdu:2022-04373</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/bdu:2022-04373</guid>
    </item>
    <item>
      <title>certfr-2022-avi-628 — De multiples vulnérabilités ont été découvertes dans les produits
Schneider Electric. Certaines d'entre elles permetten…</title>
      <link>https://cve.radiocsirt.org/vuln/certfr-2022-avi-628</link>
      <description>certfr-2022-avi-628</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/certfr-2022-avi-628</guid>
    </item>
    <item>
      <title>EUVD-2026-213809</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-213809</link>
      <description>EUVD-2026-213809</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-213809</guid>
    </item>
    <item>
      <title>fkie_cve-2022-2329</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2022-2329</link>
      <description>&lt;p&gt;A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073)&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073)&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2022-2329</guid>
    </item>
    <item>
      <title>GHSA-2384-wfr6-9j3j</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-2384-wfr6-9j3j</link>
      <description>&lt;p&gt;A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073)&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073)&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-2384-wfr6-9j3j</guid>
    </item>
    <item>
      <title>gsd-2022-2329</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2022-2329</link>
      <description>gsd-2022-2329</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2022-2329</guid>
    </item>
    <item>
      <title>SEVD-2022-102-01 — IGSS (Interactive Graphical SCADA System)</title>
      <link>https://cve.radiocsirt.org/vuln/sevd-2022-102-01</link>
      <description>&lt;p&gt;Schneider Electric is aware of a vulnerability in its Data Server module for the IGSS (Interactive Graphical SCADA System) product.&#13;
The IGSS product is a state-of-the art SCADA system used for monitoring and controlling industrial processes. The Data Server is a module with a TCP interface used by other modules to access data of the SCADA System.&#13;
Failure to apply the remediations provided below may risk remote code execution, which could result in a variety of issues including disclosure of data and loss of control of the SCADA System with IGSS running in production mode. July 12, 2022 Update: An additional vulnerability, CVE-2022-2329, was remediated with the released patch.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Schneider Electric is aware of a vulnerability in its Data Server module for the IGSS (Interactive Graphical SCADA System) product.&#13;
The IGSS product is a state-of-the art SCADA system used for monitoring and controlling industrial processes. The Data Server is a module with a TCP interface used by other modules to access data of the SCADA System.&#13;
Failure to apply the remediations provided below may risk remote code execution, which could result in a variety of issues including disclosure of data and loss of control of the SCADA System with IGSS running in production mode. July 12, 2022 Update: An additional vulnerability, CVE-2022-2329, was remediated with the released patch.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/sevd-2022-102-01</guid>