<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Mon, 05 Oct 2026 09:14:24 +0000</lastBuildDate>
    <item>
      <title>EUVD-2026-29663</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-29663</link>
      <description>EUVD-2026-29663</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-29663</guid>
    </item>
    <item>
      <title>fkie_cve-2021-37163</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2021-37163</link>
      <description>&lt;p&gt;An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released versions of software before Nexus Software 7.2.5.7. The device has two user accounts with passwords that are hardcoded.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released versions of software before Nexus Software 7.2.5.7. The device has two user accounts with passwords that are hardcoded.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2021-37163</guid>
    </item>
    <item>
      <title>GHSA-4f84-vrx5-rhj8</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-4f84-vrx5-rhj8</link>
      <description>&lt;p&gt;An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released versions of software before Nexus Software 7.2.5.7. The device has two user accounts with passwords that are hardcoded.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released versions of software before Nexus Software 7.2.5.7. The device has two user accounts with passwords that are hardcoded.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-4f84-vrx5-rhj8</guid>
    </item>
    <item>
      <title>gsd-2021-37163</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2021-37163</link>
      <description>gsd-2021-37163</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2021-37163</guid>
    </item>
    <item>
      <title>ICSMA-21-215-01 — Swisslog Healthcare Translogic PTS</title>
      <link>https://cve.radiocsirt.org/vuln/icsma-21-215-01</link>
      <description>&lt;p&gt;User and root accounts have hardcoded passwords that can be accessed remotely on the Nexus Control Panel. These accounts are enabled by default and cannot be turned off by native configuration of the system.CVE-2021-37163 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A user logged in using the default credentials can gain root access to the device, which allows permissions for all the functionalities of the device.CVE-2021-37167 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). A buffer overflow allows an attacker to overwrite an internal queue data structure, which could allow remote code execution.CVE-2021-37161 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A buffer overflow allows an attacker to overwrite an internal queue data structure, which could allow remote code execution.CVE-2021-37162 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A specially crafted message to the HMI may cause an overflow, which could allow remote code execution.CVE-2021-37165 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVS…&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;User and root accounts have hardcoded passwords that can be accessed remotely on the Nexus Control Panel. These accounts are enabled by default and cannot be turned off by native configuration of the system.CVE-2021-37163 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A user logged in using the default credentials can gain root access to the device, which allows permissions for all the functionalities of the device.CVE-2021-37167 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). A buffer overflow allows an attacker to overwrite an internal queue data structure, which could allow remote code execution.CVE-2021-37161 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A buffer overflow allows an attacker to overwrite an internal queue data structure, which could allow remote code execution.CVE-2021-37162 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A specially crafted message to the HMI may cause an overflow, which could allow remote code execution.CVE-2021-37165 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVS…&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsma-21-215-01</guid>
    </item>
  </channel>
</rss>
