    <item>
      <title>EUVD-2026-185277</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-185277</link>
      <description>EUVD-2026-185277</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-185277</guid>
    </item>
    <item>
      <title>fkie_cve-2021-34593</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2021-34593</link>
      <description>&lt;p&gt;In CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56 unauthenticated crafted invalid requests may result in several denial-of-service conditions. Running PLC programs may be stopped, memory may be leaked, or further communication clients may be blocked from accessing the PLC.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;In CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56 unauthenticated crafted invalid requests may result in several denial-of-service conditions. Running PLC programs may be stopped, memory may be leaked, or further communication clients may be blocked from accessing the PLC.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2021-34593</guid>
    </item>
    <item>
      <title>FSA-202601 — Several CODESYS vulnerabilities in Festo Automation Suite</title>
      <link>https://cve.radiocsirt.org/vuln/fsa-202601</link>
      <description>&lt;p&gt;Starting with Festo Automation Suite (FAS) version 2.8.0.138, the suite is delivered only with a connector to Codesys, rather than including Codesys directly. Prior to this version, Codesys was bundled within the FAS installation. From version 2.8.0.138 onwards, customers are required to download and install Codesys independently.&lt;/p&gt;
&lt;p&gt;This change impacts the handling of security vulnerabilities (CVEs) related to Codesys. Any Codesys-related security issues must now be addressed by the customer through their separate Codesys installation. The FAS itself includes only the connector component, which is maintained and updated within the suite.&lt;/p&gt;
&lt;p&gt;Please ensure that Codesys is kept up to date independently to mitigate any potential security risks associated with the Codesys software.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Starting with Festo Automation Suite (FAS) version 2.8.0.138, the suite is delivered only with a connector to Codesys, rather than including Codesys directly. Prior to this version, Codesys was bundled within the FAS installation. From version 2.8.0.138 onwards, customers are required to download and install Codesys independently.&lt;/p&gt;
&lt;p&gt;This change impacts the handling of security vulnerabilities (CVEs) related to Codesys. Any Codesys-related security issues must now be addressed by the customer through their separate Codesys installation. The FAS itself includes only the connector component, which is maintained and updated within the suite.&lt;/p&gt;
&lt;p&gt;Please ensure that Codesys is kept up to date independently to mitigate any potential security risks associated with the Codesys software.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fsa-202601</guid>
    </item>
    <item>
      <title>GHSA-mp42-p5v3-r5p6</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-mp42-p5v3-r5p6</link>
      <description>&lt;p&gt;In CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56 unauthenticated crafted invalid requests may result in several denial-of-service conditions. Running PLC programs may be stopped, memory may be leaked, or further communication clients may be blocked from accessing the PLC.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;In CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56 unauthenticated crafted invalid requests may result in several denial-of-service conditions. Running PLC programs may be stopped, memory may be leaked, or further communication clients may be blocked from accessing the PLC.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-mp42-p5v3-r5p6</guid>
    </item>
    <item>
      <title>gsd-2021-34593</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2021-34593</link>
      <description>gsd-2021-34593</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2021-34593</guid>
    </item>
    <item>
      <title>ICSA-26-076-01 — CODESYS in Festo Automation Suite</title>
      <link>https://cve.radiocsirt.org/vuln/icsa-26-076-01</link>
      <description>&lt;p&gt;Starting with Festo Automation Suite (FAS) version 2.8.0.138, the suite is delivered only with a connector to Codesys, rather than including Codesys directly. Prior to this version, Codesys was bundled within the FAS installation. From version 2.8.0.138 onwards, customers are required to download and install Codesys independently.&lt;/p&gt;
&lt;p&gt;This change impacts the handling of security vulnerabilities (CVEs) related to Codesys. Any Codesys-related security issues must now be addressed by the customer through their separate Codesys installation. The FAS itself includes only the connector component, which is maintained and updated within the suite.&lt;/p&gt;
&lt;p&gt;Please ensure that Codesys is kept up to date independently to mitigate any potential security risks associated with the Codesys software.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Starting with Festo Automation Suite (FAS) version 2.8.0.138, the suite is delivered only with a connector to Codesys, rather than including Codesys directly. Prior to this version, Codesys was bundled within the FAS installation. From version 2.8.0.138 onwards, customers are required to download and install Codesys independently.&lt;/p&gt;
&lt;p&gt;This change impacts the handling of security vulnerabilities (CVEs) related to Codesys. Any Codesys-related security issues must now be addressed by the customer through their separate Codesys installation. The FAS itself includes only the connector component, which is maintained and updated within the suite.&lt;/p&gt;
&lt;p&gt;Please ensure that Codesys is kept up to date independently to mitigate any potential security risks associated with the Codesys software.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsa-26-076-01</guid>
    </item>
    <item>
      <title>VDE-2021-049 — WAGO: Denial of Service Vulnerability in CODESYS Runtime 2.3</title>
      <link>https://cve.radiocsirt.org/vuln/vde-2021-049</link>
      <description>&lt;p&gt;In CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56 unauthenticated crafted invalid requests may result in several denial-of-service conditions. Running PLC programs may be stopped, memory may be leaked, or further communication clients may be blocked from accessing the PLC.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;In CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56 unauthenticated crafted invalid requests may result in several denial-of-service conditions. Running PLC programs may be stopped, memory may be leaked, or further communication clients may be blocked from accessing the PLC.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/vde-2021-049</guid>
    </item>
    <item>
      <title>VDE-2021-054 — Pilz: Multiple vulnerabilities in CODESYS V2 and V3 runtime system</title>
      <link>https://cve.radiocsirt.org/vuln/vde-2021-054</link>
      <description>&lt;p&gt;Several Pilz products use Versions V2 and V3 of the CODESYS runtime system from CODESYS GmbH, which enables the execution of IEC 61131-3 PLC programs. These runtime environments contain several vulnerabilities, which an attacker can exploit via the network. Successful exploitation of the vulnerabilities results in reduced availability and, in a worst case, to the insertion of program code.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Several Pilz products use Versions V2 and V3 of the CODESYS runtime system from CODESYS GmbH, which enables the execution of IEC 61131-3 PLC programs. These runtime environments contain several vulnerabilities, which an attacker can exploit via the network. Successful exploitation of the vulnerabilities results in reduced availability and, in a worst case, to the insertion of program code.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/vde-2021-054</guid>
    </item>
  </channel>