<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Sat, 03 Oct 2026 14:11:22 +0000</lastBuildDate>
    <item>
      <title>cnvd-2021-48139</title>
      <link>https://cve.radiocsirt.org/vuln/cnvd-2021-48139</link>
      <description>cnvd-2021-48139</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/cnvd-2021-48139</guid>
    </item>
    <item>
      <title>EUVD-2026-182945</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-182945</link>
      <description>EUVD-2026-182945</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-182945</guid>
    </item>
    <item>
      <title>fkie_cve-2021-33537</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2021-33537</link>
      <description>&lt;p&gt;In Weidmueller Industrial WLAN devices in multiple versions an exploitable remote code execution vulnerability exists in the iw_webs configuration parsing functionality. A specially crafted user name entry can cause an overflow of an error message buffer, resulting in remote code execution. An attacker can send commands while authenticated as a low privilege user to trigger this vulnerability.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;In Weidmueller Industrial WLAN devices in multiple versions an exploitable remote code execution vulnerability exists in the iw_webs configuration parsing functionality. A specially crafted user name entry can cause an overflow of an error message buffer, resulting in remote code execution. An attacker can send commands while authenticated as a low privilege user to trigger this vulnerability.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2021-33537</guid>
    </item>
    <item>
      <title>GHSA-j5r6-wf58-2j94</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-j5r6-wf58-2j94</link>
      <description>&lt;p&gt;In Weidmueller Industrial WLAN devices in multiple versions an exploitable remote code execution vulnerability exists in the iw_webs configuration parsing functionality. A specially crafted user name entry can cause an overflow of an error message buffer, resulting in remote code execution. An attacker can send commands while authenticated as a low privilege user to trigger this vulnerability.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;In Weidmueller Industrial WLAN devices in multiple versions an exploitable remote code execution vulnerability exists in the iw_webs configuration parsing functionality. A specially crafted user name entry can cause an overflow of an error message buffer, resulting in remote code execution. An attacker can send commands while authenticated as a low privilege user to trigger this vulnerability.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-j5r6-wf58-2j94</guid>
    </item>
    <item>
      <title>gsd-2021-33537</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2021-33537</link>
      <description>gsd-2021-33537</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2021-33537</guid>
    </item>
    <item>
      <title>VDE-2021-026 — Weidmueller: Multiple vulnerabilities in Industrial WLAN devices</title>
      <link>https://cve.radiocsirt.org/vuln/vde-2021-026</link>
      <description>&lt;p&gt;Multiple issues in Weidmueller Industrial WLAN devices have been found.&lt;/p&gt;
&lt;p&gt;Initial publication date: 2021-06-23
Update A publication date: 2021-07-02&lt;/p&gt;
&lt;p&gt;Update A&lt;/p&gt;
&lt;p&gt;CVE-2021-33534&lt;/p&gt;
&lt;p&gt;CVSS: 7.2 (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H)
Description: An exploitable command injection vulnerability exists in the hostname functionality of Weidmueller Industrial WLAN devices. A specially crafted entry to network configuration information can cause execution of arbitrary system commands, resulting in full control of the device. An attacker can send various requests while authenticated as a high privilege user to trigger this vulnerability.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Multiple issues in Weidmueller Industrial WLAN devices have been found.&lt;/p&gt;
&lt;p&gt;Initial publication date: 2021-06-23
Update A publication date: 2021-07-02&lt;/p&gt;
&lt;p&gt;Update A&lt;/p&gt;
&lt;p&gt;CVE-2021-33534&lt;/p&gt;
&lt;p&gt;CVSS: 7.2 (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H)
Description: An exploitable command injection vulnerability exists in the hostname functionality of Weidmueller Industrial WLAN devices. A specially crafted entry to network configuration information can cause execution of arbitrary system commands, resulting in full control of the device. An attacker can send various requests while authenticated as a high privilege user to trigger this vulnerability.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/vde-2021-026</guid>
    </item>
  </channel>
</rss>
