    <item>
      <title>bdu:2022-04578</title>
      <link>https://cve.radiocsirt.org/vuln/bdu:2022-04578</link>
      <description>bdu:2022-04578</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/bdu:2022-04578</guid>
    </item>
    <item>
      <title>EUVD-2026-175143</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-175143</link>
      <description>EUVD-2026-175143</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-175143</guid>
    </item>
    <item>
      <title>fkie_cve-2022-2302</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2022-2302</link>
      <description>&lt;p&gt;Multiple Lenze products of the cabinet series skip the password verification upon second login. After a user has been logged on to the device once, a remote attacker can get full access without knowledge of the password.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Multiple Lenze products of the cabinet series skip the password verification upon second login. After a user has been logged on to the device once, a remote attacker can get full access without knowledge of the password.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2022-2302</guid>
    </item>
    <item>
      <title>GHSA-78pc-4xg6-x467</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-78pc-4xg6-x467</link>
      <description>&lt;p&gt;Multiple Lenze products of the cabinet series skip the password verification upon second login. After a user has been logged on to the device once, a remote attacker can get full access without knowledge of the password.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Multiple Lenze products of the cabinet series skip the password verification upon second login. After a user has been logged on to the device once, a remote attacker can get full access without knowledge of the password.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-78pc-4xg6-x467</guid>
    </item>
    <item>
      <title>gsd-2022-2302</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2022-2302</link>
      <description>gsd-2022-2302</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2022-2302</guid>
    </item>
    <item>
      <title>VDE-2022-030 — Lenze: Vulnerability in the OPC-UA authentification connection in the firmware</title>
      <link>https://cve.radiocsirt.org/vuln/vde-2022-030</link>
      <description>&lt;p&gt;The machine controller of the cabinet series include an OPC-UA server which uses an user management to authenticate clients via anonymous or user/password authentication. If the user/password authentication is selected, password verification is skipped upon second login. As a result, cases occur in which users can establish communication without correct authentication. This vulnerability is not located in the OPC-UA protocol or server, but in the interface to the products firmware.&lt;/p&gt;
&lt;p&gt;This Security Advisory is only relevant for the following use cases:&lt;/p&gt;
&lt;p&gt;• the user management has been activated on the machine controller (is deactivated by default)&lt;/p&gt;
&lt;p&gt;• the OPC-UA Server is used&lt;/p&gt;
&lt;p&gt;• Data are transferred via a symbol configuration (is not available by default)&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;The machine controller of the cabinet series include an OPC-UA server which uses an user management to authenticate clients via anonymous or user/password authentication. If the user/password authentication is selected, password verification is skipped upon second login. As a result, cases occur in which users can establish communication without correct authentication. This vulnerability is not located in the OPC-UA protocol or server, but in the interface to the products firmware.&lt;/p&gt;
&lt;p&gt;This Security Advisory is only relevant for the following use cases:&lt;/p&gt;
&lt;p&gt;• the user management has been activated on the machine controller (is deactivated by default)&lt;/p&gt;
&lt;p&gt;• the OPC-UA Server is used&lt;/p&gt;
&lt;p&gt;• Data are transferred via a symbol configuration (is not available by default)&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/vde-2022-030</guid>